Cargando…

Stability-Indicating HPLC Assay for Determination of Idebenone in Pharmaceutical Forms

A stability-indicating method was validated for the determination in pharmaceutical forms of idebenone a coenzyme Q10-like compound. The assay was achieved by liquid chromatography analysis using a reversed-phase C18 column and a detector set at 480 nm. The optimized mobile phase consisted of isocra...

Descripción completa

Detalles Bibliográficos
Autores principales: Kombath, Sonoube, Balde, Issa-Bella, Carret, Sandra, Kabiche, Sofiane, Cisternino, Salvatore, Fontan, Jean-Eudes, Schlatter, Joël
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4641926/
https://www.ncbi.nlm.nih.gov/pubmed/26605105
http://dx.doi.org/10.1155/2015/835986
_version_ 1782400266810687488
author Kombath, Sonoube
Balde, Issa-Bella
Carret, Sandra
Kabiche, Sofiane
Cisternino, Salvatore
Fontan, Jean-Eudes
Schlatter, Joël
author_facet Kombath, Sonoube
Balde, Issa-Bella
Carret, Sandra
Kabiche, Sofiane
Cisternino, Salvatore
Fontan, Jean-Eudes
Schlatter, Joël
author_sort Kombath, Sonoube
collection PubMed
description A stability-indicating method was validated for the determination in pharmaceutical forms of idebenone a coenzyme Q10-like compound. The assay was achieved by liquid chromatography analysis using a reversed-phase C18 column and a detector set at 480 nm. The optimized mobile phase consisted of isocratic flow rate at 1.0 mL/min for 3 min with methanol. The linearity of the assay was demonstrated in the range of 3.0 to 8.0 mg/mL with a correlation coefficient r (2) > 0.998. The limits of detection and quantification were 0.03 and 0.05 mg/mL, respectively. The intraday and interday precisions were less than 1.0%. Accuracy of the method ranged from 98.6 to 101.5% with RSD < 0.6%. Specificity of the assay showed no interference from tablets components and breakdown products formed by alkaline, acidic, oxidative, sunlight, and high temperature conditions. This method allows accurate and reliable determination of idebenone for drug stability assay in pharmaceutical studies.
format Online
Article
Text
id pubmed-4641926
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-46419262015-11-24 Stability-Indicating HPLC Assay for Determination of Idebenone in Pharmaceutical Forms Kombath, Sonoube Balde, Issa-Bella Carret, Sandra Kabiche, Sofiane Cisternino, Salvatore Fontan, Jean-Eudes Schlatter, Joël J Anal Methods Chem Research Article A stability-indicating method was validated for the determination in pharmaceutical forms of idebenone a coenzyme Q10-like compound. The assay was achieved by liquid chromatography analysis using a reversed-phase C18 column and a detector set at 480 nm. The optimized mobile phase consisted of isocratic flow rate at 1.0 mL/min for 3 min with methanol. The linearity of the assay was demonstrated in the range of 3.0 to 8.0 mg/mL with a correlation coefficient r (2) > 0.998. The limits of detection and quantification were 0.03 and 0.05 mg/mL, respectively. The intraday and interday precisions were less than 1.0%. Accuracy of the method ranged from 98.6 to 101.5% with RSD < 0.6%. Specificity of the assay showed no interference from tablets components and breakdown products formed by alkaline, acidic, oxidative, sunlight, and high temperature conditions. This method allows accurate and reliable determination of idebenone for drug stability assay in pharmaceutical studies. Hindawi Publishing Corporation 2015 2015-10-29 /pmc/articles/PMC4641926/ /pubmed/26605105 http://dx.doi.org/10.1155/2015/835986 Text en Copyright © 2015 Sonoube Kombath et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Kombath, Sonoube
Balde, Issa-Bella
Carret, Sandra
Kabiche, Sofiane
Cisternino, Salvatore
Fontan, Jean-Eudes
Schlatter, Joël
Stability-Indicating HPLC Assay for Determination of Idebenone in Pharmaceutical Forms
title Stability-Indicating HPLC Assay for Determination of Idebenone in Pharmaceutical Forms
title_full Stability-Indicating HPLC Assay for Determination of Idebenone in Pharmaceutical Forms
title_fullStr Stability-Indicating HPLC Assay for Determination of Idebenone in Pharmaceutical Forms
title_full_unstemmed Stability-Indicating HPLC Assay for Determination of Idebenone in Pharmaceutical Forms
title_short Stability-Indicating HPLC Assay for Determination of Idebenone in Pharmaceutical Forms
title_sort stability-indicating hplc assay for determination of idebenone in pharmaceutical forms
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4641926/
https://www.ncbi.nlm.nih.gov/pubmed/26605105
http://dx.doi.org/10.1155/2015/835986
work_keys_str_mv AT kombathsonoube stabilityindicatinghplcassayfordeterminationofidebenoneinpharmaceuticalforms
AT baldeissabella stabilityindicatinghplcassayfordeterminationofidebenoneinpharmaceuticalforms
AT carretsandra stabilityindicatinghplcassayfordeterminationofidebenoneinpharmaceuticalforms
AT kabichesofiane stabilityindicatinghplcassayfordeterminationofidebenoneinpharmaceuticalforms
AT cisterninosalvatore stabilityindicatinghplcassayfordeterminationofidebenoneinpharmaceuticalforms
AT fontanjeaneudes stabilityindicatinghplcassayfordeterminationofidebenoneinpharmaceuticalforms
AT schlatterjoel stabilityindicatinghplcassayfordeterminationofidebenoneinpharmaceuticalforms