Cargando…

Peri-implant crevicular fluid levels of cathepsin-K, RANKL, and OPG around standard, short, and mini dental implants after prosthodontic loading

PURPOSE: Despite the high success rates of endosseous dental implants, their placement is restricted according to the height and volume of bone available. The use of short or mini dental implants could be one way to overcome this limitation. Thus, this study aimed to compare standard, short, and min...

Descripción completa

Detalles Bibliográficos
Autores principales: Alan, Raif, Marakoğlu, İsmail, Haliloğlu, Seyfullah
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Academy of Periodontology 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4635438/
https://www.ncbi.nlm.nih.gov/pubmed/26550525
http://dx.doi.org/10.5051/jpis.2015.45.5.169
_version_ 1782399506689556480
author Alan, Raif
Marakoğlu, İsmail
Haliloğlu, Seyfullah
author_facet Alan, Raif
Marakoğlu, İsmail
Haliloğlu, Seyfullah
author_sort Alan, Raif
collection PubMed
description PURPOSE: Despite the high success rates of endosseous dental implants, their placement is restricted according to the height and volume of bone available. The use of short or mini dental implants could be one way to overcome this limitation. Thus, this study aimed to compare standard, short, and mini dental implants with regard to associated clinical parameters and peri-implant crevicular fluid (PICF) levels of cathepsin -K (CTSK), RANK ligand (RANKL), and osteoprotegerin (OPG), after prosthodontic loading. METHODS: A total of 78 non-submerged implants (Euroteknika, Aesthetica(+2), Sallanches, France) were installed in 30 subjects (13 male, 17 female; range, 26-62 years) who visited the clinic of the Periodontology Department, Faculty of Dentistry, Selcuk University. Sampling and measurements were performed on the loading date (baseline) and 2, 14, and 90 days after loading. Assessment of the peri-implant status for the implant sites was performed using the pocket probing depth (PPD), modified plaque index, modified gingival index, modified sulcular bleeding index, and radiographic signs of bone loss. PICF samples collected from each implant were evaluated for CTSK, RANKL, and OPG levels using the ELISA method. Keratinized tissue and marginal bone loss (MBL) were also noted. RESULTS: Clinical parameters statistically significantly increased in each group but did not show statistical differences between groups without PPD. Although implant groups showed a higher MBL in the upper jaw, only the standard dental group demonstrated a statistically significant difference. At 90 days, the OPG: sRANKL ratio and total amounts of CTSK for each group did not differ from baseline. CONCLUSIONS: Within the limitations of this study, both short and mini dental implants were achieving the same outcomes as the standard dental implants in the early period after loading.
format Online
Article
Text
id pubmed-4635438
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Korean Academy of Periodontology
record_format MEDLINE/PubMed
spelling pubmed-46354382015-11-06 Peri-implant crevicular fluid levels of cathepsin-K, RANKL, and OPG around standard, short, and mini dental implants after prosthodontic loading Alan, Raif Marakoğlu, İsmail Haliloğlu, Seyfullah J Periodontal Implant Sci Research Article PURPOSE: Despite the high success rates of endosseous dental implants, their placement is restricted according to the height and volume of bone available. The use of short or mini dental implants could be one way to overcome this limitation. Thus, this study aimed to compare standard, short, and mini dental implants with regard to associated clinical parameters and peri-implant crevicular fluid (PICF) levels of cathepsin -K (CTSK), RANK ligand (RANKL), and osteoprotegerin (OPG), after prosthodontic loading. METHODS: A total of 78 non-submerged implants (Euroteknika, Aesthetica(+2), Sallanches, France) were installed in 30 subjects (13 male, 17 female; range, 26-62 years) who visited the clinic of the Periodontology Department, Faculty of Dentistry, Selcuk University. Sampling and measurements were performed on the loading date (baseline) and 2, 14, and 90 days after loading. Assessment of the peri-implant status for the implant sites was performed using the pocket probing depth (PPD), modified plaque index, modified gingival index, modified sulcular bleeding index, and radiographic signs of bone loss. PICF samples collected from each implant were evaluated for CTSK, RANKL, and OPG levels using the ELISA method. Keratinized tissue and marginal bone loss (MBL) were also noted. RESULTS: Clinical parameters statistically significantly increased in each group but did not show statistical differences between groups without PPD. Although implant groups showed a higher MBL in the upper jaw, only the standard dental group demonstrated a statistically significant difference. At 90 days, the OPG: sRANKL ratio and total amounts of CTSK for each group did not differ from baseline. CONCLUSIONS: Within the limitations of this study, both short and mini dental implants were achieving the same outcomes as the standard dental implants in the early period after loading. Korean Academy of Periodontology 2015-10 2015-10-26 /pmc/articles/PMC4635438/ /pubmed/26550525 http://dx.doi.org/10.5051/jpis.2015.45.5.169 Text en Copyright © 2015 Korean Academy of Periodontology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/).
spellingShingle Research Article
Alan, Raif
Marakoğlu, İsmail
Haliloğlu, Seyfullah
Peri-implant crevicular fluid levels of cathepsin-K, RANKL, and OPG around standard, short, and mini dental implants after prosthodontic loading
title Peri-implant crevicular fluid levels of cathepsin-K, RANKL, and OPG around standard, short, and mini dental implants after prosthodontic loading
title_full Peri-implant crevicular fluid levels of cathepsin-K, RANKL, and OPG around standard, short, and mini dental implants after prosthodontic loading
title_fullStr Peri-implant crevicular fluid levels of cathepsin-K, RANKL, and OPG around standard, short, and mini dental implants after prosthodontic loading
title_full_unstemmed Peri-implant crevicular fluid levels of cathepsin-K, RANKL, and OPG around standard, short, and mini dental implants after prosthodontic loading
title_short Peri-implant crevicular fluid levels of cathepsin-K, RANKL, and OPG around standard, short, and mini dental implants after prosthodontic loading
title_sort peri-implant crevicular fluid levels of cathepsin-k, rankl, and opg around standard, short, and mini dental implants after prosthodontic loading
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4635438/
https://www.ncbi.nlm.nih.gov/pubmed/26550525
http://dx.doi.org/10.5051/jpis.2015.45.5.169
work_keys_str_mv AT alanraif periimplantcrevicularfluidlevelsofcathepsinkranklandopgaroundstandardshortandminidentalimplantsafterprosthodonticloading
AT marakogluismail periimplantcrevicularfluidlevelsofcathepsinkranklandopgaroundstandardshortandminidentalimplantsafterprosthodonticloading
AT halilogluseyfullah periimplantcrevicularfluidlevelsofcathepsinkranklandopgaroundstandardshortandminidentalimplantsafterprosthodonticloading