Comparison Between Digital and Manual Marking for Toric Intraocular Lenses: A Randomized Trial

To compare the clinical outcome of digital and manual marking for toric intraocular lens (IOL) alignment. This is a prospective clinical study that included 60 eyes of 60 patients undergoing cataract surgery with coexisting corneal astigmatism more than 1 diopter (D). The eyes were randomly assigned...

Descripción completa

Detalles Bibliográficos
Autores principales: Elhofi, Abdel Hamid, Helaly, Hany Ahmed
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4635770/
https://www.ncbi.nlm.nih.gov/pubmed/26402830
http://dx.doi.org/10.1097/MD.0000000000001618
_version_ 1782399552202997760
author Elhofi, Abdel Hamid
Helaly, Hany Ahmed
author_facet Elhofi, Abdel Hamid
Helaly, Hany Ahmed
author_sort Elhofi, Abdel Hamid
collection PubMed
description To compare the clinical outcome of digital and manual marking for toric intraocular lens (IOL) alignment. This is a prospective clinical study that included 60 eyes of 60 patients undergoing cataract surgery with coexisting corneal astigmatism more than 1 diopter (D). The eyes were randomly assigned to either digital image guidance using VERION digital marker (Alcon Laboratories, Ft. Worth, TX) or manual slitlamp-assisted preoperative marking using pendulum-attached marker. Tecnis toric IOL (Abbott Medical Optics, Inc, Santa Ana, CA) was implanted in all cases. The mean postoperative uncorrected distance visual acuity (UCDVA) for the digital-marking group was 0.12 + 0.12 logMAR, and for the manual-marking group was 0.18 + 0.14 logMAR (P = 0.104). The mean deviation from targeted induced astigmatism (TIA) for the first group was 0.10 + 0.08 D and for the second group was 0.20 + 0.14 D (P = 0.001). The mean postoperative toric IOL misalignment measured by the slitlamp was 2.4° + 1.96° for the first group and was 4.33° + 2.72° for the second group (P = 0.003). Accurate alignment of the toric IOL is important to achieve the desired astigmatism correction. VERION system has the advantage of preoperative planning and intraoperative digital guidance of the toric IOL alignment. The use of VERION system resulted in less postoperative deviation from TIA and showed less postoperative toric IOL misalignment than using manual-marking technique.
format Online
Article
Text
id pubmed-4635770
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-46357702015-11-30 Comparison Between Digital and Manual Marking for Toric Intraocular Lenses: A Randomized Trial Elhofi, Abdel Hamid Helaly, Hany Ahmed Medicine (Baltimore) 5800 To compare the clinical outcome of digital and manual marking for toric intraocular lens (IOL) alignment. This is a prospective clinical study that included 60 eyes of 60 patients undergoing cataract surgery with coexisting corneal astigmatism more than 1 diopter (D). The eyes were randomly assigned to either digital image guidance using VERION digital marker (Alcon Laboratories, Ft. Worth, TX) or manual slitlamp-assisted preoperative marking using pendulum-attached marker. Tecnis toric IOL (Abbott Medical Optics, Inc, Santa Ana, CA) was implanted in all cases. The mean postoperative uncorrected distance visual acuity (UCDVA) for the digital-marking group was 0.12 + 0.12 logMAR, and for the manual-marking group was 0.18 + 0.14 logMAR (P = 0.104). The mean deviation from targeted induced astigmatism (TIA) for the first group was 0.10 + 0.08 D and for the second group was 0.20 + 0.14 D (P = 0.001). The mean postoperative toric IOL misalignment measured by the slitlamp was 2.4° + 1.96° for the first group and was 4.33° + 2.72° for the second group (P = 0.003). Accurate alignment of the toric IOL is important to achieve the desired astigmatism correction. VERION system has the advantage of preoperative planning and intraoperative digital guidance of the toric IOL alignment. The use of VERION system resulted in less postoperative deviation from TIA and showed less postoperative toric IOL misalignment than using manual-marking technique. Wolters Kluwer Health 2015-09-25 /pmc/articles/PMC4635770/ /pubmed/26402830 http://dx.doi.org/10.1097/MD.0000000000001618 Text en Copyright © 2015 Wolters Kluwer Health, Inc. All rights reserved. http://creativecommons.org/licenses/by-nd/4.0 This is an open access article distributed under the Creative Commons Attribution-NoDerivatives License 4.0, which allows for redistribution, commercial and non-commercial, as long as it is passed along unchanged and in whole, with credit to the author. http://creativecommons.org/licenses/by-nd/4.0
spellingShingle 5800
Elhofi, Abdel Hamid
Helaly, Hany Ahmed
Comparison Between Digital and Manual Marking for Toric Intraocular Lenses: A Randomized Trial
title Comparison Between Digital and Manual Marking for Toric Intraocular Lenses: A Randomized Trial
title_full Comparison Between Digital and Manual Marking for Toric Intraocular Lenses: A Randomized Trial
title_fullStr Comparison Between Digital and Manual Marking for Toric Intraocular Lenses: A Randomized Trial
title_full_unstemmed Comparison Between Digital and Manual Marking for Toric Intraocular Lenses: A Randomized Trial
title_short Comparison Between Digital and Manual Marking for Toric Intraocular Lenses: A Randomized Trial
title_sort comparison between digital and manual marking for toric intraocular lenses: a randomized trial
topic 5800
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4635770/
https://www.ncbi.nlm.nih.gov/pubmed/26402830
http://dx.doi.org/10.1097/MD.0000000000001618
work_keys_str_mv AT elhofiabdelhamid comparisonbetweendigitalandmanualmarkingfortoricintraocularlensesarandomizedtrial
AT helalyhanyahmed comparisonbetweendigitalandmanualmarkingfortoricintraocularlensesarandomizedtrial