Supplemental S1 fixation for type C pelvic ring injuries: biomechanical study of a long iliosacral versus a transsacral screw

BACKGROUND: A single iliosacral screw placed into the S1 vertebral body has been shown to be clinically unreliable for certain type C pelvic ring injuries. Insertion of a second supplemental iliosacral screw into the S1 or S2 vertebral body has been widely used. However, clinical fixation failures h...

Descripción completa

Detalles Bibliográficos
Autores principales: Salari, Pooria, Moed, Berton R., Bledsoe, J. Gary
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4633425/
https://www.ncbi.nlm.nih.gov/pubmed/26026285
http://dx.doi.org/10.1007/s10195-015-0357-8
_version_ 1782399191876632576
author Salari, Pooria
Moed, Berton R.
Bledsoe, J. Gary
author_facet Salari, Pooria
Moed, Berton R.
Bledsoe, J. Gary
author_sort Salari, Pooria
collection PubMed
description BACKGROUND: A single iliosacral screw placed into the S1 vertebral body has been shown to be clinically unreliable for certain type C pelvic ring injuries. Insertion of a second supplemental iliosacral screw into the S1 or S2 vertebral body has been widely used. However, clinical fixation failures have been reported using this technique, and a supplemental long iliosacral or transsacral screw has been used. The purpose of this study was to compare the biomechanical effect of a supplemental S1 long iliosacral screw versus a transsacral screw in an unstable type C vertically oriented sacral fracture model. MATERIALS AND METHODS: A type C pelvic ring injury was created in ten osteopenic/osteoporotic cadaver pelves by performing vertical osteotomies through zone 2 of the sacrum and the ipsilateral pubic rami. The sacrum was reduced maintaining a 2-mm fracture gap to simulate a closed-reduction model. All specimens were fixed using one 7.0-mm iliosacral screw into the S1 body. A supplemental long iliosacral screw was placed into the S1 body in five specimens. A supplemental transsacral S1 screw was placed in the other five. Each pelvis underwent 100,000 cycles at 250 N, followed by loading to failure. Vertical displacements at 25,000, 50,000, 75,000, and 100,000 cycles and failure force were recorded. RESULTS: Vertical displacement increased significantly (p < 0.05) within each group with each increase in the number of cycles. However, there was no statistically significant difference between groups in displacement or load to failure. CONCLUSIONS: Although intuitively a transsacral screw may seem to be better than a long iliosacral screw in conveying additional stability to an unstable sacral fracture fixation construct, we were not able to identify any biomechanical advantage of one method over the other. LEVEL OF EVIDENCE: Does not apply—biomechanical study.
format Online
Article
Text
id pubmed-4633425
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-46334252015-11-10 Supplemental S1 fixation for type C pelvic ring injuries: biomechanical study of a long iliosacral versus a transsacral screw Salari, Pooria Moed, Berton R. Bledsoe, J. Gary J Orthop Traumatol Original Article BACKGROUND: A single iliosacral screw placed into the S1 vertebral body has been shown to be clinically unreliable for certain type C pelvic ring injuries. Insertion of a second supplemental iliosacral screw into the S1 or S2 vertebral body has been widely used. However, clinical fixation failures have been reported using this technique, and a supplemental long iliosacral or transsacral screw has been used. The purpose of this study was to compare the biomechanical effect of a supplemental S1 long iliosacral screw versus a transsacral screw in an unstable type C vertically oriented sacral fracture model. MATERIALS AND METHODS: A type C pelvic ring injury was created in ten osteopenic/osteoporotic cadaver pelves by performing vertical osteotomies through zone 2 of the sacrum and the ipsilateral pubic rami. The sacrum was reduced maintaining a 2-mm fracture gap to simulate a closed-reduction model. All specimens were fixed using one 7.0-mm iliosacral screw into the S1 body. A supplemental long iliosacral screw was placed into the S1 body in five specimens. A supplemental transsacral S1 screw was placed in the other five. Each pelvis underwent 100,000 cycles at 250 N, followed by loading to failure. Vertical displacements at 25,000, 50,000, 75,000, and 100,000 cycles and failure force were recorded. RESULTS: Vertical displacement increased significantly (p < 0.05) within each group with each increase in the number of cycles. However, there was no statistically significant difference between groups in displacement or load to failure. CONCLUSIONS: Although intuitively a transsacral screw may seem to be better than a long iliosacral screw in conveying additional stability to an unstable sacral fracture fixation construct, we were not able to identify any biomechanical advantage of one method over the other. LEVEL OF EVIDENCE: Does not apply—biomechanical study. Springer International Publishing 2015-05-31 2015-12 /pmc/articles/PMC4633425/ /pubmed/26026285 http://dx.doi.org/10.1007/s10195-015-0357-8 Text en © The Author(s) 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Article
Salari, Pooria
Moed, Berton R.
Bledsoe, J. Gary
Supplemental S1 fixation for type C pelvic ring injuries: biomechanical study of a long iliosacral versus a transsacral screw
title Supplemental S1 fixation for type C pelvic ring injuries: biomechanical study of a long iliosacral versus a transsacral screw
title_full Supplemental S1 fixation for type C pelvic ring injuries: biomechanical study of a long iliosacral versus a transsacral screw
title_fullStr Supplemental S1 fixation for type C pelvic ring injuries: biomechanical study of a long iliosacral versus a transsacral screw
title_full_unstemmed Supplemental S1 fixation for type C pelvic ring injuries: biomechanical study of a long iliosacral versus a transsacral screw
title_short Supplemental S1 fixation for type C pelvic ring injuries: biomechanical study of a long iliosacral versus a transsacral screw
title_sort supplemental s1 fixation for type c pelvic ring injuries: biomechanical study of a long iliosacral versus a transsacral screw
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4633425/
https://www.ncbi.nlm.nih.gov/pubmed/26026285
http://dx.doi.org/10.1007/s10195-015-0357-8
work_keys_str_mv AT salaripooria supplementals1fixationfortypecpelvicringinjuriesbiomechanicalstudyofalongiliosacralversusatranssacralscrew
AT moedbertonr supplementals1fixationfortypecpelvicringinjuriesbiomechanicalstudyofalongiliosacralversusatranssacralscrew
AT bledsoejgary supplementals1fixationfortypecpelvicringinjuriesbiomechanicalstudyofalongiliosacralversusatranssacralscrew