Cargando…
Buttonhole Cannulation Is Not Associated with More AVF Infections in a Low-Care Satellite Dialysis Unit: A Long-Term Longitudinal Study
BACKGROUND: Buttonhole cannulation (BHC) has been associated with a greater risk of arteriovenous fistula (AVF)-related infections and septicemia than the rope ladder cannulation (RLC) in in-center hemodialysis (HD). Such infections have never been studied in satellite HD units. STUDY DESIGN: Retros...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4648583/ https://www.ncbi.nlm.nih.gov/pubmed/26575267 http://dx.doi.org/10.1371/journal.pone.0142256 |
_version_ | 1782401258888364032 |
---|---|
author | Béchade, Clémence Goovaerts, Tony Cougnet, Philippe Labriola, Laura Jadoul, Michel Goffin, Eric |
author_facet | Béchade, Clémence Goovaerts, Tony Cougnet, Philippe Labriola, Laura Jadoul, Michel Goffin, Eric |
author_sort | Béchade, Clémence |
collection | PubMed |
description | BACKGROUND: Buttonhole cannulation (BHC) has been associated with a greater risk of arteriovenous fistula (AVF)-related infections and septicemia than the rope ladder cannulation (RLC) in in-center hemodialysis (HD). Such infections have never been studied in satellite HD units. STUDY DESIGN: Retrospective single center study. SETTING AND PARTICIPANT: All patients in our satellite HD unit using a native AVF from 1 January, 1990, to 31 December, 2012. STUDY PERIOD: Two different kinds of cannulation have been used during the study period: From 1 January, 1990 to 1, January, 1998 RLC was used in the unit (period 1). After 1 January, 1998 onwards, all the patients were switched within 3 months to BHC (period 2). OUTCOMES: Three different infectious events were observed during the two periods: local AVF infection, bacteremia, and combined infection. The aim of this study was to evaluate the incidence of AVF-related infections in our low-care HD unit and to determine whether BHC is associated with an increased risk of infection in this population. RESULTS: 162 patients were analyzed; 68 patients participated to period 1 and 115 to period 2. Sixteen infectious events occurred. Incidences of AVF-related infectious events were 0.05 [95% CI, 0.02–0.16] and 0.13/1000 AVF-days [95% CI, 0.0.8–0.23], for period 1 and 2 (p = 0.44) respectively. Recurrence of AVF-related infection was observed only during period 2. Unadjusted incidence rate ratio (IRR) of all infections was 0.39 (95%CI 0.12–1.37). Two complicated infections occurred during the study period: one in period 1 and one in period 2. LIMITATIONS: Observational retrospective single centre study CONCLUSIONS: BHC is not associated with an increased infectious incidence in our HD population from a satellite dialysis unit. In the rare patients with AVF-related infection it seems necessary to change cannulation sites as recurrence of infection might be an event more frequent with BHC. |
format | Online Article Text |
id | pubmed-4648583 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-46485832015-11-25 Buttonhole Cannulation Is Not Associated with More AVF Infections in a Low-Care Satellite Dialysis Unit: A Long-Term Longitudinal Study Béchade, Clémence Goovaerts, Tony Cougnet, Philippe Labriola, Laura Jadoul, Michel Goffin, Eric PLoS One Research Article BACKGROUND: Buttonhole cannulation (BHC) has been associated with a greater risk of arteriovenous fistula (AVF)-related infections and septicemia than the rope ladder cannulation (RLC) in in-center hemodialysis (HD). Such infections have never been studied in satellite HD units. STUDY DESIGN: Retrospective single center study. SETTING AND PARTICIPANT: All patients in our satellite HD unit using a native AVF from 1 January, 1990, to 31 December, 2012. STUDY PERIOD: Two different kinds of cannulation have been used during the study period: From 1 January, 1990 to 1, January, 1998 RLC was used in the unit (period 1). After 1 January, 1998 onwards, all the patients were switched within 3 months to BHC (period 2). OUTCOMES: Three different infectious events were observed during the two periods: local AVF infection, bacteremia, and combined infection. The aim of this study was to evaluate the incidence of AVF-related infections in our low-care HD unit and to determine whether BHC is associated with an increased risk of infection in this population. RESULTS: 162 patients were analyzed; 68 patients participated to period 1 and 115 to period 2. Sixteen infectious events occurred. Incidences of AVF-related infectious events were 0.05 [95% CI, 0.02–0.16] and 0.13/1000 AVF-days [95% CI, 0.0.8–0.23], for period 1 and 2 (p = 0.44) respectively. Recurrence of AVF-related infection was observed only during period 2. Unadjusted incidence rate ratio (IRR) of all infections was 0.39 (95%CI 0.12–1.37). Two complicated infections occurred during the study period: one in period 1 and one in period 2. LIMITATIONS: Observational retrospective single centre study CONCLUSIONS: BHC is not associated with an increased infectious incidence in our HD population from a satellite dialysis unit. In the rare patients with AVF-related infection it seems necessary to change cannulation sites as recurrence of infection might be an event more frequent with BHC. Public Library of Science 2015-11-17 /pmc/articles/PMC4648583/ /pubmed/26575267 http://dx.doi.org/10.1371/journal.pone.0142256 Text en © 2015 Béchade et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Béchade, Clémence Goovaerts, Tony Cougnet, Philippe Labriola, Laura Jadoul, Michel Goffin, Eric Buttonhole Cannulation Is Not Associated with More AVF Infections in a Low-Care Satellite Dialysis Unit: A Long-Term Longitudinal Study |
title | Buttonhole Cannulation Is Not Associated with More AVF Infections in a Low-Care Satellite Dialysis Unit: A Long-Term Longitudinal Study |
title_full | Buttonhole Cannulation Is Not Associated with More AVF Infections in a Low-Care Satellite Dialysis Unit: A Long-Term Longitudinal Study |
title_fullStr | Buttonhole Cannulation Is Not Associated with More AVF Infections in a Low-Care Satellite Dialysis Unit: A Long-Term Longitudinal Study |
title_full_unstemmed | Buttonhole Cannulation Is Not Associated with More AVF Infections in a Low-Care Satellite Dialysis Unit: A Long-Term Longitudinal Study |
title_short | Buttonhole Cannulation Is Not Associated with More AVF Infections in a Low-Care Satellite Dialysis Unit: A Long-Term Longitudinal Study |
title_sort | buttonhole cannulation is not associated with more avf infections in a low-care satellite dialysis unit: a long-term longitudinal study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4648583/ https://www.ncbi.nlm.nih.gov/pubmed/26575267 http://dx.doi.org/10.1371/journal.pone.0142256 |
work_keys_str_mv | AT bechadeclemence buttonholecannulationisnotassociatedwithmoreavfinfectionsinalowcaresatellitedialysisunitalongtermlongitudinalstudy AT goovaertstony buttonholecannulationisnotassociatedwithmoreavfinfectionsinalowcaresatellitedialysisunitalongtermlongitudinalstudy AT cougnetphilippe buttonholecannulationisnotassociatedwithmoreavfinfectionsinalowcaresatellitedialysisunitalongtermlongitudinalstudy AT labriolalaura buttonholecannulationisnotassociatedwithmoreavfinfectionsinalowcaresatellitedialysisunitalongtermlongitudinalstudy AT jadoulmichel buttonholecannulationisnotassociatedwithmoreavfinfectionsinalowcaresatellitedialysisunitalongtermlongitudinalstudy AT goffineric buttonholecannulationisnotassociatedwithmoreavfinfectionsinalowcaresatellitedialysisunitalongtermlongitudinalstudy |