Cargando…

A Membrane-Based Electro-Separation Method (MBES) for Sample Clean-Up and Norovirus Concentration

Noroviruses are the leading cause of acute gastroenteritis and foodborne illnesses in the United States. Enhanced methods for detecting noroviruses in food matrices are needed as current methods are complex, labor intensive and insensitive, often resulting in inhibition of downstream molecular detec...

Descripción completa

Detalles Bibliográficos
Autores principales: Kang, Wei, Cannon, Jennifer L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4625962/
https://www.ncbi.nlm.nih.gov/pubmed/26513464
http://dx.doi.org/10.1371/journal.pone.0141484
_version_ 1782398054429622272
author Kang, Wei
Cannon, Jennifer L.
author_facet Kang, Wei
Cannon, Jennifer L.
author_sort Kang, Wei
collection PubMed
description Noroviruses are the leading cause of acute gastroenteritis and foodborne illnesses in the United States. Enhanced methods for detecting noroviruses in food matrices are needed as current methods are complex, labor intensive and insensitive, often resulting in inhibition of downstream molecular detection and inefficient recovery. Membrane-based electro-separation (MBES) is a technique to exchange charged particles through a size-specific dialysis membrane from one solution to another using electric current as the driving force. Norovirus has a net negative surface charge in a neutrally buffered environment, so when placed in an electric field, it moves towards the anode. It can then be separated from the cathodic compartment where the sample is placed and then collected in the anodic compartment for downstream detection. In this study, a MBES-based system was designed, developed and evaluated for concentrating and recovering murine norovirus (MNV-1) from phosphate buffer. As high as 30.8% MNV-1 migrated from the 3.5 ml sample chamber to the 1.5 ml collection chamber across a 1 μm separation membrane when 20 V was applied for 30 min using 20 mM sodium phosphate with 0.01% SDS (pH 7.5) as the electrolyte. In optimization of the method, weak applied voltage (20 V), moderate duration (30 min), and low ionic strength electrolytes with SDS addition were needed to increase virus movement efficacy. The electric field strength of the system was the key factor to enhance virus movement, which could only be improved by shortening the electrodes distance, instead of increasing system applied voltage because of virus stability. This study successfully demonstrated the norovirus mobility in an electric field and migration across a size-specific membrane barrier in sodium phosphate electrolyte. With further modification and validation in food matrixes, a novel, quick, and cost-effective sample clean-up technique might be developed to separate norovirus particles from food matrices by electric force.
format Online
Article
Text
id pubmed-4625962
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-46259622015-11-06 A Membrane-Based Electro-Separation Method (MBES) for Sample Clean-Up and Norovirus Concentration Kang, Wei Cannon, Jennifer L. PLoS One Research Article Noroviruses are the leading cause of acute gastroenteritis and foodborne illnesses in the United States. Enhanced methods for detecting noroviruses in food matrices are needed as current methods are complex, labor intensive and insensitive, often resulting in inhibition of downstream molecular detection and inefficient recovery. Membrane-based electro-separation (MBES) is a technique to exchange charged particles through a size-specific dialysis membrane from one solution to another using electric current as the driving force. Norovirus has a net negative surface charge in a neutrally buffered environment, so when placed in an electric field, it moves towards the anode. It can then be separated from the cathodic compartment where the sample is placed and then collected in the anodic compartment for downstream detection. In this study, a MBES-based system was designed, developed and evaluated for concentrating and recovering murine norovirus (MNV-1) from phosphate buffer. As high as 30.8% MNV-1 migrated from the 3.5 ml sample chamber to the 1.5 ml collection chamber across a 1 μm separation membrane when 20 V was applied for 30 min using 20 mM sodium phosphate with 0.01% SDS (pH 7.5) as the electrolyte. In optimization of the method, weak applied voltage (20 V), moderate duration (30 min), and low ionic strength electrolytes with SDS addition were needed to increase virus movement efficacy. The electric field strength of the system was the key factor to enhance virus movement, which could only be improved by shortening the electrodes distance, instead of increasing system applied voltage because of virus stability. This study successfully demonstrated the norovirus mobility in an electric field and migration across a size-specific membrane barrier in sodium phosphate electrolyte. With further modification and validation in food matrixes, a novel, quick, and cost-effective sample clean-up technique might be developed to separate norovirus particles from food matrices by electric force. Public Library of Science 2015-10-29 /pmc/articles/PMC4625962/ /pubmed/26513464 http://dx.doi.org/10.1371/journal.pone.0141484 Text en © 2015 Kang, Cannon http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Kang, Wei
Cannon, Jennifer L.
A Membrane-Based Electro-Separation Method (MBES) for Sample Clean-Up and Norovirus Concentration
title A Membrane-Based Electro-Separation Method (MBES) for Sample Clean-Up and Norovirus Concentration
title_full A Membrane-Based Electro-Separation Method (MBES) for Sample Clean-Up and Norovirus Concentration
title_fullStr A Membrane-Based Electro-Separation Method (MBES) for Sample Clean-Up and Norovirus Concentration
title_full_unstemmed A Membrane-Based Electro-Separation Method (MBES) for Sample Clean-Up and Norovirus Concentration
title_short A Membrane-Based Electro-Separation Method (MBES) for Sample Clean-Up and Norovirus Concentration
title_sort membrane-based electro-separation method (mbes) for sample clean-up and norovirus concentration
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4625962/
https://www.ncbi.nlm.nih.gov/pubmed/26513464
http://dx.doi.org/10.1371/journal.pone.0141484
work_keys_str_mv AT kangwei amembranebasedelectroseparationmethodmbesforsamplecleanupandnorovirusconcentration
AT cannonjenniferl amembranebasedelectroseparationmethodmbesforsamplecleanupandnorovirusconcentration
AT kangwei membranebasedelectroseparationmethodmbesforsamplecleanupandnorovirusconcentration
AT cannonjenniferl membranebasedelectroseparationmethodmbesforsamplecleanupandnorovirusconcentration