Cargando…
Fast T2 gradient-spin-echo (T2-GraSE) mapping for myocardial edema quantification: first in vivo validation in a porcine model of ischemia/reperfusion
BACKGROUND: Several T2-mapping sequences have been recently proposed to quantify myocardial edema by providing T2 relaxation time values. However, no T2-mapping sequence has ever been validated against actual myocardial water content for edema detection. In addition, these T2-mapping sequences are e...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4634909/ https://www.ncbi.nlm.nih.gov/pubmed/26538198 http://dx.doi.org/10.1186/s12968-015-0199-9 |
_version_ | 1782399437003292672 |
---|---|
author | Fernández-Jiménez, Rodrigo Sánchez-González, Javier Aguero, Jaume del Trigo, María Galán-Arriola, Carlos Fuster, Valentin Ibáñez, Borja |
author_facet | Fernández-Jiménez, Rodrigo Sánchez-González, Javier Aguero, Jaume del Trigo, María Galán-Arriola, Carlos Fuster, Valentin Ibáñez, Borja |
author_sort | Fernández-Jiménez, Rodrigo |
collection | PubMed |
description | BACKGROUND: Several T2-mapping sequences have been recently proposed to quantify myocardial edema by providing T2 relaxation time values. However, no T2-mapping sequence has ever been validated against actual myocardial water content for edema detection. In addition, these T2-mapping sequences are either time-consuming or require specialized software for data acquisition and/or post-processing, factors impeding their routine clinical use. Our objective was to obtain in vivo validation of a sequence for fast and accurate myocardial T2-mapping (T2 gradient-spin-echo [GraSE]) that can be easily integrated in routine protocols. METHODS: The study population comprised 25 pigs. Closed-chest 40 min ischemia/reperfusion was performed in 20 pigs. Pigs were sacrificed at 120 min (n = 5), 24 h (n = 5), 4 days (n = 5) and 7 days (n = 5) after reperfusion, and heart tissue extracted for quantification of myocardial water content. For the evaluation of T2 relaxation time, cardiovascular magnetic resonance (CMR) scans, including T2 turbo-spin-echo (T2-TSE, reference standard) mapping and T2-GraSE mapping, were performed at baseline and at every follow-up until sacrifice. Five additional pigs were sacrificed after baseline CMR study and served as controls. RESULTS: Acquisition of T2-GraSE mapping was significantly (3-fold) faster than conventional T2-TSE mapping. Myocardial T2 relaxation measurements performed by T2-TSE and T2-GraSE mapping demonstrated an almost perfect correlation (R(2) = 0.99) and agreement with no systematic error between techniques. The two T2-mapping sequences showed similarly good correlations with myocardial water content: R(2) = 0.75 and R(2) = 0.73 for T2-TSE and T2-GraSE mapping, respectively. CONCLUSIONS: We present the first in vivo validation of T2-mapping to assess myocardial edema. Given its shorter acquisition time and no requirement for specific software for data acquisition or post-processing, fast T2-GraSE mapping of the myocardium offers an attractive alternative to current CMR sequences for T2 quantification. |
format | Online Article Text |
id | pubmed-4634909 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-46349092015-11-10 Fast T2 gradient-spin-echo (T2-GraSE) mapping for myocardial edema quantification: first in vivo validation in a porcine model of ischemia/reperfusion Fernández-Jiménez, Rodrigo Sánchez-González, Javier Aguero, Jaume del Trigo, María Galán-Arriola, Carlos Fuster, Valentin Ibáñez, Borja J Cardiovasc Magn Reson Research BACKGROUND: Several T2-mapping sequences have been recently proposed to quantify myocardial edema by providing T2 relaxation time values. However, no T2-mapping sequence has ever been validated against actual myocardial water content for edema detection. In addition, these T2-mapping sequences are either time-consuming or require specialized software for data acquisition and/or post-processing, factors impeding their routine clinical use. Our objective was to obtain in vivo validation of a sequence for fast and accurate myocardial T2-mapping (T2 gradient-spin-echo [GraSE]) that can be easily integrated in routine protocols. METHODS: The study population comprised 25 pigs. Closed-chest 40 min ischemia/reperfusion was performed in 20 pigs. Pigs were sacrificed at 120 min (n = 5), 24 h (n = 5), 4 days (n = 5) and 7 days (n = 5) after reperfusion, and heart tissue extracted for quantification of myocardial water content. For the evaluation of T2 relaxation time, cardiovascular magnetic resonance (CMR) scans, including T2 turbo-spin-echo (T2-TSE, reference standard) mapping and T2-GraSE mapping, were performed at baseline and at every follow-up until sacrifice. Five additional pigs were sacrificed after baseline CMR study and served as controls. RESULTS: Acquisition of T2-GraSE mapping was significantly (3-fold) faster than conventional T2-TSE mapping. Myocardial T2 relaxation measurements performed by T2-TSE and T2-GraSE mapping demonstrated an almost perfect correlation (R(2) = 0.99) and agreement with no systematic error between techniques. The two T2-mapping sequences showed similarly good correlations with myocardial water content: R(2) = 0.75 and R(2) = 0.73 for T2-TSE and T2-GraSE mapping, respectively. CONCLUSIONS: We present the first in vivo validation of T2-mapping to assess myocardial edema. Given its shorter acquisition time and no requirement for specific software for data acquisition or post-processing, fast T2-GraSE mapping of the myocardium offers an attractive alternative to current CMR sequences for T2 quantification. BioMed Central 2015-11-04 /pmc/articles/PMC4634909/ /pubmed/26538198 http://dx.doi.org/10.1186/s12968-015-0199-9 Text en © Fernández-Jiménez et al. 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Fernández-Jiménez, Rodrigo Sánchez-González, Javier Aguero, Jaume del Trigo, María Galán-Arriola, Carlos Fuster, Valentin Ibáñez, Borja Fast T2 gradient-spin-echo (T2-GraSE) mapping for myocardial edema quantification: first in vivo validation in a porcine model of ischemia/reperfusion |
title | Fast T2 gradient-spin-echo (T2-GraSE) mapping for myocardial edema quantification: first in vivo validation in a porcine model of ischemia/reperfusion |
title_full | Fast T2 gradient-spin-echo (T2-GraSE) mapping for myocardial edema quantification: first in vivo validation in a porcine model of ischemia/reperfusion |
title_fullStr | Fast T2 gradient-spin-echo (T2-GraSE) mapping for myocardial edema quantification: first in vivo validation in a porcine model of ischemia/reperfusion |
title_full_unstemmed | Fast T2 gradient-spin-echo (T2-GraSE) mapping for myocardial edema quantification: first in vivo validation in a porcine model of ischemia/reperfusion |
title_short | Fast T2 gradient-spin-echo (T2-GraSE) mapping for myocardial edema quantification: first in vivo validation in a porcine model of ischemia/reperfusion |
title_sort | fast t2 gradient-spin-echo (t2-grase) mapping for myocardial edema quantification: first in vivo validation in a porcine model of ischemia/reperfusion |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4634909/ https://www.ncbi.nlm.nih.gov/pubmed/26538198 http://dx.doi.org/10.1186/s12968-015-0199-9 |
work_keys_str_mv | AT fernandezjimenezrodrigo fastt2gradientspinechot2grasemappingformyocardialedemaquantificationfirstinvivovalidationinaporcinemodelofischemiareperfusion AT sanchezgonzalezjavier fastt2gradientspinechot2grasemappingformyocardialedemaquantificationfirstinvivovalidationinaporcinemodelofischemiareperfusion AT aguerojaume fastt2gradientspinechot2grasemappingformyocardialedemaquantificationfirstinvivovalidationinaporcinemodelofischemiareperfusion AT deltrigomaria fastt2gradientspinechot2grasemappingformyocardialedemaquantificationfirstinvivovalidationinaporcinemodelofischemiareperfusion AT galanarriolacarlos fastt2gradientspinechot2grasemappingformyocardialedemaquantificationfirstinvivovalidationinaporcinemodelofischemiareperfusion AT fustervalentin fastt2gradientspinechot2grasemappingformyocardialedemaquantificationfirstinvivovalidationinaporcinemodelofischemiareperfusion AT ibanezborja fastt2gradientspinechot2grasemappingformyocardialedemaquantificationfirstinvivovalidationinaporcinemodelofischemiareperfusion |