Cargando…
Validation of a wireless dry electrode system for electroencephalography
BACKGROUND: Electroencephalography (EEG) is a widely used neuroimaging technique with applications in healthcare, research, assessment, treatment, and neurorehabilitation. Conventional EEG systems require extensive setup time, expensive equipment, and expertise to utilize and therefore are often lim...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4628242/ https://www.ncbi.nlm.nih.gov/pubmed/26520574 http://dx.doi.org/10.1186/s12984-015-0089-2 |
_version_ | 1782398411630182400 |
---|---|
author | Wyckoff, Sarah N Sherlin, Leslie H Ford, Noel Larson Dalke, Dale |
author_facet | Wyckoff, Sarah N Sherlin, Leslie H Ford, Noel Larson Dalke, Dale |
author_sort | Wyckoff, Sarah N |
collection | PubMed |
description | BACKGROUND: Electroencephalography (EEG) is a widely used neuroimaging technique with applications in healthcare, research, assessment, treatment, and neurorehabilitation. Conventional EEG systems require extensive setup time, expensive equipment, and expertise to utilize and therefore are often limited to clinical or laboratory settings. Technological advancements have made it possible to develop wireless EEG systems with dry electrodes to reduce many of these barriers. However, due to the lack of homogeneity in hardware, electrode evaluation, and methodological procedures the clinical acceptance of these systems has been limited. METHODS: In this investigation the validity of a wireless dry electrode system compared to a conventional wet electrode system was assessed, while addressing methodological limitations. In Experiment 1, the signal output of both EEG systems was examined at Fz, C3, Cz, C4, and Pz using a conductive head model and generated test signals at 2.5 Hz, 10 Hz, and 39 Hz. In Experiment 2, two-minutes of eyes-closed and eyes-open EEG data was recorded simultaneously with both devices from the adjacent electrode sites in a sample of healthy adults. RESULTS: Between group effects and frequency*device and electrode*device interactions were assessed using a mixed ANOVA for the simulated and in vivo signal output, producing no significant effects . Bivariate correlation coefficients were calculated to assess the relationship between electrode pairs during the simultaneous in vivo recordings, indicating a significant positive relationship (all p's < .05) and larger correlation coefficients (r > ± 0.5) between the dry and wet electrode signal amplitude were observed for theta, alpha, beta 1, beta 2, beta 3, and gamma in both the eyes-closed and eyes-open conditions. CONCLUSIONS: This report demonstrates preliminary but compelling evidence that EEG data recorded from the wireless dry electrode system is comparable to data recorded from a conventional system. Small correlation values in delta activity were discussed in relation to minor differences in hardware filter settings, variation in electrode placement, and participant artifacts observer during the simultaneous EEG recordings. Study limitations and impact of this research on neurorehabilitation were discussed. |
format | Online Article Text |
id | pubmed-4628242 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-46282422015-11-01 Validation of a wireless dry electrode system for electroencephalography Wyckoff, Sarah N Sherlin, Leslie H Ford, Noel Larson Dalke, Dale J Neuroeng Rehabil Research BACKGROUND: Electroencephalography (EEG) is a widely used neuroimaging technique with applications in healthcare, research, assessment, treatment, and neurorehabilitation. Conventional EEG systems require extensive setup time, expensive equipment, and expertise to utilize and therefore are often limited to clinical or laboratory settings. Technological advancements have made it possible to develop wireless EEG systems with dry electrodes to reduce many of these barriers. However, due to the lack of homogeneity in hardware, electrode evaluation, and methodological procedures the clinical acceptance of these systems has been limited. METHODS: In this investigation the validity of a wireless dry electrode system compared to a conventional wet electrode system was assessed, while addressing methodological limitations. In Experiment 1, the signal output of both EEG systems was examined at Fz, C3, Cz, C4, and Pz using a conductive head model and generated test signals at 2.5 Hz, 10 Hz, and 39 Hz. In Experiment 2, two-minutes of eyes-closed and eyes-open EEG data was recorded simultaneously with both devices from the adjacent electrode sites in a sample of healthy adults. RESULTS: Between group effects and frequency*device and electrode*device interactions were assessed using a mixed ANOVA for the simulated and in vivo signal output, producing no significant effects . Bivariate correlation coefficients were calculated to assess the relationship between electrode pairs during the simultaneous in vivo recordings, indicating a significant positive relationship (all p's < .05) and larger correlation coefficients (r > ± 0.5) between the dry and wet electrode signal amplitude were observed for theta, alpha, beta 1, beta 2, beta 3, and gamma in both the eyes-closed and eyes-open conditions. CONCLUSIONS: This report demonstrates preliminary but compelling evidence that EEG data recorded from the wireless dry electrode system is comparable to data recorded from a conventional system. Small correlation values in delta activity were discussed in relation to minor differences in hardware filter settings, variation in electrode placement, and participant artifacts observer during the simultaneous EEG recordings. Study limitations and impact of this research on neurorehabilitation were discussed. BioMed Central 2015-10-31 /pmc/articles/PMC4628242/ /pubmed/26520574 http://dx.doi.org/10.1186/s12984-015-0089-2 Text en © Wyckoff et al. 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Wyckoff, Sarah N Sherlin, Leslie H Ford, Noel Larson Dalke, Dale Validation of a wireless dry electrode system for electroencephalography |
title | Validation of a wireless dry electrode system for electroencephalography |
title_full | Validation of a wireless dry electrode system for electroencephalography |
title_fullStr | Validation of a wireless dry electrode system for electroencephalography |
title_full_unstemmed | Validation of a wireless dry electrode system for electroencephalography |
title_short | Validation of a wireless dry electrode system for electroencephalography |
title_sort | validation of a wireless dry electrode system for electroencephalography |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4628242/ https://www.ncbi.nlm.nih.gov/pubmed/26520574 http://dx.doi.org/10.1186/s12984-015-0089-2 |
work_keys_str_mv | AT wyckoffsarahn validationofawirelessdryelectrodesystemforelectroencephalography AT sherlinleslieh validationofawirelessdryelectrodesystemforelectroencephalography AT fordnoellarson validationofawirelessdryelectrodesystemforelectroencephalography AT dalkedale validationofawirelessdryelectrodesystemforelectroencephalography |