Cargando…

The effect of preheated versus room-temperature skin disinfection on bacterial colonization during pacemaker device implantation: a randomized controlled non-inferiority trial

BACKGROUND: In clinical practice, patients who are awake often comment that cold surgical skin disinfectant is unpleasant. This is not only a problem of patients’ experience; heat loss during the disinfection process is a problem that can result in hypothermia. Evidence for the efficacy of preheated...

Descripción completa

Detalles Bibliográficos
Autores principales: Wistrand, Camilla, Söderquist, Bo, Magnusson, Anders, Nilsson, Ulrica
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4632481/
https://www.ncbi.nlm.nih.gov/pubmed/26539295
http://dx.doi.org/10.1186/s13756-015-0084-1
_version_ 1782399040697139200
author Wistrand, Camilla
Söderquist, Bo
Magnusson, Anders
Nilsson, Ulrica
author_facet Wistrand, Camilla
Söderquist, Bo
Magnusson, Anders
Nilsson, Ulrica
author_sort Wistrand, Camilla
collection PubMed
description BACKGROUND: In clinical practice, patients who are awake often comment that cold surgical skin disinfectant is unpleasant. This is not only a problem of patients’ experience; heat loss during the disinfection process is a problem that can result in hypothermia. Evidence for the efficacy of preheated disinfection is scarce. We tested whether preheated skin disinfectant was non-inferior to room-temperature skin disinfectant on reducing bacterial colonization during pacemaker implantation. METHODS: This randomized, controlled, non-inferiority trial included 220 patients allocated to skin disinfection with preheated (36 °C) or room-temperature (20 °C) chlorhexidine solution in 70 % ethanol. Cultures were obtained by swabbing at 4 time-points; 1) before skin disinfection (skin surface), 2) after skin disinfection (skin surface), 3) after the incision (subcutaneously in the wound), and 4) before suturing (subcutaneously in the wound). RESULTS: The absolute difference in growth between patients treated with preheated versus room-temperature skin disinfectant was zero (90 % CI −0.101 to 0.101; preheated: 30 of 105 [28.6 %] vs. room-temperature: 32 of 112 [28.6 %]). The pre-specified margin for statistical non-inferiority in the protocol was set at 10 % for the preheated disinfectant. There were no significant differences between groups regarding SSIs three month postoperatively, which occurred in 0.9 % (1 of 108) treated with preheated and 1.8 % (2 of 112) treated with room-temperature skin disinfectant. CONCLUSION: Preheated skin disinfection is non-inferior to room-temperature disinfection in bacterial reduction. We therefore suggest that preheated skin disinfection become routine in clean surgery. TRIAL REGISTRATION: The study is registered at ClinicalTrials.gov (NCTO2260479).
format Online
Article
Text
id pubmed-4632481
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-46324812015-11-05 The effect of preheated versus room-temperature skin disinfection on bacterial colonization during pacemaker device implantation: a randomized controlled non-inferiority trial Wistrand, Camilla Söderquist, Bo Magnusson, Anders Nilsson, Ulrica Antimicrob Resist Infect Control Research BACKGROUND: In clinical practice, patients who are awake often comment that cold surgical skin disinfectant is unpleasant. This is not only a problem of patients’ experience; heat loss during the disinfection process is a problem that can result in hypothermia. Evidence for the efficacy of preheated disinfection is scarce. We tested whether preheated skin disinfectant was non-inferior to room-temperature skin disinfectant on reducing bacterial colonization during pacemaker implantation. METHODS: This randomized, controlled, non-inferiority trial included 220 patients allocated to skin disinfection with preheated (36 °C) or room-temperature (20 °C) chlorhexidine solution in 70 % ethanol. Cultures were obtained by swabbing at 4 time-points; 1) before skin disinfection (skin surface), 2) after skin disinfection (skin surface), 3) after the incision (subcutaneously in the wound), and 4) before suturing (subcutaneously in the wound). RESULTS: The absolute difference in growth between patients treated with preheated versus room-temperature skin disinfectant was zero (90 % CI −0.101 to 0.101; preheated: 30 of 105 [28.6 %] vs. room-temperature: 32 of 112 [28.6 %]). The pre-specified margin for statistical non-inferiority in the protocol was set at 10 % for the preheated disinfectant. There were no significant differences between groups regarding SSIs three month postoperatively, which occurred in 0.9 % (1 of 108) treated with preheated and 1.8 % (2 of 112) treated with room-temperature skin disinfectant. CONCLUSION: Preheated skin disinfection is non-inferior to room-temperature disinfection in bacterial reduction. We therefore suggest that preheated skin disinfection become routine in clean surgery. TRIAL REGISTRATION: The study is registered at ClinicalTrials.gov (NCTO2260479). BioMed Central 2015-11-03 /pmc/articles/PMC4632481/ /pubmed/26539295 http://dx.doi.org/10.1186/s13756-015-0084-1 Text en © Wistrand et al. 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Wistrand, Camilla
Söderquist, Bo
Magnusson, Anders
Nilsson, Ulrica
The effect of preheated versus room-temperature skin disinfection on bacterial colonization during pacemaker device implantation: a randomized controlled non-inferiority trial
title The effect of preheated versus room-temperature skin disinfection on bacterial colonization during pacemaker device implantation: a randomized controlled non-inferiority trial
title_full The effect of preheated versus room-temperature skin disinfection on bacterial colonization during pacemaker device implantation: a randomized controlled non-inferiority trial
title_fullStr The effect of preheated versus room-temperature skin disinfection on bacterial colonization during pacemaker device implantation: a randomized controlled non-inferiority trial
title_full_unstemmed The effect of preheated versus room-temperature skin disinfection on bacterial colonization during pacemaker device implantation: a randomized controlled non-inferiority trial
title_short The effect of preheated versus room-temperature skin disinfection on bacterial colonization during pacemaker device implantation: a randomized controlled non-inferiority trial
title_sort effect of preheated versus room-temperature skin disinfection on bacterial colonization during pacemaker device implantation: a randomized controlled non-inferiority trial
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4632481/
https://www.ncbi.nlm.nih.gov/pubmed/26539295
http://dx.doi.org/10.1186/s13756-015-0084-1
work_keys_str_mv AT wistrandcamilla theeffectofpreheatedversusroomtemperatureskindisinfectiononbacterialcolonizationduringpacemakerdeviceimplantationarandomizedcontrollednoninferioritytrial
AT soderquistbo theeffectofpreheatedversusroomtemperatureskindisinfectiononbacterialcolonizationduringpacemakerdeviceimplantationarandomizedcontrollednoninferioritytrial
AT magnussonanders theeffectofpreheatedversusroomtemperatureskindisinfectiononbacterialcolonizationduringpacemakerdeviceimplantationarandomizedcontrollednoninferioritytrial
AT nilssonulrica theeffectofpreheatedversusroomtemperatureskindisinfectiononbacterialcolonizationduringpacemakerdeviceimplantationarandomizedcontrollednoninferioritytrial
AT wistrandcamilla effectofpreheatedversusroomtemperatureskindisinfectiononbacterialcolonizationduringpacemakerdeviceimplantationarandomizedcontrollednoninferioritytrial
AT soderquistbo effectofpreheatedversusroomtemperatureskindisinfectiononbacterialcolonizationduringpacemakerdeviceimplantationarandomizedcontrollednoninferioritytrial
AT magnussonanders effectofpreheatedversusroomtemperatureskindisinfectiononbacterialcolonizationduringpacemakerdeviceimplantationarandomizedcontrollednoninferioritytrial
AT nilssonulrica effectofpreheatedversusroomtemperatureskindisinfectiononbacterialcolonizationduringpacemakerdeviceimplantationarandomizedcontrollednoninferioritytrial