Cargando…

Comparison of the NIST and PTB Air-Kerma Standards for Low-Energy X-Rays

A comparison has been made of the air-kerma standards for low-energy x rays at the National Institute of Standards and Technology (NIST) and the Physikalisch-Technische Bundesanstalt (PTB). The comparison involved a series of measurements at the PTB and the NIST using the air-kerma standards and two...

Descripción completa

Detalles Bibliográficos
Autores principales: O’Brien, Michelle, Bueermann, Ludwig
Formato: Online Artículo Texto
Lenguaje:English
Publicado: [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4646528/
https://www.ncbi.nlm.nih.gov/pubmed/27504231
http://dx.doi.org/10.6028/jres.114.023
_version_ 1782400950972973056
author O’Brien, Michelle
Bueermann, Ludwig
author_facet O’Brien, Michelle
Bueermann, Ludwig
author_sort O’Brien, Michelle
collection PubMed
description A comparison has been made of the air-kerma standards for low-energy x rays at the National Institute of Standards and Technology (NIST) and the Physikalisch-Technische Bundesanstalt (PTB). The comparison involved a series of measurements at the PTB and the NIST using the air-kerma standards and two NIST reference-class transfer ionization chamber standards. Results are presented for the reference radiation beam qualities in the range from 25 kV to 50 kV for low energy x rays, including the techniques used for mammography dose traceability. The tungsten generated reference radiation qualities, between 25 kV and 50 kV used for this comparison, are new to NIST; therefore this comparison will serve as the preliminary comparison for NIST and a verification of the primary standard correction factors. The mammography comparison will repeat two previously unpublished comparisons between PTB and NIST. The results show the standards to be in reasonable agreement within the standard uncertainty of the comparison of about 0.4 %.
format Online
Article
Text
id pubmed-4646528
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
record_format MEDLINE/PubMed
spelling pubmed-46465282016-08-08 Comparison of the NIST and PTB Air-Kerma Standards for Low-Energy X-Rays O’Brien, Michelle Bueermann, Ludwig J Res Natl Inst Stand Technol Article A comparison has been made of the air-kerma standards for low-energy x rays at the National Institute of Standards and Technology (NIST) and the Physikalisch-Technische Bundesanstalt (PTB). The comparison involved a series of measurements at the PTB and the NIST using the air-kerma standards and two NIST reference-class transfer ionization chamber standards. Results are presented for the reference radiation beam qualities in the range from 25 kV to 50 kV for low energy x rays, including the techniques used for mammography dose traceability. The tungsten generated reference radiation qualities, between 25 kV and 50 kV used for this comparison, are new to NIST; therefore this comparison will serve as the preliminary comparison for NIST and a verification of the primary standard correction factors. The mammography comparison will repeat two previously unpublished comparisons between PTB and NIST. The results show the standards to be in reasonable agreement within the standard uncertainty of the comparison of about 0.4 %. [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 2009 2009-12-01 /pmc/articles/PMC4646528/ /pubmed/27504231 http://dx.doi.org/10.6028/jres.114.023 Text en https://creativecommons.org/publicdomain/zero/1.0/ The Journal of Research of the National Institute of Standards and Technology is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright.
spellingShingle Article
O’Brien, Michelle
Bueermann, Ludwig
Comparison of the NIST and PTB Air-Kerma Standards for Low-Energy X-Rays
title Comparison of the NIST and PTB Air-Kerma Standards for Low-Energy X-Rays
title_full Comparison of the NIST and PTB Air-Kerma Standards for Low-Energy X-Rays
title_fullStr Comparison of the NIST and PTB Air-Kerma Standards for Low-Energy X-Rays
title_full_unstemmed Comparison of the NIST and PTB Air-Kerma Standards for Low-Energy X-Rays
title_short Comparison of the NIST and PTB Air-Kerma Standards for Low-Energy X-Rays
title_sort comparison of the nist and ptb air-kerma standards for low-energy x-rays
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4646528/
https://www.ncbi.nlm.nih.gov/pubmed/27504231
http://dx.doi.org/10.6028/jres.114.023
work_keys_str_mv AT obrienmichelle comparisonofthenistandptbairkermastandardsforlowenergyxrays
AT bueermannludwig comparisonofthenistandptbairkermastandardsforlowenergyxrays