Cargando…

Performance Evaluation of Wearable Sensor Systems: A Case Study in Moderate-Scale Deployment in Hospital Environment

A wearable sensor system enables continuous and remote health monitoring and is widely considered as the next generation of healthcare technology. The performance, the packet error rate (PER) in particular, of a wearable sensor system may deteriorate due to a number of factors, particularly the inte...

Descripción completa

Detalles Bibliográficos
Autores principales: Sun, Wen, Ge, Yu, Zhang, Zhiqiang, Wong, Wai-Choong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4634400/
https://www.ncbi.nlm.nih.gov/pubmed/26426015
http://dx.doi.org/10.3390/s151024977
_version_ 1782399347250429952
author Sun, Wen
Ge, Yu
Zhang, Zhiqiang
Wong, Wai-Choong
author_facet Sun, Wen
Ge, Yu
Zhang, Zhiqiang
Wong, Wai-Choong
author_sort Sun, Wen
collection PubMed
description A wearable sensor system enables continuous and remote health monitoring and is widely considered as the next generation of healthcare technology. The performance, the packet error rate (PER) in particular, of a wearable sensor system may deteriorate due to a number of factors, particularly the interference from the other wearable sensor systems in the vicinity. We systematically evaluate the performance of the wearable sensor system in terms of PER in the presence of such interference in this paper. The factors that affect the performance of the wearable sensor system, such as density, traffic load, and transmission power in a realistic moderate-scale deployment case in hospital are all considered. Simulation results show that with 20% duty cycle, only 68.5% of data transmission can achieve the targeted reliability requirement (PER is less than 0.05) even in the off-peak period in hospital. We then suggest some interference mitigation schemes based on the performance evaluation results in the case study.
format Online
Article
Text
id pubmed-4634400
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-46344002015-11-23 Performance Evaluation of Wearable Sensor Systems: A Case Study in Moderate-Scale Deployment in Hospital Environment Sun, Wen Ge, Yu Zhang, Zhiqiang Wong, Wai-Choong Sensors (Basel) Article A wearable sensor system enables continuous and remote health monitoring and is widely considered as the next generation of healthcare technology. The performance, the packet error rate (PER) in particular, of a wearable sensor system may deteriorate due to a number of factors, particularly the interference from the other wearable sensor systems in the vicinity. We systematically evaluate the performance of the wearable sensor system in terms of PER in the presence of such interference in this paper. The factors that affect the performance of the wearable sensor system, such as density, traffic load, and transmission power in a realistic moderate-scale deployment case in hospital are all considered. Simulation results show that with 20% duty cycle, only 68.5% of data transmission can achieve the targeted reliability requirement (PER is less than 0.05) even in the off-peak period in hospital. We then suggest some interference mitigation schemes based on the performance evaluation results in the case study. MDPI 2015-09-25 /pmc/articles/PMC4634400/ /pubmed/26426015 http://dx.doi.org/10.3390/s151024977 Text en © 2015 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Sun, Wen
Ge, Yu
Zhang, Zhiqiang
Wong, Wai-Choong
Performance Evaluation of Wearable Sensor Systems: A Case Study in Moderate-Scale Deployment in Hospital Environment
title Performance Evaluation of Wearable Sensor Systems: A Case Study in Moderate-Scale Deployment in Hospital Environment
title_full Performance Evaluation of Wearable Sensor Systems: A Case Study in Moderate-Scale Deployment in Hospital Environment
title_fullStr Performance Evaluation of Wearable Sensor Systems: A Case Study in Moderate-Scale Deployment in Hospital Environment
title_full_unstemmed Performance Evaluation of Wearable Sensor Systems: A Case Study in Moderate-Scale Deployment in Hospital Environment
title_short Performance Evaluation of Wearable Sensor Systems: A Case Study in Moderate-Scale Deployment in Hospital Environment
title_sort performance evaluation of wearable sensor systems: a case study in moderate-scale deployment in hospital environment
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4634400/
https://www.ncbi.nlm.nih.gov/pubmed/26426015
http://dx.doi.org/10.3390/s151024977
work_keys_str_mv AT sunwen performanceevaluationofwearablesensorsystemsacasestudyinmoderatescaledeploymentinhospitalenvironment
AT geyu performanceevaluationofwearablesensorsystemsacasestudyinmoderatescaledeploymentinhospitalenvironment
AT zhangzhiqiang performanceevaluationofwearablesensorsystemsacasestudyinmoderatescaledeploymentinhospitalenvironment
AT wongwaichoong performanceevaluationofwearablesensorsystemsacasestudyinmoderatescaledeploymentinhospitalenvironment