Cargando…

Fully Integrated Low-Noise Readout Circuit with Automatic Offset Cancellation Loop for Capacitive Microsensors

Capacitive sensing schemes are widely used for various microsensors; however, such microsensors suffer from severe parasitic capacitance problems. This paper presents a fully integrated low-noise readout circuit with automatic offset cancellation loop (AOCL) for capacitive microsensors. The output o...

Descripción completa

Detalles Bibliográficos
Autores principales: Song, Haryong, Park, Yunjong, Kim, Hyungseup, Cho, Dong-il Dan, Ko, Hyoungho
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4634440/
https://www.ncbi.nlm.nih.gov/pubmed/26473877
http://dx.doi.org/10.3390/s151026009
_version_ 1782399356540813312
author Song, Haryong
Park, Yunjong
Kim, Hyungseup
Cho, Dong-il Dan
Ko, Hyoungho
author_facet Song, Haryong
Park, Yunjong
Kim, Hyungseup
Cho, Dong-il Dan
Ko, Hyoungho
author_sort Song, Haryong
collection PubMed
description Capacitive sensing schemes are widely used for various microsensors; however, such microsensors suffer from severe parasitic capacitance problems. This paper presents a fully integrated low-noise readout circuit with automatic offset cancellation loop (AOCL) for capacitive microsensors. The output offsets of the capacitive sensing chain due to the parasitic capacitances and process variations are automatically removed using AOCL. The AOCL generates electrically equivalent offset capacitance and enables charge-domain fine calibration using a 10-bit R-2R digital-to-analog converter, charge-transfer switches, and a charge-storing capacitor. The AOCL cancels the unwanted offset by binary-search algorithm based on 10-bit successive approximation register (SAR) logic. The chip is implemented using 0.18 μm complementary metal-oxide-semiconductor (CMOS) process with an active area of 1.76 mm(2). The power consumption is 220 μW with 3.3 V supply. The input parasitic capacitances within the range of −250 fF to 250 fF can be cancelled out automatically, and the required calibration time is lower than 10 ms.
format Online
Article
Text
id pubmed-4634440
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-46344402015-11-23 Fully Integrated Low-Noise Readout Circuit with Automatic Offset Cancellation Loop for Capacitive Microsensors Song, Haryong Park, Yunjong Kim, Hyungseup Cho, Dong-il Dan Ko, Hyoungho Sensors (Basel) Article Capacitive sensing schemes are widely used for various microsensors; however, such microsensors suffer from severe parasitic capacitance problems. This paper presents a fully integrated low-noise readout circuit with automatic offset cancellation loop (AOCL) for capacitive microsensors. The output offsets of the capacitive sensing chain due to the parasitic capacitances and process variations are automatically removed using AOCL. The AOCL generates electrically equivalent offset capacitance and enables charge-domain fine calibration using a 10-bit R-2R digital-to-analog converter, charge-transfer switches, and a charge-storing capacitor. The AOCL cancels the unwanted offset by binary-search algorithm based on 10-bit successive approximation register (SAR) logic. The chip is implemented using 0.18 μm complementary metal-oxide-semiconductor (CMOS) process with an active area of 1.76 mm(2). The power consumption is 220 μW with 3.3 V supply. The input parasitic capacitances within the range of −250 fF to 250 fF can be cancelled out automatically, and the required calibration time is lower than 10 ms. MDPI 2015-10-14 /pmc/articles/PMC4634440/ /pubmed/26473877 http://dx.doi.org/10.3390/s151026009 Text en © 2015 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Song, Haryong
Park, Yunjong
Kim, Hyungseup
Cho, Dong-il Dan
Ko, Hyoungho
Fully Integrated Low-Noise Readout Circuit with Automatic Offset Cancellation Loop for Capacitive Microsensors
title Fully Integrated Low-Noise Readout Circuit with Automatic Offset Cancellation Loop for Capacitive Microsensors
title_full Fully Integrated Low-Noise Readout Circuit with Automatic Offset Cancellation Loop for Capacitive Microsensors
title_fullStr Fully Integrated Low-Noise Readout Circuit with Automatic Offset Cancellation Loop for Capacitive Microsensors
title_full_unstemmed Fully Integrated Low-Noise Readout Circuit with Automatic Offset Cancellation Loop for Capacitive Microsensors
title_short Fully Integrated Low-Noise Readout Circuit with Automatic Offset Cancellation Loop for Capacitive Microsensors
title_sort fully integrated low-noise readout circuit with automatic offset cancellation loop for capacitive microsensors
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4634440/
https://www.ncbi.nlm.nih.gov/pubmed/26473877
http://dx.doi.org/10.3390/s151026009
work_keys_str_mv AT songharyong fullyintegratedlownoisereadoutcircuitwithautomaticoffsetcancellationloopforcapacitivemicrosensors
AT parkyunjong fullyintegratedlownoisereadoutcircuitwithautomaticoffsetcancellationloopforcapacitivemicrosensors
AT kimhyungseup fullyintegratedlownoisereadoutcircuitwithautomaticoffsetcancellationloopforcapacitivemicrosensors
AT chodongildan fullyintegratedlownoisereadoutcircuitwithautomaticoffsetcancellationloopforcapacitivemicrosensors
AT kohyoungho fullyintegratedlownoisereadoutcircuitwithautomaticoffsetcancellationloopforcapacitivemicrosensors