Cargando…
Assessment of Gate Width Size on Lifetime-Based Förster Resonance Energy Transfer Parameter Estimation
Förster Resonance Energy Transfer (FRET) enables the observation of interactions at the nanoscale level through the use of fluorescence optical imaging techniques. In FRET, fluorescence lifetime imaging can be used to quantify the fluorescence lifetime changes of the donor molecule, which are associ...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4636205/ https://www.ncbi.nlm.nih.gov/pubmed/26557647 http://dx.doi.org/10.3390/photonics2041027 |
_version_ | 1782399615996264448 |
---|---|
author | Chen, Sez-Jade Sinsuebphon, Nattawut Intes, Xavier |
author_facet | Chen, Sez-Jade Sinsuebphon, Nattawut Intes, Xavier |
author_sort | Chen, Sez-Jade |
collection | PubMed |
description | Förster Resonance Energy Transfer (FRET) enables the observation of interactions at the nanoscale level through the use of fluorescence optical imaging techniques. In FRET, fluorescence lifetime imaging can be used to quantify the fluorescence lifetime changes of the donor molecule, which are associated with proximity between acceptor and donor molecules. Among the FRET parameters derived from fluorescence lifetime imaging, the percentage of donor that interacts with the acceptor (in proximity) can be estimated via model-based fitting. However, estimation of the lifetime parameters can be affected by the acquisition parameters such as the temporal characteristics of the imaging system. Herein, we investigate the effect of various gate widths on the accuracy of estimation of FRET parameters with focus on the near-infrared spectral window. Experiments were performed in silico, in vitro, and in vivo with gate width sizes ranging from 300 ps to 1000 ps in intervals of 100 ps. For all cases, the FRET parameters were retrieved accurately and the imaging acquisition time was decreased three-fold. These results indicate that increasing the gate width up to 1000 ps still allows for accurate quantification of FRET interactions even in the case of short lifetimes such as those encountered with near-infrared FRET pairs. |
format | Online Article Text |
id | pubmed-4636205 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
record_format | MEDLINE/PubMed |
spelling | pubmed-46362052015-12-01 Assessment of Gate Width Size on Lifetime-Based Förster Resonance Energy Transfer Parameter Estimation Chen, Sez-Jade Sinsuebphon, Nattawut Intes, Xavier Photonics Article Förster Resonance Energy Transfer (FRET) enables the observation of interactions at the nanoscale level through the use of fluorescence optical imaging techniques. In FRET, fluorescence lifetime imaging can be used to quantify the fluorescence lifetime changes of the donor molecule, which are associated with proximity between acceptor and donor molecules. Among the FRET parameters derived from fluorescence lifetime imaging, the percentage of donor that interacts with the acceptor (in proximity) can be estimated via model-based fitting. However, estimation of the lifetime parameters can be affected by the acquisition parameters such as the temporal characteristics of the imaging system. Herein, we investigate the effect of various gate widths on the accuracy of estimation of FRET parameters with focus on the near-infrared spectral window. Experiments were performed in silico, in vitro, and in vivo with gate width sizes ranging from 300 ps to 1000 ps in intervals of 100 ps. For all cases, the FRET parameters were retrieved accurately and the imaging acquisition time was decreased three-fold. These results indicate that increasing the gate width up to 1000 ps still allows for accurate quantification of FRET interactions even in the case of short lifetimes such as those encountered with near-infrared FRET pairs. 2015-09-28 2015-12 /pmc/articles/PMC4636205/ /pubmed/26557647 http://dx.doi.org/10.3390/photonics2041027 Text en This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Chen, Sez-Jade Sinsuebphon, Nattawut Intes, Xavier Assessment of Gate Width Size on Lifetime-Based Förster Resonance Energy Transfer Parameter Estimation |
title | Assessment of Gate Width Size on Lifetime-Based Förster Resonance Energy Transfer Parameter Estimation |
title_full | Assessment of Gate Width Size on Lifetime-Based Förster Resonance Energy Transfer Parameter Estimation |
title_fullStr | Assessment of Gate Width Size on Lifetime-Based Förster Resonance Energy Transfer Parameter Estimation |
title_full_unstemmed | Assessment of Gate Width Size on Lifetime-Based Förster Resonance Energy Transfer Parameter Estimation |
title_short | Assessment of Gate Width Size on Lifetime-Based Förster Resonance Energy Transfer Parameter Estimation |
title_sort | assessment of gate width size on lifetime-based förster resonance energy transfer parameter estimation |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4636205/ https://www.ncbi.nlm.nih.gov/pubmed/26557647 http://dx.doi.org/10.3390/photonics2041027 |
work_keys_str_mv | AT chensezjade assessmentofgatewidthsizeonlifetimebasedforsterresonanceenergytransferparameterestimation AT sinsuebphonnattawut assessmentofgatewidthsizeonlifetimebasedforsterresonanceenergytransferparameterestimation AT intesxavier assessmentofgatewidthsizeonlifetimebasedforsterresonanceenergytransferparameterestimation |