Cargando…

Influence of clearance on the time-dependent performance of the hip following hemiarthroplasty: A finite element study with biphasic acetabular cartilage properties

Hip hemiarthroplasty is a common treatment for femoral neck fracture. However, the acetabular cartilage may degenerate after hemiarthroplasty leading to postoperative failure and the need for revision surgery. The clearance between the acetabular cartilage and head of the prosthesis is one of the po...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Junyan, Hua, Xijin, Jin, Zhongmin, Fisher, John, Wilcox, Ruth K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Butterworth-Heinemann 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4644988/
https://www.ncbi.nlm.nih.gov/pubmed/24957488
http://dx.doi.org/10.1016/j.medengphy.2014.05.014
_version_ 1782400736539181056
author Li, Junyan
Hua, Xijin
Jin, Zhongmin
Fisher, John
Wilcox, Ruth K.
author_facet Li, Junyan
Hua, Xijin
Jin, Zhongmin
Fisher, John
Wilcox, Ruth K.
author_sort Li, Junyan
collection PubMed
description Hip hemiarthroplasty is a common treatment for femoral neck fracture. However, the acetabular cartilage may degenerate after hemiarthroplasty leading to postoperative failure and the need for revision surgery. The clearance between the acetabular cartilage and head of the prosthesis is one of the potential reasons for this failure. In this study, the influence of joint clearance on the biomechanical function of a generic hip model in hemiarthroplasty was investigated using biphasic numerical simulation. Both a prolonged loading period of 4000 s and dynamic gait load of 10 cycles were considered. It was found that a larger clearance led to a higher stress level, a faster reduction in load supported by the fluid and a faster cartilage consolidation process. Additionally, the mechanical performance of the acetabular cartilage in the natural model was similar to that in the hemiarthroplasty model with no clearance but different from the hemiarthroplasty models with clearances of 0.5 mm and larger. The results demonstrated that a larger clearance in hip hemiarthroplasty is more harmful to the acetabular cartilage and prosthesis heads with more available dimensions (i.e. smaller increments in diameter) could be manufactured for surgeons to achieve a lower clearance, and reduced contact stress in hemiarthroplasty surgeries.
format Online
Article
Text
id pubmed-4644988
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Butterworth-Heinemann
record_format MEDLINE/PubMed
spelling pubmed-46449882015-12-08 Influence of clearance on the time-dependent performance of the hip following hemiarthroplasty: A finite element study with biphasic acetabular cartilage properties Li, Junyan Hua, Xijin Jin, Zhongmin Fisher, John Wilcox, Ruth K. Med Eng Phys Article Hip hemiarthroplasty is a common treatment for femoral neck fracture. However, the acetabular cartilage may degenerate after hemiarthroplasty leading to postoperative failure and the need for revision surgery. The clearance between the acetabular cartilage and head of the prosthesis is one of the potential reasons for this failure. In this study, the influence of joint clearance on the biomechanical function of a generic hip model in hemiarthroplasty was investigated using biphasic numerical simulation. Both a prolonged loading period of 4000 s and dynamic gait load of 10 cycles were considered. It was found that a larger clearance led to a higher stress level, a faster reduction in load supported by the fluid and a faster cartilage consolidation process. Additionally, the mechanical performance of the acetabular cartilage in the natural model was similar to that in the hemiarthroplasty model with no clearance but different from the hemiarthroplasty models with clearances of 0.5 mm and larger. The results demonstrated that a larger clearance in hip hemiarthroplasty is more harmful to the acetabular cartilage and prosthesis heads with more available dimensions (i.e. smaller increments in diameter) could be manufactured for surgeons to achieve a lower clearance, and reduced contact stress in hemiarthroplasty surgeries. Butterworth-Heinemann 2014-11 /pmc/articles/PMC4644988/ /pubmed/24957488 http://dx.doi.org/10.1016/j.medengphy.2014.05.014 Text en © 2014 The Authors http://creativecommons.org/licenses/by/3.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Li, Junyan
Hua, Xijin
Jin, Zhongmin
Fisher, John
Wilcox, Ruth K.
Influence of clearance on the time-dependent performance of the hip following hemiarthroplasty: A finite element study with biphasic acetabular cartilage properties
title Influence of clearance on the time-dependent performance of the hip following hemiarthroplasty: A finite element study with biphasic acetabular cartilage properties
title_full Influence of clearance on the time-dependent performance of the hip following hemiarthroplasty: A finite element study with biphasic acetabular cartilage properties
title_fullStr Influence of clearance on the time-dependent performance of the hip following hemiarthroplasty: A finite element study with biphasic acetabular cartilage properties
title_full_unstemmed Influence of clearance on the time-dependent performance of the hip following hemiarthroplasty: A finite element study with biphasic acetabular cartilage properties
title_short Influence of clearance on the time-dependent performance of the hip following hemiarthroplasty: A finite element study with biphasic acetabular cartilage properties
title_sort influence of clearance on the time-dependent performance of the hip following hemiarthroplasty: a finite element study with biphasic acetabular cartilage properties
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4644988/
https://www.ncbi.nlm.nih.gov/pubmed/24957488
http://dx.doi.org/10.1016/j.medengphy.2014.05.014
work_keys_str_mv AT lijunyan influenceofclearanceonthetimedependentperformanceofthehipfollowinghemiarthroplastyafiniteelementstudywithbiphasicacetabularcartilageproperties
AT huaxijin influenceofclearanceonthetimedependentperformanceofthehipfollowinghemiarthroplastyafiniteelementstudywithbiphasicacetabularcartilageproperties
AT jinzhongmin influenceofclearanceonthetimedependentperformanceofthehipfollowinghemiarthroplastyafiniteelementstudywithbiphasicacetabularcartilageproperties
AT fisherjohn influenceofclearanceonthetimedependentperformanceofthehipfollowinghemiarthroplastyafiniteelementstudywithbiphasicacetabularcartilageproperties
AT wilcoxruthk influenceofclearanceonthetimedependentperformanceofthehipfollowinghemiarthroplastyafiniteelementstudywithbiphasicacetabularcartilageproperties