Cargando…
Simultaneous determination of 3-chlorotyrosine and 3-nitrotyrosine in human plasma by direct analysis in real time–tandem mass spectrometry
A novel method for the simultaneous determination of 3-nitrotyrosine (NT) and 3-chlorotyrosine (CT) in human plasma has been developed based on direct analysis in real time–tandem mass spectrometry (DART–MS/MS). Analysis was performed in the positive ionization mode using multiple reaction monitorin...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4629445/ https://www.ncbi.nlm.nih.gov/pubmed/26579479 http://dx.doi.org/10.1016/j.apsb.2015.07.004 |
_version_ | 1782398578390466560 |
---|---|
author | Song, Yuqiao Liao, Jie Zha, Cheng Wang, Bin Liu, Charles C. |
author_facet | Song, Yuqiao Liao, Jie Zha, Cheng Wang, Bin Liu, Charles C. |
author_sort | Song, Yuqiao |
collection | PubMed |
description | A novel method for the simultaneous determination of 3-nitrotyrosine (NT) and 3-chlorotyrosine (CT) in human plasma has been developed based on direct analysis in real time–tandem mass spectrometry (DART–MS/MS). Analysis was performed in the positive ionization mode using multiple reaction monitoring (MRM) of the ion transitions at m/z 216.2/170.1 for CT, m/z 227.2/181.1 for NT and m/z 230.2/184.2 for the internal standard, d(3)-NT. The assay was linear in the ranges 0.5–100 μg/mL for CT and 4–100 μg/mL for NT with corresponding limits of detection of 0.2 and 2 μg/mL. Intra- and inter-day precisions and accuracies were respectively <15% and ±15%. Matrix effects were also evaluated. The method is potentially useful for high throughput analysis although sensitivity needs to be improved before it can be applied in clinical research. |
format | Online Article Text |
id | pubmed-4629445 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-46294452015-11-17 Simultaneous determination of 3-chlorotyrosine and 3-nitrotyrosine in human plasma by direct analysis in real time–tandem mass spectrometry Song, Yuqiao Liao, Jie Zha, Cheng Wang, Bin Liu, Charles C. Acta Pharm Sin B Short Communication A novel method for the simultaneous determination of 3-nitrotyrosine (NT) and 3-chlorotyrosine (CT) in human plasma has been developed based on direct analysis in real time–tandem mass spectrometry (DART–MS/MS). Analysis was performed in the positive ionization mode using multiple reaction monitoring (MRM) of the ion transitions at m/z 216.2/170.1 for CT, m/z 227.2/181.1 for NT and m/z 230.2/184.2 for the internal standard, d(3)-NT. The assay was linear in the ranges 0.5–100 μg/mL for CT and 4–100 μg/mL for NT with corresponding limits of detection of 0.2 and 2 μg/mL. Intra- and inter-day precisions and accuracies were respectively <15% and ±15%. Matrix effects were also evaluated. The method is potentially useful for high throughput analysis although sensitivity needs to be improved before it can be applied in clinical research. Elsevier 2015-09 2015-08-29 /pmc/articles/PMC4629445/ /pubmed/26579479 http://dx.doi.org/10.1016/j.apsb.2015.07.004 Text en © 2015 Chinese Pharmaceutical Association and Institute of Materia Medica, Chinese Academy of Medical Sciences. Production and hosting by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Short Communication Song, Yuqiao Liao, Jie Zha, Cheng Wang, Bin Liu, Charles C. Simultaneous determination of 3-chlorotyrosine and 3-nitrotyrosine in human plasma by direct analysis in real time–tandem mass spectrometry |
title | Simultaneous determination of 3-chlorotyrosine and 3-nitrotyrosine in human plasma by direct analysis in real time–tandem mass spectrometry |
title_full | Simultaneous determination of 3-chlorotyrosine and 3-nitrotyrosine in human plasma by direct analysis in real time–tandem mass spectrometry |
title_fullStr | Simultaneous determination of 3-chlorotyrosine and 3-nitrotyrosine in human plasma by direct analysis in real time–tandem mass spectrometry |
title_full_unstemmed | Simultaneous determination of 3-chlorotyrosine and 3-nitrotyrosine in human plasma by direct analysis in real time–tandem mass spectrometry |
title_short | Simultaneous determination of 3-chlorotyrosine and 3-nitrotyrosine in human plasma by direct analysis in real time–tandem mass spectrometry |
title_sort | simultaneous determination of 3-chlorotyrosine and 3-nitrotyrosine in human plasma by direct analysis in real time–tandem mass spectrometry |
topic | Short Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4629445/ https://www.ncbi.nlm.nih.gov/pubmed/26579479 http://dx.doi.org/10.1016/j.apsb.2015.07.004 |
work_keys_str_mv | AT songyuqiao simultaneousdeterminationof3chlorotyrosineand3nitrotyrosineinhumanplasmabydirectanalysisinrealtimetandemmassspectrometry AT liaojie simultaneousdeterminationof3chlorotyrosineand3nitrotyrosineinhumanplasmabydirectanalysisinrealtimetandemmassspectrometry AT zhacheng simultaneousdeterminationof3chlorotyrosineand3nitrotyrosineinhumanplasmabydirectanalysisinrealtimetandemmassspectrometry AT wangbin simultaneousdeterminationof3chlorotyrosineand3nitrotyrosineinhumanplasmabydirectanalysisinrealtimetandemmassspectrometry AT liucharlesc simultaneousdeterminationof3chlorotyrosineand3nitrotyrosineinhumanplasmabydirectanalysisinrealtimetandemmassspectrometry |