Cargando…

Gadolinium free cardiovascular magnetic resonance with 2-point Cine balanced steady state free precession

BACKGROUND: Cardiovascular magnetic resonance (CMR) of ventricular structure and function is widely performed using cine balanced steady state free precession (bSSFP) MRI. The bSSFP signal of myocardium is weighted by magnetization transfer (MT) and T1/T2-relaxation times. In edematous and fibrotic...

Descripción completa

Detalles Bibliográficos
Autores principales: Stromp, Tori A., Leung, Steve W., Andres, Kristin N., Jing, Linyuan, Fornwalt, Brandon K., Charnigo, Richard J., Sorrell, Vincent L., Vandsburger, Moriel H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4628395/
https://www.ncbi.nlm.nih.gov/pubmed/26520782
http://dx.doi.org/10.1186/s12968-015-0194-1
_version_ 1782398446847655936
author Stromp, Tori A.
Leung, Steve W.
Andres, Kristin N.
Jing, Linyuan
Fornwalt, Brandon K.
Charnigo, Richard J.
Sorrell, Vincent L.
Vandsburger, Moriel H.
author_facet Stromp, Tori A.
Leung, Steve W.
Andres, Kristin N.
Jing, Linyuan
Fornwalt, Brandon K.
Charnigo, Richard J.
Sorrell, Vincent L.
Vandsburger, Moriel H.
author_sort Stromp, Tori A.
collection PubMed
description BACKGROUND: Cardiovascular magnetic resonance (CMR) of ventricular structure and function is widely performed using cine balanced steady state free precession (bSSFP) MRI. The bSSFP signal of myocardium is weighted by magnetization transfer (MT) and T1/T2-relaxation times. In edematous and fibrotic tissues, increased T2 and reduced MT lead to increased signal intensity on images acquired with high excitation flip angles. We hypothesized that acquisition of two differentially MT-weighted bSSFP images (termed 2-point bSSFP) can identify tissue that would enhance with gadolinium similar to standard of care late gadolinium enhancement (LGE). METHODS: Cine bSSFP images (flip angles of 5° and 45°) and native-T1 and T2 maps were acquired in one mid-ventricular slice in 47 patients referred for CMR and 10 healthy controls. Afterwards, LGE images and post-contrast T1 maps were acquired and gadolinium partition coefficient (GPC) was calculated. Maps of ΔS/S(o) were calculated as (S(45)-S(5))/S(5)*100 (%), where S(flip_angle) is the voxel signal intensity. RESULTS: Twenty three patients demonstrated areas of myocardial hyper-enhancement with LGE. In enhanced regions, ΔS/S(o), native-T1, T2, and GPC were heightened (p < 0.05 vs. non-enhanced tissues). ΔS/S(o), native-T1, and T2 all demonstrated association with GPC, however the association was strongest for ΔS/S(o). Bland-Altman analysis revealed a slight bias towards larger volume of enhancement with ΔS/S(o) compared to LGE, and similar transmurality. Subjective analysis with 2-blinded expert readers revealed agreement between ΔS/S(o) and LGE of 73.4 %, with false positive detection of 16.7 % and false negative detection of 15.2 %. CONCLUSIONS: Gadolinium free 2-point bSSFP identified tissue that enhances at LGE with strong association to GPC. Our results suggest that with further development, MT-weighted CMR could be used similar to LGE for diagnostic imaging. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12968-015-0194-1) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-4628395
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-46283952015-11-03 Gadolinium free cardiovascular magnetic resonance with 2-point Cine balanced steady state free precession Stromp, Tori A. Leung, Steve W. Andres, Kristin N. Jing, Linyuan Fornwalt, Brandon K. Charnigo, Richard J. Sorrell, Vincent L. Vandsburger, Moriel H. J Cardiovasc Magn Reson Research BACKGROUND: Cardiovascular magnetic resonance (CMR) of ventricular structure and function is widely performed using cine balanced steady state free precession (bSSFP) MRI. The bSSFP signal of myocardium is weighted by magnetization transfer (MT) and T1/T2-relaxation times. In edematous and fibrotic tissues, increased T2 and reduced MT lead to increased signal intensity on images acquired with high excitation flip angles. We hypothesized that acquisition of two differentially MT-weighted bSSFP images (termed 2-point bSSFP) can identify tissue that would enhance with gadolinium similar to standard of care late gadolinium enhancement (LGE). METHODS: Cine bSSFP images (flip angles of 5° and 45°) and native-T1 and T2 maps were acquired in one mid-ventricular slice in 47 patients referred for CMR and 10 healthy controls. Afterwards, LGE images and post-contrast T1 maps were acquired and gadolinium partition coefficient (GPC) was calculated. Maps of ΔS/S(o) were calculated as (S(45)-S(5))/S(5)*100 (%), where S(flip_angle) is the voxel signal intensity. RESULTS: Twenty three patients demonstrated areas of myocardial hyper-enhancement with LGE. In enhanced regions, ΔS/S(o), native-T1, T2, and GPC were heightened (p < 0.05 vs. non-enhanced tissues). ΔS/S(o), native-T1, and T2 all demonstrated association with GPC, however the association was strongest for ΔS/S(o). Bland-Altman analysis revealed a slight bias towards larger volume of enhancement with ΔS/S(o) compared to LGE, and similar transmurality. Subjective analysis with 2-blinded expert readers revealed agreement between ΔS/S(o) and LGE of 73.4 %, with false positive detection of 16.7 % and false negative detection of 15.2 %. CONCLUSIONS: Gadolinium free 2-point bSSFP identified tissue that enhances at LGE with strong association to GPC. Our results suggest that with further development, MT-weighted CMR could be used similar to LGE for diagnostic imaging. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12968-015-0194-1) contains supplementary material, which is available to authorized users. BioMed Central 2015-10-29 /pmc/articles/PMC4628395/ /pubmed/26520782 http://dx.doi.org/10.1186/s12968-015-0194-1 Text en © Stromp et al. 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Stromp, Tori A.
Leung, Steve W.
Andres, Kristin N.
Jing, Linyuan
Fornwalt, Brandon K.
Charnigo, Richard J.
Sorrell, Vincent L.
Vandsburger, Moriel H.
Gadolinium free cardiovascular magnetic resonance with 2-point Cine balanced steady state free precession
title Gadolinium free cardiovascular magnetic resonance with 2-point Cine balanced steady state free precession
title_full Gadolinium free cardiovascular magnetic resonance with 2-point Cine balanced steady state free precession
title_fullStr Gadolinium free cardiovascular magnetic resonance with 2-point Cine balanced steady state free precession
title_full_unstemmed Gadolinium free cardiovascular magnetic resonance with 2-point Cine balanced steady state free precession
title_short Gadolinium free cardiovascular magnetic resonance with 2-point Cine balanced steady state free precession
title_sort gadolinium free cardiovascular magnetic resonance with 2-point cine balanced steady state free precession
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4628395/
https://www.ncbi.nlm.nih.gov/pubmed/26520782
http://dx.doi.org/10.1186/s12968-015-0194-1
work_keys_str_mv AT stromptoria gadoliniumfreecardiovascularmagneticresonancewith2pointcinebalancedsteadystatefreeprecession
AT leungstevew gadoliniumfreecardiovascularmagneticresonancewith2pointcinebalancedsteadystatefreeprecession
AT andreskristinn gadoliniumfreecardiovascularmagneticresonancewith2pointcinebalancedsteadystatefreeprecession
AT jinglinyuan gadoliniumfreecardiovascularmagneticresonancewith2pointcinebalancedsteadystatefreeprecession
AT fornwaltbrandonk gadoliniumfreecardiovascularmagneticresonancewith2pointcinebalancedsteadystatefreeprecession
AT charnigorichardj gadoliniumfreecardiovascularmagneticresonancewith2pointcinebalancedsteadystatefreeprecession
AT sorrellvincentl gadoliniumfreecardiovascularmagneticresonancewith2pointcinebalancedsteadystatefreeprecession
AT vandsburgermorielh gadoliniumfreecardiovascularmagneticresonancewith2pointcinebalancedsteadystatefreeprecession