Cargando…

Validation of a HPLC/FLD Method for Quantification of Tocotrienols in Human Plasma

Quantification of tocotrienols in human plasma is critical when the attention towards tocotrienols on its distinctive properties is arising. We aim to develop a simple and practical normal-phase high performance liquid chromatography method to quantify the amount of four tocotrienol homologues in hu...

Descripción completa

Detalles Bibliográficos
Autores principales: Che, Hui-Ling, Tan, Doryn Meam-Yee, Meganathan, Puvaneswari, Gan, Yee-Lin, Abdul Razak, Ghazali, Fu, Ju-Yen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4641197/
https://www.ncbi.nlm.nih.gov/pubmed/26604927
http://dx.doi.org/10.1155/2015/357609
_version_ 1782400157467279360
author Che, Hui-Ling
Tan, Doryn Meam-Yee
Meganathan, Puvaneswari
Gan, Yee-Lin
Abdul Razak, Ghazali
Fu, Ju-Yen
author_facet Che, Hui-Ling
Tan, Doryn Meam-Yee
Meganathan, Puvaneswari
Gan, Yee-Lin
Abdul Razak, Ghazali
Fu, Ju-Yen
author_sort Che, Hui-Ling
collection PubMed
description Quantification of tocotrienols in human plasma is critical when the attention towards tocotrienols on its distinctive properties is arising. We aim to develop a simple and practical normal-phase high performance liquid chromatography method to quantify the amount of four tocotrienol homologues in human plasma. Using both the external and internal standards, tocotrienol homologues were quantified via a normal-phase high performance liquid chromatography with fluorescence detector maintained at the excitation wavelength of 295 nm and the emission wavelength of 325 nm. The four tocotrienol homologues were well separated within 30 minutes. A large interindividual variation between subjects was observed as the absorption of tocotrienols is dependent on food matrix and gut lipolysis. The accuracies of lower and upper limit of quantification ranged between 92% and 109% for intraday assays and 90% and 112% for interday assays. This method was successfully applied to quantify the total amount of four tocotrienol homologues in human plasma.
format Online
Article
Text
id pubmed-4641197
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-46411972015-11-24 Validation of a HPLC/FLD Method for Quantification of Tocotrienols in Human Plasma Che, Hui-Ling Tan, Doryn Meam-Yee Meganathan, Puvaneswari Gan, Yee-Lin Abdul Razak, Ghazali Fu, Ju-Yen Int J Anal Chem Research Article Quantification of tocotrienols in human plasma is critical when the attention towards tocotrienols on its distinctive properties is arising. We aim to develop a simple and practical normal-phase high performance liquid chromatography method to quantify the amount of four tocotrienol homologues in human plasma. Using both the external and internal standards, tocotrienol homologues were quantified via a normal-phase high performance liquid chromatography with fluorescence detector maintained at the excitation wavelength of 295 nm and the emission wavelength of 325 nm. The four tocotrienol homologues were well separated within 30 minutes. A large interindividual variation between subjects was observed as the absorption of tocotrienols is dependent on food matrix and gut lipolysis. The accuracies of lower and upper limit of quantification ranged between 92% and 109% for intraday assays and 90% and 112% for interday assays. This method was successfully applied to quantify the total amount of four tocotrienol homologues in human plasma. Hindawi Publishing Corporation 2015 2015-10-28 /pmc/articles/PMC4641197/ /pubmed/26604927 http://dx.doi.org/10.1155/2015/357609 Text en Copyright © 2015 Hui-Ling Che et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Che, Hui-Ling
Tan, Doryn Meam-Yee
Meganathan, Puvaneswari
Gan, Yee-Lin
Abdul Razak, Ghazali
Fu, Ju-Yen
Validation of a HPLC/FLD Method for Quantification of Tocotrienols in Human Plasma
title Validation of a HPLC/FLD Method for Quantification of Tocotrienols in Human Plasma
title_full Validation of a HPLC/FLD Method for Quantification of Tocotrienols in Human Plasma
title_fullStr Validation of a HPLC/FLD Method for Quantification of Tocotrienols in Human Plasma
title_full_unstemmed Validation of a HPLC/FLD Method for Quantification of Tocotrienols in Human Plasma
title_short Validation of a HPLC/FLD Method for Quantification of Tocotrienols in Human Plasma
title_sort validation of a hplc/fld method for quantification of tocotrienols in human plasma
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4641197/
https://www.ncbi.nlm.nih.gov/pubmed/26604927
http://dx.doi.org/10.1155/2015/357609
work_keys_str_mv AT chehuiling validationofahplcfldmethodforquantificationoftocotrienolsinhumanplasma
AT tandorynmeamyee validationofahplcfldmethodforquantificationoftocotrienolsinhumanplasma
AT meganathanpuvaneswari validationofahplcfldmethodforquantificationoftocotrienolsinhumanplasma
AT ganyeelin validationofahplcfldmethodforquantificationoftocotrienolsinhumanplasma
AT abdulrazakghazali validationofahplcfldmethodforquantificationoftocotrienolsinhumanplasma
AT fujuyen validationofahplcfldmethodforquantificationoftocotrienolsinhumanplasma