Cargando…

Comparing the Effect of Different Voxel Resolutions for Assessment of Vertical Root Fracture of Permanent Teeth

BACKGROUND: The teeth with undiagnosed vertical root fractures (VRFs) are likely to receive endodontic treatment or retreatment, leading to frustration and inappropriate endodontic therapies. Moreover, many cases of VRFs cannot be diagnosed definitively until the extraction of tooth. OBJECTIVES: Thi...

Descripción completa

Detalles Bibliográficos
Autores principales: Uzun, Ismail, Gunduz, Kaan, Celenk, Peruze, Avsever, Hakan, Orhan, Kaan, Canitezer, Gozde, Ozmen, Bilal, Cicek, Ersan, Egrioglu, Erol
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Kowsar 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4632561/
https://www.ncbi.nlm.nih.gov/pubmed/26557279
http://dx.doi.org/10.5812/iranjradiol.18290
_version_ 1782399056664854528
author Uzun, Ismail
Gunduz, Kaan
Celenk, Peruze
Avsever, Hakan
Orhan, Kaan
Canitezer, Gozde
Ozmen, Bilal
Cicek, Ersan
Egrioglu, Erol
author_facet Uzun, Ismail
Gunduz, Kaan
Celenk, Peruze
Avsever, Hakan
Orhan, Kaan
Canitezer, Gozde
Ozmen, Bilal
Cicek, Ersan
Egrioglu, Erol
author_sort Uzun, Ismail
collection PubMed
description BACKGROUND: The teeth with undiagnosed vertical root fractures (VRFs) are likely to receive endodontic treatment or retreatment, leading to frustration and inappropriate endodontic therapies. Moreover, many cases of VRFs cannot be diagnosed definitively until the extraction of tooth. OBJECTIVES: This study aimed to assess the use of different voxel resolutions of two different cone beam computerized tomography (CBCT) units in the detection VRFs in vitro. MATERIALS AND METHODS: The study material comprised 74 extracted human mandibular single rooted premolar teeth without root fractures that had not undergone any root-canal treatment. Images were obtained by two different CBCT units. Four image sets were obtained as follows: 1) 3D Accuitomo 170, 4 × 4 cm field of view (FOV) (0.080 mm(3)); 2) 3D Accuitomo 170. 6 × 6 cm FOV (0.125 mm(3)); 3) NewTom 3G, 6˝ (0.16 mm(3)) and 4) NewTom 3G, 9˝ FOV (0.25 mm(3)). Kappa coefficients were calculated to assess both intra- and inter-observer agreements for each image set. RESULTS: No significant differences were found among observers or voxel sizes, with high average Z (Az) results being reported for all groups. Both intra- and inter-observer agreement values were relatively better for 3D Accuitomo 170 images than the images from NewTom 3G. The highest Az and kappa values were obtained with 3D Accuitomo 170, 4 × 4 cm FOV (0.080 mm(3)) images. CONCLUSION: No significant differences were found among observers or voxel sizes, with high Az results reported for all groups.
format Online
Article
Text
id pubmed-4632561
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Kowsar
record_format MEDLINE/PubMed
spelling pubmed-46325612015-11-09 Comparing the Effect of Different Voxel Resolutions for Assessment of Vertical Root Fracture of Permanent Teeth Uzun, Ismail Gunduz, Kaan Celenk, Peruze Avsever, Hakan Orhan, Kaan Canitezer, Gozde Ozmen, Bilal Cicek, Ersan Egrioglu, Erol Iran J Radiol Head & Neck Imaging BACKGROUND: The teeth with undiagnosed vertical root fractures (VRFs) are likely to receive endodontic treatment or retreatment, leading to frustration and inappropriate endodontic therapies. Moreover, many cases of VRFs cannot be diagnosed definitively until the extraction of tooth. OBJECTIVES: This study aimed to assess the use of different voxel resolutions of two different cone beam computerized tomography (CBCT) units in the detection VRFs in vitro. MATERIALS AND METHODS: The study material comprised 74 extracted human mandibular single rooted premolar teeth without root fractures that had not undergone any root-canal treatment. Images were obtained by two different CBCT units. Four image sets were obtained as follows: 1) 3D Accuitomo 170, 4 × 4 cm field of view (FOV) (0.080 mm(3)); 2) 3D Accuitomo 170. 6 × 6 cm FOV (0.125 mm(3)); 3) NewTom 3G, 6˝ (0.16 mm(3)) and 4) NewTom 3G, 9˝ FOV (0.25 mm(3)). Kappa coefficients were calculated to assess both intra- and inter-observer agreements for each image set. RESULTS: No significant differences were found among observers or voxel sizes, with high average Z (Az) results being reported for all groups. Both intra- and inter-observer agreement values were relatively better for 3D Accuitomo 170 images than the images from NewTom 3G. The highest Az and kappa values were obtained with 3D Accuitomo 170, 4 × 4 cm FOV (0.080 mm(3)) images. CONCLUSION: No significant differences were found among observers or voxel sizes, with high Az results reported for all groups. Kowsar 2015-07-22 /pmc/articles/PMC4632561/ /pubmed/26557279 http://dx.doi.org/10.5812/iranjradiol.18290 Text en Copyright © 2015, Tehran University of Medical Sciences and Iranian Society of Radiology. http://creativecommons.org/licenses/by-nc/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/) which permits copy and redistribute the material just in noncommercial usages, provided the original work is properly cited.
spellingShingle Head & Neck Imaging
Uzun, Ismail
Gunduz, Kaan
Celenk, Peruze
Avsever, Hakan
Orhan, Kaan
Canitezer, Gozde
Ozmen, Bilal
Cicek, Ersan
Egrioglu, Erol
Comparing the Effect of Different Voxel Resolutions for Assessment of Vertical Root Fracture of Permanent Teeth
title Comparing the Effect of Different Voxel Resolutions for Assessment of Vertical Root Fracture of Permanent Teeth
title_full Comparing the Effect of Different Voxel Resolutions for Assessment of Vertical Root Fracture of Permanent Teeth
title_fullStr Comparing the Effect of Different Voxel Resolutions for Assessment of Vertical Root Fracture of Permanent Teeth
title_full_unstemmed Comparing the Effect of Different Voxel Resolutions for Assessment of Vertical Root Fracture of Permanent Teeth
title_short Comparing the Effect of Different Voxel Resolutions for Assessment of Vertical Root Fracture of Permanent Teeth
title_sort comparing the effect of different voxel resolutions for assessment of vertical root fracture of permanent teeth
topic Head & Neck Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4632561/
https://www.ncbi.nlm.nih.gov/pubmed/26557279
http://dx.doi.org/10.5812/iranjradiol.18290
work_keys_str_mv AT uzunismail comparingtheeffectofdifferentvoxelresolutionsforassessmentofverticalrootfractureofpermanentteeth
AT gunduzkaan comparingtheeffectofdifferentvoxelresolutionsforassessmentofverticalrootfractureofpermanentteeth
AT celenkperuze comparingtheeffectofdifferentvoxelresolutionsforassessmentofverticalrootfractureofpermanentteeth
AT avseverhakan comparingtheeffectofdifferentvoxelresolutionsforassessmentofverticalrootfractureofpermanentteeth
AT orhankaan comparingtheeffectofdifferentvoxelresolutionsforassessmentofverticalrootfractureofpermanentteeth
AT canitezergozde comparingtheeffectofdifferentvoxelresolutionsforassessmentofverticalrootfractureofpermanentteeth
AT ozmenbilal comparingtheeffectofdifferentvoxelresolutionsforassessmentofverticalrootfractureofpermanentteeth
AT cicekersan comparingtheeffectofdifferentvoxelresolutionsforassessmentofverticalrootfractureofpermanentteeth
AT egriogluerol comparingtheeffectofdifferentvoxelresolutionsforassessmentofverticalrootfractureofpermanentteeth