Cargando…

Inferior vena cava diameters and collapsibility index reveal early volume depletion in a blood donor model

BACKGROUND: Changes of volume status can be readily inferred from variations in diameter of the inferior vena cava (IVC) measured by ultrasound. However the effect of IVC changes following acute blood loss are not fully established. In this study, three different approaches to measuring IVC variable...

Descripción completa

Detalles Bibliográficos
Autores principales: Pasquero, Paolo, Albani, Stefano, Sitia, Elena, Taulaigo, Anna Viola, Borio, Lorenzo, Berchialla, Paola, Castagno, Franco, Porta, Massimo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Milan 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4633475/
https://www.ncbi.nlm.nih.gov/pubmed/26537114
http://dx.doi.org/10.1186/s13089-015-0034-4
_version_ 1782399203343859712
author Pasquero, Paolo
Albani, Stefano
Sitia, Elena
Taulaigo, Anna Viola
Borio, Lorenzo
Berchialla, Paola
Castagno, Franco
Porta, Massimo
author_facet Pasquero, Paolo
Albani, Stefano
Sitia, Elena
Taulaigo, Anna Viola
Borio, Lorenzo
Berchialla, Paola
Castagno, Franco
Porta, Massimo
author_sort Pasquero, Paolo
collection PubMed
description BACKGROUND: Changes of volume status can be readily inferred from variations in diameter of the inferior vena cava (IVC) measured by ultrasound. However the effect of IVC changes following acute blood loss are not fully established. In this study, three different approaches to measuring IVC variables were compared in healthy blood donors, as a model of acute volume depletion, in order to establish their relative ability to detect acute blood loss. METHODS: Inspiratory and expiratory IVC diameters were measured before and after blood donation in hepatic long axis, hepatic short axis and renal short axis views using a 2–5 MHz curvilinear probe. All measurements were recorded and examined in real-time and post-processing sessions. RESULTS: All windows performed satisfactorily but the renal window approach was feasible in only 30 out of 47 subjects. After blood donation, IVC diameters decreased in hepatic long axis, hepatic short axis and renal short axis (expiratory: −19.9, −18.0, −26.5 %; CI 95 %: 14.5–24.1; 13.1–22.9; 16.0–35.9, respectively) (inspiratory: −31.1, −31.6, −36.5 %; CI 95 %: 21.3–40.1; 18.8–45.2; 23.4–46.0, respectively), whereas the IVC collapsibility index increased by 21.6, 22.6 and 19.3 % (CI 95 %: 11.6–42.9; 18.5–39.5; 7.7–30.0). IVC diameters appeared to return to pre-donation values within 20 min but this was only detected by the hepatic long axis view. CONCLUSIONS: IVC diameter and collapsibility index variations, as measured in M mode, consistently detect volume changes after blood donation. The longitudinal mid-hepatic approach performed better by allowing a panoramic view, avoiding anatomical aberrancies at fixed points and permitting to identify the best possible perpendicular plane to the IVC. In addition, it was able to detect time-dependent physiological volume replacement. In contrast, in our hands, the renal window could not be visualized consistently well.
format Online
Article
Text
id pubmed-4633475
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Springer Milan
record_format MEDLINE/PubMed
spelling pubmed-46334752015-11-10 Inferior vena cava diameters and collapsibility index reveal early volume depletion in a blood donor model Pasquero, Paolo Albani, Stefano Sitia, Elena Taulaigo, Anna Viola Borio, Lorenzo Berchialla, Paola Castagno, Franco Porta, Massimo Crit Ultrasound J Original Article BACKGROUND: Changes of volume status can be readily inferred from variations in diameter of the inferior vena cava (IVC) measured by ultrasound. However the effect of IVC changes following acute blood loss are not fully established. In this study, three different approaches to measuring IVC variables were compared in healthy blood donors, as a model of acute volume depletion, in order to establish their relative ability to detect acute blood loss. METHODS: Inspiratory and expiratory IVC diameters were measured before and after blood donation in hepatic long axis, hepatic short axis and renal short axis views using a 2–5 MHz curvilinear probe. All measurements were recorded and examined in real-time and post-processing sessions. RESULTS: All windows performed satisfactorily but the renal window approach was feasible in only 30 out of 47 subjects. After blood donation, IVC diameters decreased in hepatic long axis, hepatic short axis and renal short axis (expiratory: −19.9, −18.0, −26.5 %; CI 95 %: 14.5–24.1; 13.1–22.9; 16.0–35.9, respectively) (inspiratory: −31.1, −31.6, −36.5 %; CI 95 %: 21.3–40.1; 18.8–45.2; 23.4–46.0, respectively), whereas the IVC collapsibility index increased by 21.6, 22.6 and 19.3 % (CI 95 %: 11.6–42.9; 18.5–39.5; 7.7–30.0). IVC diameters appeared to return to pre-donation values within 20 min but this was only detected by the hepatic long axis view. CONCLUSIONS: IVC diameter and collapsibility index variations, as measured in M mode, consistently detect volume changes after blood donation. The longitudinal mid-hepatic approach performed better by allowing a panoramic view, avoiding anatomical aberrancies at fixed points and permitting to identify the best possible perpendicular plane to the IVC. In addition, it was able to detect time-dependent physiological volume replacement. In contrast, in our hands, the renal window could not be visualized consistently well. Springer Milan 2015-11-04 /pmc/articles/PMC4633475/ /pubmed/26537114 http://dx.doi.org/10.1186/s13089-015-0034-4 Text en © Pasquero et al. 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Article
Pasquero, Paolo
Albani, Stefano
Sitia, Elena
Taulaigo, Anna Viola
Borio, Lorenzo
Berchialla, Paola
Castagno, Franco
Porta, Massimo
Inferior vena cava diameters and collapsibility index reveal early volume depletion in a blood donor model
title Inferior vena cava diameters and collapsibility index reveal early volume depletion in a blood donor model
title_full Inferior vena cava diameters and collapsibility index reveal early volume depletion in a blood donor model
title_fullStr Inferior vena cava diameters and collapsibility index reveal early volume depletion in a blood donor model
title_full_unstemmed Inferior vena cava diameters and collapsibility index reveal early volume depletion in a blood donor model
title_short Inferior vena cava diameters and collapsibility index reveal early volume depletion in a blood donor model
title_sort inferior vena cava diameters and collapsibility index reveal early volume depletion in a blood donor model
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4633475/
https://www.ncbi.nlm.nih.gov/pubmed/26537114
http://dx.doi.org/10.1186/s13089-015-0034-4
work_keys_str_mv AT pasqueropaolo inferiorvenacavadiametersandcollapsibilityindexrevealearlyvolumedepletioninablooddonormodel
AT albanistefano inferiorvenacavadiametersandcollapsibilityindexrevealearlyvolumedepletioninablooddonormodel
AT sitiaelena inferiorvenacavadiametersandcollapsibilityindexrevealearlyvolumedepletioninablooddonormodel
AT taulaigoannaviola inferiorvenacavadiametersandcollapsibilityindexrevealearlyvolumedepletioninablooddonormodel
AT boriolorenzo inferiorvenacavadiametersandcollapsibilityindexrevealearlyvolumedepletioninablooddonormodel
AT berchiallapaola inferiorvenacavadiametersandcollapsibilityindexrevealearlyvolumedepletioninablooddonormodel
AT castagnofranco inferiorvenacavadiametersandcollapsibilityindexrevealearlyvolumedepletioninablooddonormodel
AT portamassimo inferiorvenacavadiametersandcollapsibilityindexrevealearlyvolumedepletioninablooddonormodel