Cargando…
Extra-pericardial tamponade following Wolf Mini-Maze procedure: a case report
BACKGROUND: Extra-pericardial tamponade is a rare life threatening condition that has not previously been reported in association with Wolf Mini-Maze procedures. In this case, atypical presentation of cardiac tamponade caused by postoperative anticoagulation resulted in a second hospitalization, a s...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4635985/ https://www.ncbi.nlm.nih.gov/pubmed/26541412 http://dx.doi.org/10.1186/s13019-015-0364-0 |
_version_ | 1782399585103118336 |
---|---|
author | Bailey, James P. |
author_facet | Bailey, James P. |
author_sort | Bailey, James P. |
collection | PubMed |
description | BACKGROUND: Extra-pericardial tamponade is a rare life threatening condition that has not previously been reported in association with Wolf Mini-Maze procedures. In this case, atypical presentation of cardiac tamponade caused by postoperative anticoagulation resulted in a second hospitalization, a second surgery, and delayed recovery time. The goal of this case report is to increase awareness about a life threatening complication that can occur following minimally invasive cardiac surgery. CASE PRESENTATION: A 60 year old male with long standing essential hypertension, who was recently treated for atrial fibrillation utilizing the Wolf Mini-Maze procedure, experienced a postoperative international normalized ratio increase from 3.6 to 5.3 over the course of six days. Fifteen days postoperatively, the patient experienced mild exercise intolerance, his condition rapidly progressed to a constellation of symptoms including severe exercise intolerance, dyspnea, hypotension, and near syncope. A diagnosis of cardiac tamponade was made, and the patient was re-admitted to the hospital. Attempts to reverse his warfarin anticoagulation with fresh frozen plasma and vitamin K were unsuccessful after 24 h. Video-assisted thoracotomy was performed to relieve the tamponade, and during surgery he was diagnosed with extra-pericardial tamponade caused by an extensive hematoma. Complications due to anticoagulation therapy required this re-admission, additional surgery, and delayed recovery. The patient has since recovered completely with no long term morbidities and is asymptomatic three years following initial presentation. CONCLUSIONS: This case marks the first time extra-pericardial tamponade has been reported post cardiothoracic intervention in English literature. Many surgical procedures require postoperative anticoagulation; in the past, warfarin has been the standard of care due to its purported reversibility. This case provides an example of the challenge presented when anticoagulating with warfarin, and the reversal of this anticoagulation. |
format | Online Article Text |
id | pubmed-4635985 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-46359852015-11-07 Extra-pericardial tamponade following Wolf Mini-Maze procedure: a case report Bailey, James P. J Cardiothorac Surg Case Report BACKGROUND: Extra-pericardial tamponade is a rare life threatening condition that has not previously been reported in association with Wolf Mini-Maze procedures. In this case, atypical presentation of cardiac tamponade caused by postoperative anticoagulation resulted in a second hospitalization, a second surgery, and delayed recovery time. The goal of this case report is to increase awareness about a life threatening complication that can occur following minimally invasive cardiac surgery. CASE PRESENTATION: A 60 year old male with long standing essential hypertension, who was recently treated for atrial fibrillation utilizing the Wolf Mini-Maze procedure, experienced a postoperative international normalized ratio increase from 3.6 to 5.3 over the course of six days. Fifteen days postoperatively, the patient experienced mild exercise intolerance, his condition rapidly progressed to a constellation of symptoms including severe exercise intolerance, dyspnea, hypotension, and near syncope. A diagnosis of cardiac tamponade was made, and the patient was re-admitted to the hospital. Attempts to reverse his warfarin anticoagulation with fresh frozen plasma and vitamin K were unsuccessful after 24 h. Video-assisted thoracotomy was performed to relieve the tamponade, and during surgery he was diagnosed with extra-pericardial tamponade caused by an extensive hematoma. Complications due to anticoagulation therapy required this re-admission, additional surgery, and delayed recovery. The patient has since recovered completely with no long term morbidities and is asymptomatic three years following initial presentation. CONCLUSIONS: This case marks the first time extra-pericardial tamponade has been reported post cardiothoracic intervention in English literature. Many surgical procedures require postoperative anticoagulation; in the past, warfarin has been the standard of care due to its purported reversibility. This case provides an example of the challenge presented when anticoagulating with warfarin, and the reversal of this anticoagulation. BioMed Central 2015-11-05 /pmc/articles/PMC4635985/ /pubmed/26541412 http://dx.doi.org/10.1186/s13019-015-0364-0 Text en © Bailey. 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Case Report Bailey, James P. Extra-pericardial tamponade following Wolf Mini-Maze procedure: a case report |
title | Extra-pericardial tamponade following Wolf Mini-Maze procedure: a case report |
title_full | Extra-pericardial tamponade following Wolf Mini-Maze procedure: a case report |
title_fullStr | Extra-pericardial tamponade following Wolf Mini-Maze procedure: a case report |
title_full_unstemmed | Extra-pericardial tamponade following Wolf Mini-Maze procedure: a case report |
title_short | Extra-pericardial tamponade following Wolf Mini-Maze procedure: a case report |
title_sort | extra-pericardial tamponade following wolf mini-maze procedure: a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4635985/ https://www.ncbi.nlm.nih.gov/pubmed/26541412 http://dx.doi.org/10.1186/s13019-015-0364-0 |
work_keys_str_mv | AT baileyjamesp extrapericardialtamponadefollowingwolfminimazeprocedureacasereport |