Cargando…

Effect of difference in occlusal contact area of mandibular free-end edentulous area implants on periodontal mechanosensitive threshold of adjacent premolars

Implant treatment is believed to cause minimal invasion of remaining teeth. However, few studies have examined teeth adjacent to an implant region. Therefore, this study investigated the effect of occlusal contact size of implants on the periodontal mechanosensitive threshold of adjacent premolars....

Descripción completa

Detalles Bibliográficos
Autores principales: Terauchi, Rie, Arai, Korenori, Tanaka, Masahiro, Kawazoe, Takayoshi, Baba, Shunsuke
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4648849/
https://www.ncbi.nlm.nih.gov/pubmed/26609505
http://dx.doi.org/10.1186/s40064-015-1497-2
_version_ 1782401281119223808
author Terauchi, Rie
Arai, Korenori
Tanaka, Masahiro
Kawazoe, Takayoshi
Baba, Shunsuke
author_facet Terauchi, Rie
Arai, Korenori
Tanaka, Masahiro
Kawazoe, Takayoshi
Baba, Shunsuke
author_sort Terauchi, Rie
collection PubMed
description Implant treatment is believed to cause minimal invasion of remaining teeth. However, few studies have examined teeth adjacent to an implant region. Therefore, this study investigated the effect of occlusal contact size of implants on the periodontal mechanosensitive threshold of adjacent premolars. A cross-sectional study design was adopted. The Department of Oral Implantology, Osaka Dental University, was the setting where patients underwent implant treatment in the mandibular free-end edentulous area. The study population comprised of 87 patients (109 teeth) who underwent follow-up observation for at least 3 years following implant superstructure placement. As variables, age, sex, duration following superstructure placement, presence or absence of dental pulp, occlusal contact area, and periodontal mechanosensitive threshold were considered. The occlusal contact area was measured using Blue Silicone(®)and Bite Eye BE-I(®). Periodontal mechanosensitive threshold were measured using von Frey hair. As quantitative variables for periodontal mechanosensitive threshold, we divided subjects into two groups: normal (≤5 g) and high (≥5.1 g). For statistical analysis, we compared the two groups for the sensation thresholds using the Chi square test for categorical data and the Mann–Whitney U test for continuous volume data. For variables in which a significant difference was noted, we calculated the odds ratio (95 % confidence interval) and the effective dose. There were 93 teeth in the normal group and 16 teeth in the high group based on periodontal mechanosensitive threshold. Comparison of the two groups indicated no significant differences associated with age, sex, duration following superstructure placement, or presence or absence of dental pulp. A significant difference was noted with regard to occlusal contact area, with several high group subjects belonging to the small contact group (odds ratio: 4.75 [1.42–15.87]; effective dose: 0.29). The results of this study suggest an association between implant occlusal contact area and the periodontal mechanosensitive threshold of adjacent premolars. Smaller occlusal contact application resulted in an increased threshold. It appears that prosthodontic treatment should aim not only to improve occlusal function but also to maintain oromandibular function with regard to the preservation of remaining teeth.
format Online
Article
Text
id pubmed-4648849
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-46488492015-11-25 Effect of difference in occlusal contact area of mandibular free-end edentulous area implants on periodontal mechanosensitive threshold of adjacent premolars Terauchi, Rie Arai, Korenori Tanaka, Masahiro Kawazoe, Takayoshi Baba, Shunsuke Springerplus Research Implant treatment is believed to cause minimal invasion of remaining teeth. However, few studies have examined teeth adjacent to an implant region. Therefore, this study investigated the effect of occlusal contact size of implants on the periodontal mechanosensitive threshold of adjacent premolars. A cross-sectional study design was adopted. The Department of Oral Implantology, Osaka Dental University, was the setting where patients underwent implant treatment in the mandibular free-end edentulous area. The study population comprised of 87 patients (109 teeth) who underwent follow-up observation for at least 3 years following implant superstructure placement. As variables, age, sex, duration following superstructure placement, presence or absence of dental pulp, occlusal contact area, and periodontal mechanosensitive threshold were considered. The occlusal contact area was measured using Blue Silicone(®)and Bite Eye BE-I(®). Periodontal mechanosensitive threshold were measured using von Frey hair. As quantitative variables for periodontal mechanosensitive threshold, we divided subjects into two groups: normal (≤5 g) and high (≥5.1 g). For statistical analysis, we compared the two groups for the sensation thresholds using the Chi square test for categorical data and the Mann–Whitney U test for continuous volume data. For variables in which a significant difference was noted, we calculated the odds ratio (95 % confidence interval) and the effective dose. There were 93 teeth in the normal group and 16 teeth in the high group based on periodontal mechanosensitive threshold. Comparison of the two groups indicated no significant differences associated with age, sex, duration following superstructure placement, or presence or absence of dental pulp. A significant difference was noted with regard to occlusal contact area, with several high group subjects belonging to the small contact group (odds ratio: 4.75 [1.42–15.87]; effective dose: 0.29). The results of this study suggest an association between implant occlusal contact area and the periodontal mechanosensitive threshold of adjacent premolars. Smaller occlusal contact application resulted in an increased threshold. It appears that prosthodontic treatment should aim not only to improve occlusal function but also to maintain oromandibular function with regard to the preservation of remaining teeth. Springer International Publishing 2015-11-17 /pmc/articles/PMC4648849/ /pubmed/26609505 http://dx.doi.org/10.1186/s40064-015-1497-2 Text en © Terauchi et al. 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Research
Terauchi, Rie
Arai, Korenori
Tanaka, Masahiro
Kawazoe, Takayoshi
Baba, Shunsuke
Effect of difference in occlusal contact area of mandibular free-end edentulous area implants on periodontal mechanosensitive threshold of adjacent premolars
title Effect of difference in occlusal contact area of mandibular free-end edentulous area implants on periodontal mechanosensitive threshold of adjacent premolars
title_full Effect of difference in occlusal contact area of mandibular free-end edentulous area implants on periodontal mechanosensitive threshold of adjacent premolars
title_fullStr Effect of difference in occlusal contact area of mandibular free-end edentulous area implants on periodontal mechanosensitive threshold of adjacent premolars
title_full_unstemmed Effect of difference in occlusal contact area of mandibular free-end edentulous area implants on periodontal mechanosensitive threshold of adjacent premolars
title_short Effect of difference in occlusal contact area of mandibular free-end edentulous area implants on periodontal mechanosensitive threshold of adjacent premolars
title_sort effect of difference in occlusal contact area of mandibular free-end edentulous area implants on periodontal mechanosensitive threshold of adjacent premolars
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4648849/
https://www.ncbi.nlm.nih.gov/pubmed/26609505
http://dx.doi.org/10.1186/s40064-015-1497-2
work_keys_str_mv AT terauchirie effectofdifferenceinocclusalcontactareaofmandibularfreeendedentulousareaimplantsonperiodontalmechanosensitivethresholdofadjacentpremolars
AT araikorenori effectofdifferenceinocclusalcontactareaofmandibularfreeendedentulousareaimplantsonperiodontalmechanosensitivethresholdofadjacentpremolars
AT tanakamasahiro effectofdifferenceinocclusalcontactareaofmandibularfreeendedentulousareaimplantsonperiodontalmechanosensitivethresholdofadjacentpremolars
AT kawazoetakayoshi effectofdifferenceinocclusalcontactareaofmandibularfreeendedentulousareaimplantsonperiodontalmechanosensitivethresholdofadjacentpremolars
AT babashunsuke effectofdifferenceinocclusalcontactareaofmandibularfreeendedentulousareaimplantsonperiodontalmechanosensitivethresholdofadjacentpremolars