BACKGROUND: Coronary magnetic resonance angiography (MRA) is usually obtained with a free-breathing navigator-gated 3D acquisition. Our aim was to develop an alternative breath-hold approach that would allow the coronary arteries to be evaluated in a much shorter time and without risk of degradation...

Descripción completa

Detalles Bibliográficos
Autores principales: Edelman, Robert R., Giri, S., Pursnani, A., Botelho, M. P. F., Li, W., Koktzoglou, I.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4655490/
https://www.ncbi.nlm.nih.gov/pubmed/26597281
http://dx.doi.org/10.1186/s12968-015-0205-2
_version_ 1782402205077209088
author Edelman, Robert R.
Giri, S.
Pursnani, A.
Botelho, M. P. F.
Li, W.
Koktzoglou, I.
author_facet Edelman, Robert R.
Giri, S.
Pursnani, A.
Botelho, M. P. F.
Li, W.
Koktzoglou, I.
author_sort Edelman, Robert R.
collection PubMed
description BACKGROUND: Coronary magnetic resonance angiography (MRA) is usually obtained with a free-breathing navigator-gated 3D acquisition. Our aim was to develop an alternative breath-hold approach that would allow the coronary arteries to be evaluated in a much shorter time and without risk of degradation by respiratory motion artifacts. For this purpose, we implemented a breath-hold, non-contrast-enhanced, quiescent-interval slice-selective (QISS) 2D technique. Sequence performance was compared at 1.5 and 3 Tesla using both radial and Cartesian k-space trajectories. METHODS: The left coronary circulation was imaged in six healthy subjects and two patients with coronary artery disease. Breath-hold QISS was compared with T2-prepared 2D balanced steady-state free-precession (bSSFP) and free-breathing, navigator-gated 3D bSSFP. RESULTS: Approximately 10 2.1-mm thick slices were acquired in a single ~20-s breath-hold using two-shot QISS. QISS contrast-to-noise ratio (CNR) was 1.5-fold higher at 3 Tesla than at 1.5 Tesla. Cartesian QISS provided the best coronary-to-myocardium CNR, whereas radial QISS provided the sharpest coronary images. QISS image quality exceeded that of free-breathing 3D coronary MRA with few artifacts at either field strength. Compared with T2-prepared 2D bSSFP, multi-slice capability was not restricted by the specific absorption rate at 3 Tesla and pericardial fluid signal was better suppressed. In addition to depicting the coronary arteries, QISS could image intra-cardiac structures, pericardium, and the aortic root in arbitrary slice orientations. CONCLUSIONS: Breath-hold QISS is a simple, versatile, and time-efficient method for coronary MRA that provides excellent image quality at both 1.5 and 3 Tesla. Image quality exceeded that of free-breathing, navigator-gated 3D MRA in a much shorter scan time. QISS also allowed rapid multi-slice bright-blood, diastolic phase imaging of the heart, which may have complementary value to multi-phase cine imaging. We conclude that, with further clinical validation, QISS might provide an efficient alternative to commonly used free-breathing coronary MRA techniques.
format Online
Article
Text
id pubmed-4655490
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-46554902015-11-25 Breath-hold imaging of the coronary arteries using Quiescent-Interval Slice-Selective (QISS) magnetic resonance angiography: pilot study at 1.5 Tesla and 3 Tesla Edelman, Robert R. Giri, S. Pursnani, A. Botelho, M. P. F. Li, W. Koktzoglou, I. J Cardiovasc Magn Reson Technical Notes BACKGROUND: Coronary magnetic resonance angiography (MRA) is usually obtained with a free-breathing navigator-gated 3D acquisition. Our aim was to develop an alternative breath-hold approach that would allow the coronary arteries to be evaluated in a much shorter time and without risk of degradation by respiratory motion artifacts. For this purpose, we implemented a breath-hold, non-contrast-enhanced, quiescent-interval slice-selective (QISS) 2D technique. Sequence performance was compared at 1.5 and 3 Tesla using both radial and Cartesian k-space trajectories. METHODS: The left coronary circulation was imaged in six healthy subjects and two patients with coronary artery disease. Breath-hold QISS was compared with T2-prepared 2D balanced steady-state free-precession (bSSFP) and free-breathing, navigator-gated 3D bSSFP. RESULTS: Approximately 10 2.1-mm thick slices were acquired in a single ~20-s breath-hold using two-shot QISS. QISS contrast-to-noise ratio (CNR) was 1.5-fold higher at 3 Tesla than at 1.5 Tesla. Cartesian QISS provided the best coronary-to-myocardium CNR, whereas radial QISS provided the sharpest coronary images. QISS image quality exceeded that of free-breathing 3D coronary MRA with few artifacts at either field strength. Compared with T2-prepared 2D bSSFP, multi-slice capability was not restricted by the specific absorption rate at 3 Tesla and pericardial fluid signal was better suppressed. In addition to depicting the coronary arteries, QISS could image intra-cardiac structures, pericardium, and the aortic root in arbitrary slice orientations. CONCLUSIONS: Breath-hold QISS is a simple, versatile, and time-efficient method for coronary MRA that provides excellent image quality at both 1.5 and 3 Tesla. Image quality exceeded that of free-breathing, navigator-gated 3D MRA in a much shorter scan time. QISS also allowed rapid multi-slice bright-blood, diastolic phase imaging of the heart, which may have complementary value to multi-phase cine imaging. We conclude that, with further clinical validation, QISS might provide an efficient alternative to commonly used free-breathing coronary MRA techniques. BioMed Central 2015-11-23 /pmc/articles/PMC4655490/ /pubmed/26597281 http://dx.doi.org/10.1186/s12968-015-0205-2 Text en © Edelman et al. 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Technical Notes
Edelman, Robert R.
Giri, S.
Pursnani, A.
Botelho, M. P. F.
Li, W.
Koktzoglou, I.
Breath-hold imaging of the coronary arteries using Quiescent-Interval Slice-Selective (QISS) magnetic resonance angiography: pilot study at 1.5 Tesla and 3 Tesla
title Breath-hold imaging of the coronary arteries using Quiescent-Interval Slice-Selective (QISS) magnetic resonance angiography: pilot study at 1.5 Tesla and 3 Tesla
title_full Breath-hold imaging of the coronary arteries using Quiescent-Interval Slice-Selective (QISS) magnetic resonance angiography: pilot study at 1.5 Tesla and 3 Tesla
title_fullStr Breath-hold imaging of the coronary arteries using Quiescent-Interval Slice-Selective (QISS) magnetic resonance angiography: pilot study at 1.5 Tesla and 3 Tesla
title_full_unstemmed Breath-hold imaging of the coronary arteries using Quiescent-Interval Slice-Selective (QISS) magnetic resonance angiography: pilot study at 1.5 Tesla and 3 Tesla
title_short Breath-hold imaging of the coronary arteries using Quiescent-Interval Slice-Selective (QISS) magnetic resonance angiography: pilot study at 1.5 Tesla and 3 Tesla
title_sort breath-hold imaging of the coronary arteries using quiescent-interval slice-selective (qiss) magnetic resonance angiography: pilot study at 1.5 tesla and 3 tesla
topic Technical Notes
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4655490/
https://www.ncbi.nlm.nih.gov/pubmed/26597281
http://dx.doi.org/10.1186/s12968-015-0205-2
work_keys_str_mv AT edelmanrobertr breathholdimagingofthecoronaryarteriesusingquiescentintervalsliceselectiveqissmagneticresonanceangiographypilotstudyat15teslaand3tesla
AT giris breathholdimagingofthecoronaryarteriesusingquiescentintervalsliceselectiveqissmagneticresonanceangiographypilotstudyat15teslaand3tesla
AT pursnania breathholdimagingofthecoronaryarteriesusingquiescentintervalsliceselectiveqissmagneticresonanceangiographypilotstudyat15teslaand3tesla
AT botelhompf breathholdimagingofthecoronaryarteriesusingquiescentintervalsliceselectiveqissmagneticresonanceangiographypilotstudyat15teslaand3tesla
AT liw breathholdimagingofthecoronaryarteriesusingquiescentintervalsliceselectiveqissmagneticresonanceangiographypilotstudyat15teslaand3tesla
AT koktzogloui breathholdimagingofthecoronaryarteriesusingquiescentintervalsliceselectiveqissmagneticresonanceangiographypilotstudyat15teslaand3tesla