Cargando…
Fatal Injury of the Small Intestine during Retropubic Sling Placement
We describe a case of injury of the small intestine in a patient who underwent placement of Align R retropubic urethral support system (BARD). Absence of characteristic symptoms of the bowel injury and peritonitis led to a rapid development of sepsis, multiple organ failure, and death. Although the...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4628685/ https://www.ncbi.nlm.nih.gov/pubmed/26557396 http://dx.doi.org/10.1155/2015/164545 |
_version_ | 1782398470696468480 |
---|---|
author | Kascak, P. Kopcan, B. |
author_facet | Kascak, P. Kopcan, B. |
author_sort | Kascak, P. |
collection | PubMed |
description | We describe a case of injury of the small intestine in a patient who underwent placement of Align R retropubic urethral support system (BARD). Absence of characteristic symptoms of the bowel injury and peritonitis led to a rapid development of sepsis, multiple organ failure, and death. Although the placement of midurethral sling is a minimally invasive surgery, good diagnostic skills, proper evaluation of indications, safe performance of the procedure, and thorough postsurgical monitoring are paramount for safe and effective outcome of the surgery. |
format | Online Article Text |
id | pubmed-4628685 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-46286852015-11-09 Fatal Injury of the Small Intestine during Retropubic Sling Placement Kascak, P. Kopcan, B. Case Rep Obstet Gynecol Case Report We describe a case of injury of the small intestine in a patient who underwent placement of Align R retropubic urethral support system (BARD). Absence of characteristic symptoms of the bowel injury and peritonitis led to a rapid development of sepsis, multiple organ failure, and death. Although the placement of midurethral sling is a minimally invasive surgery, good diagnostic skills, proper evaluation of indications, safe performance of the procedure, and thorough postsurgical monitoring are paramount for safe and effective outcome of the surgery. Hindawi Publishing Corporation 2015 2015-10-18 /pmc/articles/PMC4628685/ /pubmed/26557396 http://dx.doi.org/10.1155/2015/164545 Text en Copyright © 2015 P. Kascak and B. Kopcan. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Kascak, P. Kopcan, B. Fatal Injury of the Small Intestine during Retropubic Sling Placement |
title | Fatal Injury of the Small Intestine during Retropubic Sling Placement |
title_full | Fatal Injury of the Small Intestine during Retropubic Sling Placement |
title_fullStr | Fatal Injury of the Small Intestine during Retropubic Sling Placement |
title_full_unstemmed | Fatal Injury of the Small Intestine during Retropubic Sling Placement |
title_short | Fatal Injury of the Small Intestine during Retropubic Sling Placement |
title_sort | fatal injury of the small intestine during retropubic sling placement |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4628685/ https://www.ncbi.nlm.nih.gov/pubmed/26557396 http://dx.doi.org/10.1155/2015/164545 |
work_keys_str_mv | AT kascakp fatalinjuryofthesmallintestineduringretropubicslingplacement AT kopcanb fatalinjuryofthesmallintestineduringretropubicslingplacement |