Assessment of Corneal Biomechanical Properties by CorVis ST in Patients with Dry Eye and in Healthy Subjects

Purpose. To investigate corneal biomechanical properties in patients with dry eye and in healthy subjects using Corneal Visualization Scheimpflug Technology (CorVis ST). Methods. Biomechanical parameters were measured using CorVis ST in 28 eyes of 28 patients with dry eye (dry eye group) and 26 norm...

Descripción completa

Detalles Bibliográficos
Autores principales: Long, Qin, Wang, Jingyi, Yang, Xue, Jin, Yumei, Ai, Fengrong, Li, Ying
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4655069/
https://www.ncbi.nlm.nih.gov/pubmed/26634151
http://dx.doi.org/10.1155/2015/380624
_version_ 1782402144084688896
author Long, Qin
Wang, Jingyi
Yang, Xue
Jin, Yumei
Ai, Fengrong
Li, Ying
author_facet Long, Qin
Wang, Jingyi
Yang, Xue
Jin, Yumei
Ai, Fengrong
Li, Ying
author_sort Long, Qin
collection PubMed
description Purpose. To investigate corneal biomechanical properties in patients with dry eye and in healthy subjects using Corneal Visualization Scheimpflug Technology (CorVis ST). Methods. Biomechanical parameters were measured using CorVis ST in 28 eyes of 28 patients with dry eye (dry eye group) and 26 normal subjects (control group). The Schirmer I test value, tear film break-up time (TBUT), and corneal staining score (CSS) were recorded for each eye. Biomechanical properties were compared between the two groups and bivariate correlation analysis was used to assess the relationship between biomechanical parameters and dry eye signs. Results. Only one of the ten biomechanical parameters was significantly different between the two groups. Patients in the dry eye group had significantly lower highest concavity time (HC-time) (P = 0.02) than the control group. Correlation analysis showed a significant negative correlation between HC-time and CSS with marginal P value (ρ = −0.39, P = 0.04) in the dry eye group. Conclusions. The corneal biomechanical parameter of HC-time is reduced in dry eyes compared to normal eyes. There was also a very weak but significant negative correlation between HC-time and CSS in the dry eye group, indicating that ocular surface damage can give rise to a more compliant cornea in dry eyes.
format Online
Article
Text
id pubmed-4655069
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-46550692015-12-02 Assessment of Corneal Biomechanical Properties by CorVis ST in Patients with Dry Eye and in Healthy Subjects Long, Qin Wang, Jingyi Yang, Xue Jin, Yumei Ai, Fengrong Li, Ying J Ophthalmol Research Article Purpose. To investigate corneal biomechanical properties in patients with dry eye and in healthy subjects using Corneal Visualization Scheimpflug Technology (CorVis ST). Methods. Biomechanical parameters were measured using CorVis ST in 28 eyes of 28 patients with dry eye (dry eye group) and 26 normal subjects (control group). The Schirmer I test value, tear film break-up time (TBUT), and corneal staining score (CSS) were recorded for each eye. Biomechanical properties were compared between the two groups and bivariate correlation analysis was used to assess the relationship between biomechanical parameters and dry eye signs. Results. Only one of the ten biomechanical parameters was significantly different between the two groups. Patients in the dry eye group had significantly lower highest concavity time (HC-time) (P = 0.02) than the control group. Correlation analysis showed a significant negative correlation between HC-time and CSS with marginal P value (ρ = −0.39, P = 0.04) in the dry eye group. Conclusions. The corneal biomechanical parameter of HC-time is reduced in dry eyes compared to normal eyes. There was also a very weak but significant negative correlation between HC-time and CSS in the dry eye group, indicating that ocular surface damage can give rise to a more compliant cornea in dry eyes. Hindawi Publishing Corporation 2015 2015-11-08 /pmc/articles/PMC4655069/ /pubmed/26634151 http://dx.doi.org/10.1155/2015/380624 Text en Copyright © 2015 Qin Long et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Long, Qin
Wang, Jingyi
Yang, Xue
Jin, Yumei
Ai, Fengrong
Li, Ying
Assessment of Corneal Biomechanical Properties by CorVis ST in Patients with Dry Eye and in Healthy Subjects
title Assessment of Corneal Biomechanical Properties by CorVis ST in Patients with Dry Eye and in Healthy Subjects
title_full Assessment of Corneal Biomechanical Properties by CorVis ST in Patients with Dry Eye and in Healthy Subjects
title_fullStr Assessment of Corneal Biomechanical Properties by CorVis ST in Patients with Dry Eye and in Healthy Subjects
title_full_unstemmed Assessment of Corneal Biomechanical Properties by CorVis ST in Patients with Dry Eye and in Healthy Subjects
title_short Assessment of Corneal Biomechanical Properties by CorVis ST in Patients with Dry Eye and in Healthy Subjects
title_sort assessment of corneal biomechanical properties by corvis st in patients with dry eye and in healthy subjects
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4655069/
https://www.ncbi.nlm.nih.gov/pubmed/26634151
http://dx.doi.org/10.1155/2015/380624
work_keys_str_mv AT longqin assessmentofcornealbiomechanicalpropertiesbycorvisstinpatientswithdryeyeandinhealthysubjects
AT wangjingyi assessmentofcornealbiomechanicalpropertiesbycorvisstinpatientswithdryeyeandinhealthysubjects
AT yangxue assessmentofcornealbiomechanicalpropertiesbycorvisstinpatientswithdryeyeandinhealthysubjects
AT jinyumei assessmentofcornealbiomechanicalpropertiesbycorvisstinpatientswithdryeyeandinhealthysubjects
AT aifengrong assessmentofcornealbiomechanicalpropertiesbycorvisstinpatientswithdryeyeandinhealthysubjects
AT liying assessmentofcornealbiomechanicalpropertiesbycorvisstinpatientswithdryeyeandinhealthysubjects