Cargando…
Comparing the Effect of Different Voxel Resolutions for Assessment of Vertical Root Fracture of Permanent Teeth
BACKGROUND: The teeth with undiagnosed vertical root fractures (VRFs) are likely to receive endodontic treatment or retreatment, leading to frustration and inappropriate endodontic therapies. Moreover, many cases of VRFs cannot be diagnosed definitively until the extraction of tooth. OBJECTIVES: Thi...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Kowsar
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4632561/ https://www.ncbi.nlm.nih.gov/pubmed/26557279 http://dx.doi.org/10.5812/iranjradiol.18290 |
_version_ | 1782399056664854528 |
---|---|
author | Uzun, Ismail Gunduz, Kaan Celenk, Peruze Avsever, Hakan Orhan, Kaan Canitezer, Gozde Ozmen, Bilal Cicek, Ersan Egrioglu, Erol |
author_facet | Uzun, Ismail Gunduz, Kaan Celenk, Peruze Avsever, Hakan Orhan, Kaan Canitezer, Gozde Ozmen, Bilal Cicek, Ersan Egrioglu, Erol |
author_sort | Uzun, Ismail |
collection | PubMed |
description | BACKGROUND: The teeth with undiagnosed vertical root fractures (VRFs) are likely to receive endodontic treatment or retreatment, leading to frustration and inappropriate endodontic therapies. Moreover, many cases of VRFs cannot be diagnosed definitively until the extraction of tooth. OBJECTIVES: This study aimed to assess the use of different voxel resolutions of two different cone beam computerized tomography (CBCT) units in the detection VRFs in vitro. MATERIALS AND METHODS: The study material comprised 74 extracted human mandibular single rooted premolar teeth without root fractures that had not undergone any root-canal treatment. Images were obtained by two different CBCT units. Four image sets were obtained as follows: 1) 3D Accuitomo 170, 4 × 4 cm field of view (FOV) (0.080 mm(3)); 2) 3D Accuitomo 170. 6 × 6 cm FOV (0.125 mm(3)); 3) NewTom 3G, 6˝ (0.16 mm(3)) and 4) NewTom 3G, 9˝ FOV (0.25 mm(3)). Kappa coefficients were calculated to assess both intra- and inter-observer agreements for each image set. RESULTS: No significant differences were found among observers or voxel sizes, with high average Z (Az) results being reported for all groups. Both intra- and inter-observer agreement values were relatively better for 3D Accuitomo 170 images than the images from NewTom 3G. The highest Az and kappa values were obtained with 3D Accuitomo 170, 4 × 4 cm FOV (0.080 mm(3)) images. CONCLUSION: No significant differences were found among observers or voxel sizes, with high Az results reported for all groups. |
format | Online Article Text |
id | pubmed-4632561 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Kowsar |
record_format | MEDLINE/PubMed |
spelling | pubmed-46325612015-11-09 Comparing the Effect of Different Voxel Resolutions for Assessment of Vertical Root Fracture of Permanent Teeth Uzun, Ismail Gunduz, Kaan Celenk, Peruze Avsever, Hakan Orhan, Kaan Canitezer, Gozde Ozmen, Bilal Cicek, Ersan Egrioglu, Erol Iran J Radiol Head & Neck Imaging BACKGROUND: The teeth with undiagnosed vertical root fractures (VRFs) are likely to receive endodontic treatment or retreatment, leading to frustration and inappropriate endodontic therapies. Moreover, many cases of VRFs cannot be diagnosed definitively until the extraction of tooth. OBJECTIVES: This study aimed to assess the use of different voxel resolutions of two different cone beam computerized tomography (CBCT) units in the detection VRFs in vitro. MATERIALS AND METHODS: The study material comprised 74 extracted human mandibular single rooted premolar teeth without root fractures that had not undergone any root-canal treatment. Images were obtained by two different CBCT units. Four image sets were obtained as follows: 1) 3D Accuitomo 170, 4 × 4 cm field of view (FOV) (0.080 mm(3)); 2) 3D Accuitomo 170. 6 × 6 cm FOV (0.125 mm(3)); 3) NewTom 3G, 6˝ (0.16 mm(3)) and 4) NewTom 3G, 9˝ FOV (0.25 mm(3)). Kappa coefficients were calculated to assess both intra- and inter-observer agreements for each image set. RESULTS: No significant differences were found among observers or voxel sizes, with high average Z (Az) results being reported for all groups. Both intra- and inter-observer agreement values were relatively better for 3D Accuitomo 170 images than the images from NewTom 3G. The highest Az and kappa values were obtained with 3D Accuitomo 170, 4 × 4 cm FOV (0.080 mm(3)) images. CONCLUSION: No significant differences were found among observers or voxel sizes, with high Az results reported for all groups. Kowsar 2015-07-22 /pmc/articles/PMC4632561/ /pubmed/26557279 http://dx.doi.org/10.5812/iranjradiol.18290 Text en Copyright © 2015, Tehran University of Medical Sciences and Iranian Society of Radiology. http://creativecommons.org/licenses/by-nc/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/) which permits copy and redistribute the material just in noncommercial usages, provided the original work is properly cited. |
spellingShingle | Head & Neck Imaging Uzun, Ismail Gunduz, Kaan Celenk, Peruze Avsever, Hakan Orhan, Kaan Canitezer, Gozde Ozmen, Bilal Cicek, Ersan Egrioglu, Erol Comparing the Effect of Different Voxel Resolutions for Assessment of Vertical Root Fracture of Permanent Teeth |
title | Comparing the Effect of Different Voxel Resolutions for Assessment of Vertical Root Fracture of Permanent Teeth |
title_full | Comparing the Effect of Different Voxel Resolutions for Assessment of Vertical Root Fracture of Permanent Teeth |
title_fullStr | Comparing the Effect of Different Voxel Resolutions for Assessment of Vertical Root Fracture of Permanent Teeth |
title_full_unstemmed | Comparing the Effect of Different Voxel Resolutions for Assessment of Vertical Root Fracture of Permanent Teeth |
title_short | Comparing the Effect of Different Voxel Resolutions for Assessment of Vertical Root Fracture of Permanent Teeth |
title_sort | comparing the effect of different voxel resolutions for assessment of vertical root fracture of permanent teeth |
topic | Head & Neck Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4632561/ https://www.ncbi.nlm.nih.gov/pubmed/26557279 http://dx.doi.org/10.5812/iranjradiol.18290 |
work_keys_str_mv | AT uzunismail comparingtheeffectofdifferentvoxelresolutionsforassessmentofverticalrootfractureofpermanentteeth AT gunduzkaan comparingtheeffectofdifferentvoxelresolutionsforassessmentofverticalrootfractureofpermanentteeth AT celenkperuze comparingtheeffectofdifferentvoxelresolutionsforassessmentofverticalrootfractureofpermanentteeth AT avseverhakan comparingtheeffectofdifferentvoxelresolutionsforassessmentofverticalrootfractureofpermanentteeth AT orhankaan comparingtheeffectofdifferentvoxelresolutionsforassessmentofverticalrootfractureofpermanentteeth AT canitezergozde comparingtheeffectofdifferentvoxelresolutionsforassessmentofverticalrootfractureofpermanentteeth AT ozmenbilal comparingtheeffectofdifferentvoxelresolutionsforassessmentofverticalrootfractureofpermanentteeth AT cicekersan comparingtheeffectofdifferentvoxelresolutionsforassessmentofverticalrootfractureofpermanentteeth AT egriogluerol comparingtheeffectofdifferentvoxelresolutionsforassessmentofverticalrootfractureofpermanentteeth |