Cargando…
Task-Dependent Intermuscular Motor Unit Synchronization between Medial and Lateral Vastii Muscles during Dynamic and Isometric Squats
PURPOSE: Motor unit activity is coordinated between many synergistic muscle pairs but the functional role of this coordination for the motor output is unclear. The purpose of this study was to investigate the short-term modality of coordinated motor unit activity–the synchronized discharge of indivi...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4631473/ https://www.ncbi.nlm.nih.gov/pubmed/26529604 http://dx.doi.org/10.1371/journal.pone.0142048 |
_version_ | 1782398870158835712 |
---|---|
author | Mohr, Maurice Nann, Marius von Tscharner, Vinzenz Eskofier, Bjoern Nigg, Benno Maurus |
author_facet | Mohr, Maurice Nann, Marius von Tscharner, Vinzenz Eskofier, Bjoern Nigg, Benno Maurus |
author_sort | Mohr, Maurice |
collection | PubMed |
description | PURPOSE: Motor unit activity is coordinated between many synergistic muscle pairs but the functional role of this coordination for the motor output is unclear. The purpose of this study was to investigate the short-term modality of coordinated motor unit activity–the synchronized discharge of individual motor units across muscles within time intervals of 5ms–for the Vastus Medialis (VM) and Lateralis (VL). Furthermore, we studied the task-dependency of intermuscular motor unit synchronization between VM and VL during static and dynamic squatting tasks to provide insight into its functional role. METHODS: Sixteen healthy male and female participants completed four tasks: Bipedal squats, single-leg squats, an isometric squat, and single-leg balance. Monopolar surface electromyography (EMG) was used to record motor unit activity of VM and VL. For each task, intermuscular motor unit synchronization was determined using a coherence analysis between the raw EMG signals of VM and VL and compared to a reference coherence calculated from two desynchronized EMG signals. The time shift between VM and VL EMG signals was estimated according to the slope of the coherence phase angle spectrum. RESULTS: For all tasks, except for singe-leg balance, coherence between 15–80Hz significantly exceeded the reference. The corresponding time shift between VM and VL was estimated as 4ms. Coherence between 30–60Hz was highest for the bipedal squat, followed by the single-leg squat and the isometric squat. CONCLUSION: There is substantial short-term motor unit synchronization between VM and VL. Intermuscular motor unit synchronization is enhanced for contractions during dynamic activities, possibly to facilitate a more accurate control of the joint torque, and reduced during single-leg tasks that require balance control and thus, a more independent muscle function. It is proposed that the central nervous system scales the degree of intermuscular motor unit synchronization according to the requirements of the movement task at hand. |
format | Online Article Text |
id | pubmed-4631473 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-46314732015-11-13 Task-Dependent Intermuscular Motor Unit Synchronization between Medial and Lateral Vastii Muscles during Dynamic and Isometric Squats Mohr, Maurice Nann, Marius von Tscharner, Vinzenz Eskofier, Bjoern Nigg, Benno Maurus PLoS One Research Article PURPOSE: Motor unit activity is coordinated between many synergistic muscle pairs but the functional role of this coordination for the motor output is unclear. The purpose of this study was to investigate the short-term modality of coordinated motor unit activity–the synchronized discharge of individual motor units across muscles within time intervals of 5ms–for the Vastus Medialis (VM) and Lateralis (VL). Furthermore, we studied the task-dependency of intermuscular motor unit synchronization between VM and VL during static and dynamic squatting tasks to provide insight into its functional role. METHODS: Sixteen healthy male and female participants completed four tasks: Bipedal squats, single-leg squats, an isometric squat, and single-leg balance. Monopolar surface electromyography (EMG) was used to record motor unit activity of VM and VL. For each task, intermuscular motor unit synchronization was determined using a coherence analysis between the raw EMG signals of VM and VL and compared to a reference coherence calculated from two desynchronized EMG signals. The time shift between VM and VL EMG signals was estimated according to the slope of the coherence phase angle spectrum. RESULTS: For all tasks, except for singe-leg balance, coherence between 15–80Hz significantly exceeded the reference. The corresponding time shift between VM and VL was estimated as 4ms. Coherence between 30–60Hz was highest for the bipedal squat, followed by the single-leg squat and the isometric squat. CONCLUSION: There is substantial short-term motor unit synchronization between VM and VL. Intermuscular motor unit synchronization is enhanced for contractions during dynamic activities, possibly to facilitate a more accurate control of the joint torque, and reduced during single-leg tasks that require balance control and thus, a more independent muscle function. It is proposed that the central nervous system scales the degree of intermuscular motor unit synchronization according to the requirements of the movement task at hand. Public Library of Science 2015-11-03 /pmc/articles/PMC4631473/ /pubmed/26529604 http://dx.doi.org/10.1371/journal.pone.0142048 Text en © 2015 Mohr et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Mohr, Maurice Nann, Marius von Tscharner, Vinzenz Eskofier, Bjoern Nigg, Benno Maurus Task-Dependent Intermuscular Motor Unit Synchronization between Medial and Lateral Vastii Muscles during Dynamic and Isometric Squats |
title | Task-Dependent Intermuscular Motor Unit Synchronization between Medial and Lateral Vastii Muscles during Dynamic and Isometric Squats |
title_full | Task-Dependent Intermuscular Motor Unit Synchronization between Medial and Lateral Vastii Muscles during Dynamic and Isometric Squats |
title_fullStr | Task-Dependent Intermuscular Motor Unit Synchronization between Medial and Lateral Vastii Muscles during Dynamic and Isometric Squats |
title_full_unstemmed | Task-Dependent Intermuscular Motor Unit Synchronization between Medial and Lateral Vastii Muscles during Dynamic and Isometric Squats |
title_short | Task-Dependent Intermuscular Motor Unit Synchronization between Medial and Lateral Vastii Muscles during Dynamic and Isometric Squats |
title_sort | task-dependent intermuscular motor unit synchronization between medial and lateral vastii muscles during dynamic and isometric squats |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4631473/ https://www.ncbi.nlm.nih.gov/pubmed/26529604 http://dx.doi.org/10.1371/journal.pone.0142048 |
work_keys_str_mv | AT mohrmaurice taskdependentintermuscularmotorunitsynchronizationbetweenmedialandlateralvastiimusclesduringdynamicandisometricsquats AT nannmarius taskdependentintermuscularmotorunitsynchronizationbetweenmedialandlateralvastiimusclesduringdynamicandisometricsquats AT vontscharnervinzenz taskdependentintermuscularmotorunitsynchronizationbetweenmedialandlateralvastiimusclesduringdynamicandisometricsquats AT eskofierbjoern taskdependentintermuscularmotorunitsynchronizationbetweenmedialandlateralvastiimusclesduringdynamicandisometricsquats AT niggbennomaurus taskdependentintermuscularmotorunitsynchronizationbetweenmedialandlateralvastiimusclesduringdynamicandisometricsquats |