Cargando…
Subtraction MR Venography Acquired from Time-Resolved Contrast-Enhanced MR Angiography: Comparison with Phase-Contrast MR Venography and Single-Phase Contrast-Enhanced MR Venography
OBJECTIVE: To evaluate the image characteristics of subtraction magnetic resonance venography (SMRV) from time-resolved contrast-enhanced MR angiography (TRMRA) compared with phase-contrast MR venography (PCMRV) and single-phase contrast-enhanced MR venography (CEMRV). MATERIALS AND METHODS: Twenty-...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Radiology
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4644759/ https://www.ncbi.nlm.nih.gov/pubmed/26576127 http://dx.doi.org/10.3348/kjr.2015.16.6.1353 |
_version_ | 1782400699350384640 |
---|---|
author | Jang, Jinhee Kim, Bum-Soo Sung, Jinkyeong Kim, Bom-Yi Choi, Hyun Seok Jung, So-Lyung Ahn, Kook-Jin |
author_facet | Jang, Jinhee Kim, Bum-Soo Sung, Jinkyeong Kim, Bom-Yi Choi, Hyun Seok Jung, So-Lyung Ahn, Kook-Jin |
author_sort | Jang, Jinhee |
collection | PubMed |
description | OBJECTIVE: To evaluate the image characteristics of subtraction magnetic resonance venography (SMRV) from time-resolved contrast-enhanced MR angiography (TRMRA) compared with phase-contrast MR venography (PCMRV) and single-phase contrast-enhanced MR venography (CEMRV). MATERIALS AND METHODS: Twenty-one patients who underwent brain MR venography (MRV) using standard protocols (PCMRV, CEMRV, and TRMRA) were included. SMRV was made by subtracting the arterial phase data from the venous phase data in TRMRA. Co-registration and subtraction of the two volume data was done using commercially available software. Image quality and the degree of arterial contamination of the three MRVs were compared. In the three MRVs, 19 pre-defined venous structures (14 dural sinuses and 5 cerebral veins) were evaluated. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the three MRVs were also compared. RESULTS: Single-phase contrast-enhanced MR venography showed better image quality (median score 4 in both reviewers) than did the other two MRVs (p < 0.001), whereas SMRV (median score 3 in both reviewers) and PCMRV (median score 3 in both reviewers) had similar image quality (p ≥ 0.951). SMRV (median score 0 in both reviewers) suppressed arterial signal better than did the other MRVs (median score 1 in CEMRV, median score 2 in PCMRV, both reviewers) (p < 0.001). The dural sinus score of SMRV (median and interquartile range [IQR] 48, 43-50 for reviewer 1, 47, 43-49 for reviewer 2) was significantly higher than for PCMRV (median and IQR 31, 25-34 for reviewer 1, 30, 23-32 for reviewer 2) (p < 0.01) and did not differ from that of CEMRV (median and IQR 50, 47-52 for reviewer 1, 49, 45-51 for reviewer 2) (p = 0.146 in reviewer 1 and 0.123 in reviewer 2). The SNR and CNR of SMRV (median and IQR 104.5, 83.1-121.2 and 104.1, 74.9-120.5, respectively) were between those of CEMRV (median and IQR 150.3, 111-182.6 and 148.4, 108-178.2) and PCMRV (median and IQR 59.4, 49.2-74.9 and 53.6, 43.8-69.2). CONCLUSION: Subtraction magnetic resonance venography is a promising MRV method, with acceptable image quality and good arterial suppression. |
format | Online Article Text |
id | pubmed-4644759 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | The Korean Society of Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-46447592015-11-16 Subtraction MR Venography Acquired from Time-Resolved Contrast-Enhanced MR Angiography: Comparison with Phase-Contrast MR Venography and Single-Phase Contrast-Enhanced MR Venography Jang, Jinhee Kim, Bum-Soo Sung, Jinkyeong Kim, Bom-Yi Choi, Hyun Seok Jung, So-Lyung Ahn, Kook-Jin Korean J Radiol Neurointervention OBJECTIVE: To evaluate the image characteristics of subtraction magnetic resonance venography (SMRV) from time-resolved contrast-enhanced MR angiography (TRMRA) compared with phase-contrast MR venography (PCMRV) and single-phase contrast-enhanced MR venography (CEMRV). MATERIALS AND METHODS: Twenty-one patients who underwent brain MR venography (MRV) using standard protocols (PCMRV, CEMRV, and TRMRA) were included. SMRV was made by subtracting the arterial phase data from the venous phase data in TRMRA. Co-registration and subtraction of the two volume data was done using commercially available software. Image quality and the degree of arterial contamination of the three MRVs were compared. In the three MRVs, 19 pre-defined venous structures (14 dural sinuses and 5 cerebral veins) were evaluated. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the three MRVs were also compared. RESULTS: Single-phase contrast-enhanced MR venography showed better image quality (median score 4 in both reviewers) than did the other two MRVs (p < 0.001), whereas SMRV (median score 3 in both reviewers) and PCMRV (median score 3 in both reviewers) had similar image quality (p ≥ 0.951). SMRV (median score 0 in both reviewers) suppressed arterial signal better than did the other MRVs (median score 1 in CEMRV, median score 2 in PCMRV, both reviewers) (p < 0.001). The dural sinus score of SMRV (median and interquartile range [IQR] 48, 43-50 for reviewer 1, 47, 43-49 for reviewer 2) was significantly higher than for PCMRV (median and IQR 31, 25-34 for reviewer 1, 30, 23-32 for reviewer 2) (p < 0.01) and did not differ from that of CEMRV (median and IQR 50, 47-52 for reviewer 1, 49, 45-51 for reviewer 2) (p = 0.146 in reviewer 1 and 0.123 in reviewer 2). The SNR and CNR of SMRV (median and IQR 104.5, 83.1-121.2 and 104.1, 74.9-120.5, respectively) were between those of CEMRV (median and IQR 150.3, 111-182.6 and 148.4, 108-178.2) and PCMRV (median and IQR 59.4, 49.2-74.9 and 53.6, 43.8-69.2). CONCLUSION: Subtraction magnetic resonance venography is a promising MRV method, with acceptable image quality and good arterial suppression. The Korean Society of Radiology 2015 2015-10-26 /pmc/articles/PMC4644759/ /pubmed/26576127 http://dx.doi.org/10.3348/kjr.2015.16.6.1353 Text en Copyright © 2015 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Neurointervention Jang, Jinhee Kim, Bum-Soo Sung, Jinkyeong Kim, Bom-Yi Choi, Hyun Seok Jung, So-Lyung Ahn, Kook-Jin Subtraction MR Venography Acquired from Time-Resolved Contrast-Enhanced MR Angiography: Comparison with Phase-Contrast MR Venography and Single-Phase Contrast-Enhanced MR Venography |
title | Subtraction MR Venography Acquired from Time-Resolved Contrast-Enhanced MR Angiography: Comparison with Phase-Contrast MR Venography and Single-Phase Contrast-Enhanced MR Venography |
title_full | Subtraction MR Venography Acquired from Time-Resolved Contrast-Enhanced MR Angiography: Comparison with Phase-Contrast MR Venography and Single-Phase Contrast-Enhanced MR Venography |
title_fullStr | Subtraction MR Venography Acquired from Time-Resolved Contrast-Enhanced MR Angiography: Comparison with Phase-Contrast MR Venography and Single-Phase Contrast-Enhanced MR Venography |
title_full_unstemmed | Subtraction MR Venography Acquired from Time-Resolved Contrast-Enhanced MR Angiography: Comparison with Phase-Contrast MR Venography and Single-Phase Contrast-Enhanced MR Venography |
title_short | Subtraction MR Venography Acquired from Time-Resolved Contrast-Enhanced MR Angiography: Comparison with Phase-Contrast MR Venography and Single-Phase Contrast-Enhanced MR Venography |
title_sort | subtraction mr venography acquired from time-resolved contrast-enhanced mr angiography: comparison with phase-contrast mr venography and single-phase contrast-enhanced mr venography |
topic | Neurointervention |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4644759/ https://www.ncbi.nlm.nih.gov/pubmed/26576127 http://dx.doi.org/10.3348/kjr.2015.16.6.1353 |
work_keys_str_mv | AT jangjinhee subtractionmrvenographyacquiredfromtimeresolvedcontrastenhancedmrangiographycomparisonwithphasecontrastmrvenographyandsinglephasecontrastenhancedmrvenography AT kimbumsoo subtractionmrvenographyacquiredfromtimeresolvedcontrastenhancedmrangiographycomparisonwithphasecontrastmrvenographyandsinglephasecontrastenhancedmrvenography AT sungjinkyeong subtractionmrvenographyacquiredfromtimeresolvedcontrastenhancedmrangiographycomparisonwithphasecontrastmrvenographyandsinglephasecontrastenhancedmrvenography AT kimbomyi subtractionmrvenographyacquiredfromtimeresolvedcontrastenhancedmrangiographycomparisonwithphasecontrastmrvenographyandsinglephasecontrastenhancedmrvenography AT choihyunseok subtractionmrvenographyacquiredfromtimeresolvedcontrastenhancedmrangiographycomparisonwithphasecontrastmrvenographyandsinglephasecontrastenhancedmrvenography AT jungsolyung subtractionmrvenographyacquiredfromtimeresolvedcontrastenhancedmrangiographycomparisonwithphasecontrastmrvenographyandsinglephasecontrastenhancedmrvenography AT ahnkookjin subtractionmrvenographyacquiredfromtimeresolvedcontrastenhancedmrangiographycomparisonwithphasecontrastmrvenographyandsinglephasecontrastenhancedmrvenography |