Surgical removal of entrapped guidewire fragment following direct circumflex artery angioplasty and stenting

We present a case of a 64-year-old man with coronary artery disease, who underwent a percutaneous coronary intervention of the circumflex artery. As the guidewire was being withdrawn from the target vessel, it became entrapped by the structure of the previously implanted stent. Attempts to retrieve...

Descripción completa

Detalles Bibliográficos
Autores principales: Domaradzki, Wojciech, Sanetra, Krzysztof, Skwarna, Bartosz, Król, Marek, Kuczera, Małgorzata, Cisowski, Marek
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4631917/
https://www.ncbi.nlm.nih.gov/pubmed/26702281
http://dx.doi.org/10.5114/kitp.2015.54461
Descripción
Sumario:We present a case of a 64-year-old man with coronary artery disease, who underwent a percutaneous coronary intervention of the circumflex artery. As the guidewire was being withdrawn from the target vessel, it became entrapped by the structure of the previously implanted stent. Attempts to retrieve the foreign body were unsuccessful. Changes in electrocardiogram were observed during the procedure, and the level of cardiac biomarkers increased within the next 24-hours. The patient was admitted to the Cardiac Surgery Department. Remnants of the foreign body were removed under visual control using extracorporeal circulation, and coronary artery bypass grafting was performed. Treatment options and outcomes are discussed.