Cargando…
Comparison of the NIST and PTB Air-Kerma Standards for Low-Energy X-Rays
A comparison has been made of the air-kerma standards for low-energy x rays at the National Institute of Standards and Technology (NIST) and the Physikalisch-Technische Bundesanstalt (PTB). The comparison involved a series of measurements at the PTB and the NIST using the air-kerma standards and two...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
[Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4646528/ https://www.ncbi.nlm.nih.gov/pubmed/27504231 http://dx.doi.org/10.6028/jres.114.023 |
_version_ | 1782400950972973056 |
---|---|
author | O’Brien, Michelle Bueermann, Ludwig |
author_facet | O’Brien, Michelle Bueermann, Ludwig |
author_sort | O’Brien, Michelle |
collection | PubMed |
description | A comparison has been made of the air-kerma standards for low-energy x rays at the National Institute of Standards and Technology (NIST) and the Physikalisch-Technische Bundesanstalt (PTB). The comparison involved a series of measurements at the PTB and the NIST using the air-kerma standards and two NIST reference-class transfer ionization chamber standards. Results are presented for the reference radiation beam qualities in the range from 25 kV to 50 kV for low energy x rays, including the techniques used for mammography dose traceability. The tungsten generated reference radiation qualities, between 25 kV and 50 kV used for this comparison, are new to NIST; therefore this comparison will serve as the preliminary comparison for NIST and a verification of the primary standard correction factors. The mammography comparison will repeat two previously unpublished comparisons between PTB and NIST. The results show the standards to be in reasonable agreement within the standard uncertainty of the comparison of about 0.4 %. |
format | Online Article Text |
id | pubmed-4646528 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2009 |
publisher | [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology |
record_format | MEDLINE/PubMed |
spelling | pubmed-46465282016-08-08 Comparison of the NIST and PTB Air-Kerma Standards for Low-Energy X-Rays O’Brien, Michelle Bueermann, Ludwig J Res Natl Inst Stand Technol Article A comparison has been made of the air-kerma standards for low-energy x rays at the National Institute of Standards and Technology (NIST) and the Physikalisch-Technische Bundesanstalt (PTB). The comparison involved a series of measurements at the PTB and the NIST using the air-kerma standards and two NIST reference-class transfer ionization chamber standards. Results are presented for the reference radiation beam qualities in the range from 25 kV to 50 kV for low energy x rays, including the techniques used for mammography dose traceability. The tungsten generated reference radiation qualities, between 25 kV and 50 kV used for this comparison, are new to NIST; therefore this comparison will serve as the preliminary comparison for NIST and a verification of the primary standard correction factors. The mammography comparison will repeat two previously unpublished comparisons between PTB and NIST. The results show the standards to be in reasonable agreement within the standard uncertainty of the comparison of about 0.4 %. [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 2009 2009-12-01 /pmc/articles/PMC4646528/ /pubmed/27504231 http://dx.doi.org/10.6028/jres.114.023 Text en https://creativecommons.org/publicdomain/zero/1.0/ The Journal of Research of the National Institute of Standards and Technology is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright. |
spellingShingle | Article O’Brien, Michelle Bueermann, Ludwig Comparison of the NIST and PTB Air-Kerma Standards for Low-Energy X-Rays |
title | Comparison of the NIST and PTB Air-Kerma Standards for Low-Energy X-Rays |
title_full | Comparison of the NIST and PTB Air-Kerma Standards for Low-Energy X-Rays |
title_fullStr | Comparison of the NIST and PTB Air-Kerma Standards for Low-Energy X-Rays |
title_full_unstemmed | Comparison of the NIST and PTB Air-Kerma Standards for Low-Energy X-Rays |
title_short | Comparison of the NIST and PTB Air-Kerma Standards for Low-Energy X-Rays |
title_sort | comparison of the nist and ptb air-kerma standards for low-energy x-rays |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4646528/ https://www.ncbi.nlm.nih.gov/pubmed/27504231 http://dx.doi.org/10.6028/jres.114.023 |
work_keys_str_mv | AT obrienmichelle comparisonofthenistandptbairkermastandardsforlowenergyxrays AT bueermannludwig comparisonofthenistandptbairkermastandardsforlowenergyxrays |