Fully Integrated Low-Noise Readout Circuit with Automatic Offset Cancellation Loop for Capacitive Microsensors
Capacitive sensing schemes are widely used for various microsensors; however, such microsensors suffer from severe parasitic capacitance problems. This paper presents a fully integrated low-noise readout circuit with automatic offset cancellation loop (AOCL) for capacitive microsensors. The output o...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4634440/ https://www.ncbi.nlm.nih.gov/pubmed/26473877 http://dx.doi.org/10.3390/s151026009 |
_version_ | 1782399356540813312 |
---|---|
author | Song, Haryong Park, Yunjong Kim, Hyungseup Cho, Dong-il Dan Ko, Hyoungho |
author_facet | Song, Haryong Park, Yunjong Kim, Hyungseup Cho, Dong-il Dan Ko, Hyoungho |
author_sort | Song, Haryong |
collection | PubMed |
description | Capacitive sensing schemes are widely used for various microsensors; however, such microsensors suffer from severe parasitic capacitance problems. This paper presents a fully integrated low-noise readout circuit with automatic offset cancellation loop (AOCL) for capacitive microsensors. The output offsets of the capacitive sensing chain due to the parasitic capacitances and process variations are automatically removed using AOCL. The AOCL generates electrically equivalent offset capacitance and enables charge-domain fine calibration using a 10-bit R-2R digital-to-analog converter, charge-transfer switches, and a charge-storing capacitor. The AOCL cancels the unwanted offset by binary-search algorithm based on 10-bit successive approximation register (SAR) logic. The chip is implemented using 0.18 μm complementary metal-oxide-semiconductor (CMOS) process with an active area of 1.76 mm(2). The power consumption is 220 μW with 3.3 V supply. The input parasitic capacitances within the range of −250 fF to 250 fF can be cancelled out automatically, and the required calibration time is lower than 10 ms. |
format | Online Article Text |
id | pubmed-4634440 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-46344402015-11-23 Fully Integrated Low-Noise Readout Circuit with Automatic Offset Cancellation Loop for Capacitive Microsensors Song, Haryong Park, Yunjong Kim, Hyungseup Cho, Dong-il Dan Ko, Hyoungho Sensors (Basel) Article Capacitive sensing schemes are widely used for various microsensors; however, such microsensors suffer from severe parasitic capacitance problems. This paper presents a fully integrated low-noise readout circuit with automatic offset cancellation loop (AOCL) for capacitive microsensors. The output offsets of the capacitive sensing chain due to the parasitic capacitances and process variations are automatically removed using AOCL. The AOCL generates electrically equivalent offset capacitance and enables charge-domain fine calibration using a 10-bit R-2R digital-to-analog converter, charge-transfer switches, and a charge-storing capacitor. The AOCL cancels the unwanted offset by binary-search algorithm based on 10-bit successive approximation register (SAR) logic. The chip is implemented using 0.18 μm complementary metal-oxide-semiconductor (CMOS) process with an active area of 1.76 mm(2). The power consumption is 220 μW with 3.3 V supply. The input parasitic capacitances within the range of −250 fF to 250 fF can be cancelled out automatically, and the required calibration time is lower than 10 ms. MDPI 2015-10-14 /pmc/articles/PMC4634440/ /pubmed/26473877 http://dx.doi.org/10.3390/s151026009 Text en © 2015 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Song, Haryong Park, Yunjong Kim, Hyungseup Cho, Dong-il Dan Ko, Hyoungho Fully Integrated Low-Noise Readout Circuit with Automatic Offset Cancellation Loop for Capacitive Microsensors |
title | Fully Integrated Low-Noise Readout Circuit with Automatic Offset Cancellation Loop for Capacitive Microsensors |
title_full | Fully Integrated Low-Noise Readout Circuit with Automatic Offset Cancellation Loop for Capacitive Microsensors |
title_fullStr | Fully Integrated Low-Noise Readout Circuit with Automatic Offset Cancellation Loop for Capacitive Microsensors |
title_full_unstemmed | Fully Integrated Low-Noise Readout Circuit with Automatic Offset Cancellation Loop for Capacitive Microsensors |
title_short | Fully Integrated Low-Noise Readout Circuit with Automatic Offset Cancellation Loop for Capacitive Microsensors |
title_sort | fully integrated low-noise readout circuit with automatic offset cancellation loop for capacitive microsensors |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4634440/ https://www.ncbi.nlm.nih.gov/pubmed/26473877 http://dx.doi.org/10.3390/s151026009 |
work_keys_str_mv | AT songharyong fullyintegratedlownoisereadoutcircuitwithautomaticoffsetcancellationloopforcapacitivemicrosensors AT parkyunjong fullyintegratedlownoisereadoutcircuitwithautomaticoffsetcancellationloopforcapacitivemicrosensors AT kimhyungseup fullyintegratedlownoisereadoutcircuitwithautomaticoffsetcancellationloopforcapacitivemicrosensors AT chodongildan fullyintegratedlownoisereadoutcircuitwithautomaticoffsetcancellationloopforcapacitivemicrosensors AT kohyoungho fullyintegratedlownoisereadoutcircuitwithautomaticoffsetcancellationloopforcapacitivemicrosensors |