Cargando…
Artificial aortic valve dysfunction due to pannus and thrombus – different methods of cardiac surgical management
INTRODUCTION: Approximately 60 000 prosthetic valves are implanted annually in the USA. The risk of prosthesis dysfunction ranges from 0.1% to 4% per year. Prosthesis valve dysfunction is usually caused by a thrombus obstructing the prosthetic discs. However, 10% of prosthetic valves are dysfunction...
Autores principales: | Ostrowski, Stanisław, Marcinkiewicz, Anna, Kośmider, Anna, Walczak, Andrzej, Zwoliński, Radosław, Jaszewski, Ryszard |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Termedia Publishing House
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4631909/ https://www.ncbi.nlm.nih.gov/pubmed/26702274 http://dx.doi.org/10.5114/kitp.2015.54453 |
Ejemplares similares
-
Comparison of the clinical application of reactive oxygen species and inflammatory markers in patients with endocarditis
por: Ostrowski, Stanisław, et al.
Publicado: (2012) -
Urgent splenectomy in the course of prosthetic valve endocarditis
por: Marcinkiewicz, Anna, et al.
Publicado: (2014) -
Sarcomas of the heart as a difficult interdisciplinary problem
por: Ostrowski, Stanisław, et al.
Publicado: (2014) -
Cardiac tamponade and para-aortic hematoma post elective surgical myocardial revascularization on a beating heart – a possible complication of the Lima-stitch and sequential venous anastomosis
por: Marcinkiewicz, Anna, et al.
Publicado: (2014) -
Does the additional usage of a local hemostatic patch reduce bleeding after aortic reimplantation?
por: Ostrowski, Stanisław, et al.
Publicado: (2018)