Cargando…
Maximum Measurement Range and Accuracy of SAW Reflective Delay Line Sensors
In a surface acoustic wave (SAW) wireless sensor with a reflective delay line structure, three reflectors are often used to eliminate 2π ambiguity of phase measurement. The maximum range of the measured parameter and the maximum accuracy have recently been attracting much research attention. In this...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4634512/ https://www.ncbi.nlm.nih.gov/pubmed/26492251 http://dx.doi.org/10.3390/s151026643 |
_version_ | 1782399373146062848 |
---|---|
author | Zheng, Zehua Han, Tao Qin, Peng |
author_facet | Zheng, Zehua Han, Tao Qin, Peng |
author_sort | Zheng, Zehua |
collection | PubMed |
description | In a surface acoustic wave (SAW) wireless sensor with a reflective delay line structure, three reflectors are often used to eliminate 2π ambiguity of phase measurement. The maximum range of the measured parameter and the maximum accuracy have recently been attracting much research attention. In this paper, an analytical formula for all the factors influencing the measurement range and accuracy of the delay line SAW sensor are deduced for the first time. The factors include: the sensor sensitivity, the topology of the delay line, the available wireless bandwidth and the allowed maximum phase measuring error of the reading system, which is easier to retrieve and more fully describes the possible noises than SNR. Additionally, many designers believe that increasing the reflector could improve accuracy continuously or realize multi-resolution measurement. However, they ignore some certain criteria that the reflector location must satisfy. The reachable maximum accuracy by every increase of a reflector is also presented. A SAW temperature sensor system using 128° YX-LiNbO(3) is designed to verify the above theoretical analysis. |
format | Online Article Text |
id | pubmed-4634512 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-46345122015-11-23 Maximum Measurement Range and Accuracy of SAW Reflective Delay Line Sensors Zheng, Zehua Han, Tao Qin, Peng Sensors (Basel) Article In a surface acoustic wave (SAW) wireless sensor with a reflective delay line structure, three reflectors are often used to eliminate 2π ambiguity of phase measurement. The maximum range of the measured parameter and the maximum accuracy have recently been attracting much research attention. In this paper, an analytical formula for all the factors influencing the measurement range and accuracy of the delay line SAW sensor are deduced for the first time. The factors include: the sensor sensitivity, the topology of the delay line, the available wireless bandwidth and the allowed maximum phase measuring error of the reading system, which is easier to retrieve and more fully describes the possible noises than SNR. Additionally, many designers believe that increasing the reflector could improve accuracy continuously or realize multi-resolution measurement. However, they ignore some certain criteria that the reflector location must satisfy. The reachable maximum accuracy by every increase of a reflector is also presented. A SAW temperature sensor system using 128° YX-LiNbO(3) is designed to verify the above theoretical analysis. MDPI 2015-10-20 /pmc/articles/PMC4634512/ /pubmed/26492251 http://dx.doi.org/10.3390/s151026643 Text en © 2015 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Zheng, Zehua Han, Tao Qin, Peng Maximum Measurement Range and Accuracy of SAW Reflective Delay Line Sensors |
title | Maximum Measurement Range and Accuracy of SAW Reflective Delay Line Sensors |
title_full | Maximum Measurement Range and Accuracy of SAW Reflective Delay Line Sensors |
title_fullStr | Maximum Measurement Range and Accuracy of SAW Reflective Delay Line Sensors |
title_full_unstemmed | Maximum Measurement Range and Accuracy of SAW Reflective Delay Line Sensors |
title_short | Maximum Measurement Range and Accuracy of SAW Reflective Delay Line Sensors |
title_sort | maximum measurement range and accuracy of saw reflective delay line sensors |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4634512/ https://www.ncbi.nlm.nih.gov/pubmed/26492251 http://dx.doi.org/10.3390/s151026643 |
work_keys_str_mv | AT zhengzehua maximummeasurementrangeandaccuracyofsawreflectivedelaylinesensors AT hantao maximummeasurementrangeandaccuracyofsawreflectivedelaylinesensors AT qinpeng maximummeasurementrangeandaccuracyofsawreflectivedelaylinesensors |