Decreased visual acuity resulting from glistening and sub-surface nano-glistening formation in intraocular lenses: A retrospective analysis of 5 cases

BACKGROUND: To report on five patients with decreased visual acuity due to glistening and severe sub-surface nano-glistening (SSNG) formation within their intraocular lenses (IOLs). DESIGN: Case reports and analysis of extracted IOLs. PARTICIPANTS AND SAMPLES: We report improved visual acuity when I...

Descripción completa

Detalles Bibliográficos
Autores principales: Matsushima, Hiroyuki, Nagata, Mayumi, Katsuki, Yoko, Ota, Ichiro, Miyake, Kensaku, Beiko, George H.H., Grzybowski, Andrzej
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4625192/
https://www.ncbi.nlm.nih.gov/pubmed/26586975
http://dx.doi.org/10.1016/j.sjopt.2015.07.001
_version_ 1782397952549978112
author Matsushima, Hiroyuki
Nagata, Mayumi
Katsuki, Yoko
Ota, Ichiro
Miyake, Kensaku
Beiko, George H.H.
Grzybowski, Andrzej
author_facet Matsushima, Hiroyuki
Nagata, Mayumi
Katsuki, Yoko
Ota, Ichiro
Miyake, Kensaku
Beiko, George H.H.
Grzybowski, Andrzej
author_sort Matsushima, Hiroyuki
collection PubMed
description BACKGROUND: To report on five patients with decreased visual acuity due to glistening and severe sub-surface nano-glistening (SSNG) formation within their intraocular lenses (IOLs). DESIGN: Case reports and analysis of extracted IOLs. PARTICIPANTS AND SAMPLES: We report improved visual acuity when IOLs with severe glistening and SSNG were exchanged for clear IOLs in five patients. METHODS: Case reports. MAIN OUTCOME MEASURES: The main outcome measure was visual acuity. The secondary outcome measure was light transmission. Explanted IOLs were subjected to investigation. Pre- and postoperative slit lamp images of the anterior eye and microscopic images of the extracted IOLs were taken and compared. Light transmission of the IOL was measured using a double beam type spectrophotometer. An integrated value of the percentage light transmittance in the visible light spectrum was calculated. RESULTS: We report on five patients whose visual acuity improved when IOLs were exchanged because of severe glistening and SSNG. All of the affected IOLs were MA60BM (Alcon, Forth Wroth Texas, USA) and the original implantation had occurred over a range of 6–15 years prior to the IOL exchange. Light transmission was decreased in all affected lenses compared to a similar control IOL. CONCLUSIONS: Although only a few reports of cases in which glistening and SSNG have progressed to the level of decreased visual function have been published, the likelihood is that this phenomena will increase as the severity and incidence of these inclusions have been shown to increase with time. Appropriate evaluations of visual function in such patients are needed and consideration should be given to IOL exchange in symptomatic patients.
format Online
Article
Text
id pubmed-4625192
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-46251922015-11-19 Decreased visual acuity resulting from glistening and sub-surface nano-glistening formation in intraocular lenses: A retrospective analysis of 5 cases Matsushima, Hiroyuki Nagata, Mayumi Katsuki, Yoko Ota, Ichiro Miyake, Kensaku Beiko, George H.H. Grzybowski, Andrzej Saudi J Ophthalmol Original Article BACKGROUND: To report on five patients with decreased visual acuity due to glistening and severe sub-surface nano-glistening (SSNG) formation within their intraocular lenses (IOLs). DESIGN: Case reports and analysis of extracted IOLs. PARTICIPANTS AND SAMPLES: We report improved visual acuity when IOLs with severe glistening and SSNG were exchanged for clear IOLs in five patients. METHODS: Case reports. MAIN OUTCOME MEASURES: The main outcome measure was visual acuity. The secondary outcome measure was light transmission. Explanted IOLs were subjected to investigation. Pre- and postoperative slit lamp images of the anterior eye and microscopic images of the extracted IOLs were taken and compared. Light transmission of the IOL was measured using a double beam type spectrophotometer. An integrated value of the percentage light transmittance in the visible light spectrum was calculated. RESULTS: We report on five patients whose visual acuity improved when IOLs were exchanged because of severe glistening and SSNG. All of the affected IOLs were MA60BM (Alcon, Forth Wroth Texas, USA) and the original implantation had occurred over a range of 6–15 years prior to the IOL exchange. Light transmission was decreased in all affected lenses compared to a similar control IOL. CONCLUSIONS: Although only a few reports of cases in which glistening and SSNG have progressed to the level of decreased visual function have been published, the likelihood is that this phenomena will increase as the severity and incidence of these inclusions have been shown to increase with time. Appropriate evaluations of visual function in such patients are needed and consideration should be given to IOL exchange in symptomatic patients. Elsevier 2015 2015-07-29 /pmc/articles/PMC4625192/ /pubmed/26586975 http://dx.doi.org/10.1016/j.sjopt.2015.07.001 Text en © 2015 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Matsushima, Hiroyuki
Nagata, Mayumi
Katsuki, Yoko
Ota, Ichiro
Miyake, Kensaku
Beiko, George H.H.
Grzybowski, Andrzej
Decreased visual acuity resulting from glistening and sub-surface nano-glistening formation in intraocular lenses: A retrospective analysis of 5 cases
title Decreased visual acuity resulting from glistening and sub-surface nano-glistening formation in intraocular lenses: A retrospective analysis of 5 cases
title_full Decreased visual acuity resulting from glistening and sub-surface nano-glistening formation in intraocular lenses: A retrospective analysis of 5 cases
title_fullStr Decreased visual acuity resulting from glistening and sub-surface nano-glistening formation in intraocular lenses: A retrospective analysis of 5 cases
title_full_unstemmed Decreased visual acuity resulting from glistening and sub-surface nano-glistening formation in intraocular lenses: A retrospective analysis of 5 cases
title_short Decreased visual acuity resulting from glistening and sub-surface nano-glistening formation in intraocular lenses: A retrospective analysis of 5 cases
title_sort decreased visual acuity resulting from glistening and sub-surface nano-glistening formation in intraocular lenses: a retrospective analysis of 5 cases
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4625192/
https://www.ncbi.nlm.nih.gov/pubmed/26586975
http://dx.doi.org/10.1016/j.sjopt.2015.07.001
work_keys_str_mv AT matsushimahiroyuki decreasedvisualacuityresultingfromglisteningandsubsurfacenanoglisteningformationinintraocularlensesaretrospectiveanalysisof5cases
AT nagatamayumi decreasedvisualacuityresultingfromglisteningandsubsurfacenanoglisteningformationinintraocularlensesaretrospectiveanalysisof5cases
AT katsukiyoko decreasedvisualacuityresultingfromglisteningandsubsurfacenanoglisteningformationinintraocularlensesaretrospectiveanalysisof5cases
AT otaichiro decreasedvisualacuityresultingfromglisteningandsubsurfacenanoglisteningformationinintraocularlensesaretrospectiveanalysisof5cases
AT miyakekensaku decreasedvisualacuityresultingfromglisteningandsubsurfacenanoglisteningformationinintraocularlensesaretrospectiveanalysisof5cases
AT beikogeorgehh decreasedvisualacuityresultingfromglisteningandsubsurfacenanoglisteningformationinintraocularlensesaretrospectiveanalysisof5cases
AT grzybowskiandrzej decreasedvisualacuityresultingfromglisteningandsubsurfacenanoglisteningformationinintraocularlensesaretrospectiveanalysisof5cases