Modified Open-Door Laminoplasty Using a Ceramic Spacer and Suture Fixation for Cervical Myelopathy
PURPOSE: To introduce a new simple technique using suture anchors and ceramic spacers to stabilize the elevated laminae in open-door cervical laminoplasty. Although ceramic spacers were placed in the opened laminae and fixed with nylon threads in this series, it was occasionally difficult to fix the...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Yonsei University College of Medicine
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4630056/ https://www.ncbi.nlm.nih.gov/pubmed/26446650 http://dx.doi.org/10.3349/ymj.2015.56.6.1651 |
_version_ | 1782398658099019776 |
---|---|
author | Ozawa, Tomoyuki Toyone, Tomoaki Shiboi, Ryutaro Inada, Kunimasa Oikawa, Yasuhiro Takahashi, Kazuhisa Ohtori, Seiji Inoue, Gen Miyagi, Masayuki Ishikawa, Tetsuhiro Shirahata, Toshiyuki Kudo, Yoshifumi Inagaki, Katsunori |
author_facet | Ozawa, Tomoyuki Toyone, Tomoaki Shiboi, Ryutaro Inada, Kunimasa Oikawa, Yasuhiro Takahashi, Kazuhisa Ohtori, Seiji Inoue, Gen Miyagi, Masayuki Ishikawa, Tetsuhiro Shirahata, Toshiyuki Kudo, Yoshifumi Inagaki, Katsunori |
author_sort | Ozawa, Tomoyuki |
collection | PubMed |
description | PURPOSE: To introduce a new simple technique using suture anchors and ceramic spacers to stabilize the elevated laminae in open-door cervical laminoplasty. Although ceramic spacers were placed in the opened laminae and fixed with nylon threads in this series, it was occasionally difficult to fix the nylon threads to the lateral mass. MATERIALS AND METHODS: Study 1: A preliminary study was conducted using a suture anchor system. Sixteen consecutive patients who underwent surgery for cervical myelopathy were prospectively examined. Study 2: The second study was performed prospectively to evaluate the feasibility of this new technique based on the result of the preliminary study. Clinical outcomes were examined in 45 consecutive patients [cervical spondylotic myelopathy (CSM)] and 43 consecutive patients (OPLL). The Japanese Orthopedic Association scoring system (JOA score), axial neck pain, and radiological findings were analyzed. RESULTS: 1) In one case, re-operation was necessary due to dislodgement of the ceramic spacer following rupture of the thread. 2) In all patients, postoperative CT scans showed that the anchors were securely inserted into the bone. In the CSM group, the average JOA score improved from 9.5 points preoperatively to 13.3 at follow-up (recovery 51%). In the OPLL group, the average JOA score improved from 10.1 (5-14) points preoperatively to 14.4 (11-16) at follow-up (recovery 62%). There were no serious complications. CONCLUSION: The use of the suture anchor system made it unnecessary to create a hole in the lateral mass and enabled reliable and faster fixation of the HA spacers in open-door laminoplasty. |
format | Online Article Text |
id | pubmed-4630056 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Yonsei University College of Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-46300562015-11-04 Modified Open-Door Laminoplasty Using a Ceramic Spacer and Suture Fixation for Cervical Myelopathy Ozawa, Tomoyuki Toyone, Tomoaki Shiboi, Ryutaro Inada, Kunimasa Oikawa, Yasuhiro Takahashi, Kazuhisa Ohtori, Seiji Inoue, Gen Miyagi, Masayuki Ishikawa, Tetsuhiro Shirahata, Toshiyuki Kudo, Yoshifumi Inagaki, Katsunori Yonsei Med J Original Article PURPOSE: To introduce a new simple technique using suture anchors and ceramic spacers to stabilize the elevated laminae in open-door cervical laminoplasty. Although ceramic spacers were placed in the opened laminae and fixed with nylon threads in this series, it was occasionally difficult to fix the nylon threads to the lateral mass. MATERIALS AND METHODS: Study 1: A preliminary study was conducted using a suture anchor system. Sixteen consecutive patients who underwent surgery for cervical myelopathy were prospectively examined. Study 2: The second study was performed prospectively to evaluate the feasibility of this new technique based on the result of the preliminary study. Clinical outcomes were examined in 45 consecutive patients [cervical spondylotic myelopathy (CSM)] and 43 consecutive patients (OPLL). The Japanese Orthopedic Association scoring system (JOA score), axial neck pain, and radiological findings were analyzed. RESULTS: 1) In one case, re-operation was necessary due to dislodgement of the ceramic spacer following rupture of the thread. 2) In all patients, postoperative CT scans showed that the anchors were securely inserted into the bone. In the CSM group, the average JOA score improved from 9.5 points preoperatively to 13.3 at follow-up (recovery 51%). In the OPLL group, the average JOA score improved from 10.1 (5-14) points preoperatively to 14.4 (11-16) at follow-up (recovery 62%). There were no serious complications. CONCLUSION: The use of the suture anchor system made it unnecessary to create a hole in the lateral mass and enabled reliable and faster fixation of the HA spacers in open-door laminoplasty. Yonsei University College of Medicine 2015-11-01 2015-09-25 /pmc/articles/PMC4630056/ /pubmed/26446650 http://dx.doi.org/10.3349/ymj.2015.56.6.1651 Text en © Copyright: Yonsei University College of Medicine 2015 http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Ozawa, Tomoyuki Toyone, Tomoaki Shiboi, Ryutaro Inada, Kunimasa Oikawa, Yasuhiro Takahashi, Kazuhisa Ohtori, Seiji Inoue, Gen Miyagi, Masayuki Ishikawa, Tetsuhiro Shirahata, Toshiyuki Kudo, Yoshifumi Inagaki, Katsunori Modified Open-Door Laminoplasty Using a Ceramic Spacer and Suture Fixation for Cervical Myelopathy |
title | Modified Open-Door Laminoplasty Using a Ceramic Spacer and Suture Fixation for Cervical Myelopathy |
title_full | Modified Open-Door Laminoplasty Using a Ceramic Spacer and Suture Fixation for Cervical Myelopathy |
title_fullStr | Modified Open-Door Laminoplasty Using a Ceramic Spacer and Suture Fixation for Cervical Myelopathy |
title_full_unstemmed | Modified Open-Door Laminoplasty Using a Ceramic Spacer and Suture Fixation for Cervical Myelopathy |
title_short | Modified Open-Door Laminoplasty Using a Ceramic Spacer and Suture Fixation for Cervical Myelopathy |
title_sort | modified open-door laminoplasty using a ceramic spacer and suture fixation for cervical myelopathy |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4630056/ https://www.ncbi.nlm.nih.gov/pubmed/26446650 http://dx.doi.org/10.3349/ymj.2015.56.6.1651 |
work_keys_str_mv | AT ozawatomoyuki modifiedopendoorlaminoplastyusingaceramicspacerandsuturefixationforcervicalmyelopathy AT toyonetomoaki modifiedopendoorlaminoplastyusingaceramicspacerandsuturefixationforcervicalmyelopathy AT shiboiryutaro modifiedopendoorlaminoplastyusingaceramicspacerandsuturefixationforcervicalmyelopathy AT inadakunimasa modifiedopendoorlaminoplastyusingaceramicspacerandsuturefixationforcervicalmyelopathy AT oikawayasuhiro modifiedopendoorlaminoplastyusingaceramicspacerandsuturefixationforcervicalmyelopathy AT takahashikazuhisa modifiedopendoorlaminoplastyusingaceramicspacerandsuturefixationforcervicalmyelopathy AT ohtoriseiji modifiedopendoorlaminoplastyusingaceramicspacerandsuturefixationforcervicalmyelopathy AT inouegen modifiedopendoorlaminoplastyusingaceramicspacerandsuturefixationforcervicalmyelopathy AT miyagimasayuki modifiedopendoorlaminoplastyusingaceramicspacerandsuturefixationforcervicalmyelopathy AT ishikawatetsuhiro modifiedopendoorlaminoplastyusingaceramicspacerandsuturefixationforcervicalmyelopathy AT shirahatatoshiyuki modifiedopendoorlaminoplastyusingaceramicspacerandsuturefixationforcervicalmyelopathy AT kudoyoshifumi modifiedopendoorlaminoplastyusingaceramicspacerandsuturefixationforcervicalmyelopathy AT inagakikatsunori modifiedopendoorlaminoplastyusingaceramicspacerandsuturefixationforcervicalmyelopathy |