Procedures for Wavelength Calibration and Spectral Response Correction of CCD Array Spectrometers
This work describes a procedure for acquiring a spectrum of an analyte over an extended range of wavelengths and validating the wavelength and intensity assignments. To acquire a spectrum over an extended range of wavelengths with a spectrometer with a charge coupled device (CCD) array detector, it...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
[Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4651606/ https://www.ncbi.nlm.nih.gov/pubmed/27504223 http://dx.doi.org/10.6028/jres.114.015 |
_version_ | 1782401661620191232 |
---|---|
author | Gaigalas, A. K. Wang, Lili He, Hua-Jun DeRose, Paul |
author_facet | Gaigalas, A. K. Wang, Lili He, Hua-Jun DeRose, Paul |
author_sort | Gaigalas, A. K. |
collection | PubMed |
description | This work describes a procedure for acquiring a spectrum of an analyte over an extended range of wavelengths and validating the wavelength and intensity assignments. To acquire a spectrum over an extended range of wavelengths with a spectrometer with a charge coupled device (CCD) array detector, it is necessary to acquire many partial spectra, each at a different angular position of the grating, and splice the partial spectra into a single extended spectrum. The splicing procedure exposes instrument dependent artifacts. It is demonstrated that by taking a spectrum of a reference irradiance source and making spectral correction, the artifacts exposed by the splicing are removed from the analyte spectrum. This is because the irradiance reference spectrum contains the same artifacts as the analyte spectrum. The artifacts exposed by the splicing depend on the wavelength of the splice; therefore it is important to measure the irradiance reference spectrum for the same range of wavelengths used to measure the spectrum of the analyte solution. In other words, there is no general spectral correction factor which is applicable to spectra taken for different range of wavelengths. The wavelength calibration is also carried out by splicing many partial spectra from a source like a krypton lamp. However the wavelength assignments are not sensitive to the splicing procedure and the same wavelength calibration can be used for spectra acquired over different extended wavelength ranges. The wavelength calibration checks the validity of the setting of the grating angular position, and the assignment of wavelengths to individual pixels on the CCD array detector. The procedure is illustrated by measuring the spectrum of an orange glass and the spectrum of a suspension of microalgae. |
format | Online Article Text |
id | pubmed-4651606 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2009 |
publisher | [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology |
record_format | MEDLINE/PubMed |
spelling | pubmed-46516062016-08-08 Procedures for Wavelength Calibration and Spectral Response Correction of CCD Array Spectrometers Gaigalas, A. K. Wang, Lili He, Hua-Jun DeRose, Paul J Res Natl Inst Stand Technol Article This work describes a procedure for acquiring a spectrum of an analyte over an extended range of wavelengths and validating the wavelength and intensity assignments. To acquire a spectrum over an extended range of wavelengths with a spectrometer with a charge coupled device (CCD) array detector, it is necessary to acquire many partial spectra, each at a different angular position of the grating, and splice the partial spectra into a single extended spectrum. The splicing procedure exposes instrument dependent artifacts. It is demonstrated that by taking a spectrum of a reference irradiance source and making spectral correction, the artifacts exposed by the splicing are removed from the analyte spectrum. This is because the irradiance reference spectrum contains the same artifacts as the analyte spectrum. The artifacts exposed by the splicing depend on the wavelength of the splice; therefore it is important to measure the irradiance reference spectrum for the same range of wavelengths used to measure the spectrum of the analyte solution. In other words, there is no general spectral correction factor which is applicable to spectra taken for different range of wavelengths. The wavelength calibration is also carried out by splicing many partial spectra from a source like a krypton lamp. However the wavelength assignments are not sensitive to the splicing procedure and the same wavelength calibration can be used for spectra acquired over different extended wavelength ranges. The wavelength calibration checks the validity of the setting of the grating angular position, and the assignment of wavelengths to individual pixels on the CCD array detector. The procedure is illustrated by measuring the spectrum of an orange glass and the spectrum of a suspension of microalgae. [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 2009 2009-08-01 /pmc/articles/PMC4651606/ /pubmed/27504223 http://dx.doi.org/10.6028/jres.114.015 Text en https://creativecommons.org/publicdomain/zero/1.0/ The Journal of Research of the National Institute of Standards and Technology is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright. |
spellingShingle | Article Gaigalas, A. K. Wang, Lili He, Hua-Jun DeRose, Paul Procedures for Wavelength Calibration and Spectral Response Correction of CCD Array Spectrometers |
title | Procedures for Wavelength Calibration and Spectral Response Correction of CCD Array Spectrometers |
title_full | Procedures for Wavelength Calibration and Spectral Response Correction of CCD Array Spectrometers |
title_fullStr | Procedures for Wavelength Calibration and Spectral Response Correction of CCD Array Spectrometers |
title_full_unstemmed | Procedures for Wavelength Calibration and Spectral Response Correction of CCD Array Spectrometers |
title_short | Procedures for Wavelength Calibration and Spectral Response Correction of CCD Array Spectrometers |
title_sort | procedures for wavelength calibration and spectral response correction of ccd array spectrometers |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4651606/ https://www.ncbi.nlm.nih.gov/pubmed/27504223 http://dx.doi.org/10.6028/jres.114.015 |
work_keys_str_mv | AT gaigalasak proceduresforwavelengthcalibrationandspectralresponsecorrectionofccdarrayspectrometers AT wanglili proceduresforwavelengthcalibrationandspectralresponsecorrectionofccdarrayspectrometers AT hehuajun proceduresforwavelengthcalibrationandspectralresponsecorrectionofccdarrayspectrometers AT derosepaul proceduresforwavelengthcalibrationandspectralresponsecorrectionofccdarrayspectrometers |