Cargando…

Prevalence and Molecular Characteristics of Waterborne Pathogen Legionella in Industrial Cooling Tower Environments

Cooling towers are a source of Legionnaires’ disease. It is important from a public health perspective to survey industrial cooling towers for the presence of Legionella. Prospective surveillance of the extent of Legionella pollution was conducted at factories in Shijiazhuang, China between March 20...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Lijie, Qin, Tian, Li, Yun, Zhou, Haijian, Song, Hongmei, Ren, Hongyu, Li, Liping, Li, Yongguang, Zhao, Dong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4626988/
https://www.ncbi.nlm.nih.gov/pubmed/26473896
http://dx.doi.org/10.3390/ijerph121012605
_version_ 1782398197941927936
author Li, Lijie
Qin, Tian
Li, Yun
Zhou, Haijian
Song, Hongmei
Ren, Hongyu
Li, Liping
Li, Yongguang
Zhao, Dong
author_facet Li, Lijie
Qin, Tian
Li, Yun
Zhou, Haijian
Song, Hongmei
Ren, Hongyu
Li, Liping
Li, Yongguang
Zhao, Dong
author_sort Li, Lijie
collection PubMed
description Cooling towers are a source of Legionnaires’ disease. It is important from a public health perspective to survey industrial cooling towers for the presence of Legionella. Prospective surveillance of the extent of Legionella pollution was conducted at factories in Shijiazhuang, China between March 2011 and September 2012. Overall, 35.7% of 255 industrial cooling tower water samples showed Legionella-positive, and their concentrations ranged from 100 Colony-Forming Units (CFU)/liter to 88,000 CFU/liter, with an average concentration of 9100 CFU/liter. A total of 121 isolates were obtained. All isolates were L. pneumophila, and the isolated serogroups included serogroups 1 (68 isolates, 56.2%), 6 (25, 20.7%), 5 (12, 9.9%), 8 (8, 6.6%), 3 (6, 5.0%) and 9 (2, 1.6%). All 121 isolates were analyzed by pulsed-field gel electrophoresis (PFGE) and 64 different patterns were obtained. All 121 isolates were analyzed sequence-based typing (SBT), a full 7-allele profile was obtained from 117 isolates. One hundred and seventeen isolates were divided into 49 sequence types. Two virulence genes, lvh and rtxA, are analyzed by polymerase chain reaction (PCR). 92.6% (112/121) and 98.3% (119/121) isolates carried lvh and rtxA respectively and 90.9% (110/121) of tested isolates carried both genes. Our results demonstrated high prevalence and genetic polymorphism of L. pneumophila in industrial cooling tower environments in Shijiazhang, China, and the SBT and virulence gene PCR results suggested that the isolates were pathogenic. Improved control and prevention strategies are urgently needed.
format Online
Article
Text
id pubmed-4626988
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-46269882015-11-12 Prevalence and Molecular Characteristics of Waterborne Pathogen Legionella in Industrial Cooling Tower Environments Li, Lijie Qin, Tian Li, Yun Zhou, Haijian Song, Hongmei Ren, Hongyu Li, Liping Li, Yongguang Zhao, Dong Int J Environ Res Public Health Article Cooling towers are a source of Legionnaires’ disease. It is important from a public health perspective to survey industrial cooling towers for the presence of Legionella. Prospective surveillance of the extent of Legionella pollution was conducted at factories in Shijiazhuang, China between March 2011 and September 2012. Overall, 35.7% of 255 industrial cooling tower water samples showed Legionella-positive, and their concentrations ranged from 100 Colony-Forming Units (CFU)/liter to 88,000 CFU/liter, with an average concentration of 9100 CFU/liter. A total of 121 isolates were obtained. All isolates were L. pneumophila, and the isolated serogroups included serogroups 1 (68 isolates, 56.2%), 6 (25, 20.7%), 5 (12, 9.9%), 8 (8, 6.6%), 3 (6, 5.0%) and 9 (2, 1.6%). All 121 isolates were analyzed by pulsed-field gel electrophoresis (PFGE) and 64 different patterns were obtained. All 121 isolates were analyzed sequence-based typing (SBT), a full 7-allele profile was obtained from 117 isolates. One hundred and seventeen isolates were divided into 49 sequence types. Two virulence genes, lvh and rtxA, are analyzed by polymerase chain reaction (PCR). 92.6% (112/121) and 98.3% (119/121) isolates carried lvh and rtxA respectively and 90.9% (110/121) of tested isolates carried both genes. Our results demonstrated high prevalence and genetic polymorphism of L. pneumophila in industrial cooling tower environments in Shijiazhang, China, and the SBT and virulence gene PCR results suggested that the isolates were pathogenic. Improved control and prevention strategies are urgently needed. MDPI 2015-10-12 2015-10 /pmc/articles/PMC4626988/ /pubmed/26473896 http://dx.doi.org/10.3390/ijerph121012605 Text en © 2015 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Li, Lijie
Qin, Tian
Li, Yun
Zhou, Haijian
Song, Hongmei
Ren, Hongyu
Li, Liping
Li, Yongguang
Zhao, Dong
Prevalence and Molecular Characteristics of Waterborne Pathogen Legionella in Industrial Cooling Tower Environments
title Prevalence and Molecular Characteristics of Waterborne Pathogen Legionella in Industrial Cooling Tower Environments
title_full Prevalence and Molecular Characteristics of Waterborne Pathogen Legionella in Industrial Cooling Tower Environments
title_fullStr Prevalence and Molecular Characteristics of Waterborne Pathogen Legionella in Industrial Cooling Tower Environments
title_full_unstemmed Prevalence and Molecular Characteristics of Waterborne Pathogen Legionella in Industrial Cooling Tower Environments
title_short Prevalence and Molecular Characteristics of Waterborne Pathogen Legionella in Industrial Cooling Tower Environments
title_sort prevalence and molecular characteristics of waterborne pathogen legionella in industrial cooling tower environments
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4626988/
https://www.ncbi.nlm.nih.gov/pubmed/26473896
http://dx.doi.org/10.3390/ijerph121012605
work_keys_str_mv AT lilijie prevalenceandmolecularcharacteristicsofwaterbornepathogenlegionellainindustrialcoolingtowerenvironments
AT qintian prevalenceandmolecularcharacteristicsofwaterbornepathogenlegionellainindustrialcoolingtowerenvironments
AT liyun prevalenceandmolecularcharacteristicsofwaterbornepathogenlegionellainindustrialcoolingtowerenvironments
AT zhouhaijian prevalenceandmolecularcharacteristicsofwaterbornepathogenlegionellainindustrialcoolingtowerenvironments
AT songhongmei prevalenceandmolecularcharacteristicsofwaterbornepathogenlegionellainindustrialcoolingtowerenvironments
AT renhongyu prevalenceandmolecularcharacteristicsofwaterbornepathogenlegionellainindustrialcoolingtowerenvironments
AT liliping prevalenceandmolecularcharacteristicsofwaterbornepathogenlegionellainindustrialcoolingtowerenvironments
AT liyongguang prevalenceandmolecularcharacteristicsofwaterbornepathogenlegionellainindustrialcoolingtowerenvironments
AT zhaodong prevalenceandmolecularcharacteristicsofwaterbornepathogenlegionellainindustrialcoolingtowerenvironments