Cargando…
Comparison of the NIST and BIPM Standards for Air Kerma in Medium-Energy X-Rays
A comparison has been made of the air-kerma standards for medium-energy x-rays of the National Institute of Standards and Technology (NIST) and the Bureau International des Poids et Mesures (BIPM). The comparison involved a series of measurements at the BIPM and the NIST using the air-kerma standard...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
[Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
2006
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4657787/ https://www.ncbi.nlm.nih.gov/pubmed/27274940 http://dx.doi.org/10.6028/jres.111.028 |
_version_ | 1782402421015707648 |
---|---|
author | Burns, D. T. O’Brien, M. |
author_facet | Burns, D. T. O’Brien, M. |
author_sort | Burns, D. T. |
collection | PubMed |
description | A comparison has been made of the air-kerma standards for medium-energy x-rays of the National Institute of Standards and Technology (NIST) and the Bureau International des Poids et Mesures (BIPM). The comparison involved a series of measurements at the BIPM and the NIST using the air-kerma standards and three NIST reference-class transfer ionization chamber standards. Reference beam qualities in the range from 100 kV to 250 kV were used. The results show the standards to be in reasonable agreement within the combined standard uncertainty of the comparison of 0.37 %, although a significant trend with radiation quality is observed and the possible sources discussed. |
format | Online Article Text |
id | pubmed-4657787 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2006 |
publisher | [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology |
record_format | MEDLINE/PubMed |
spelling | pubmed-46577872016-06-03 Comparison of the NIST and BIPM Standards for Air Kerma in Medium-Energy X-Rays Burns, D. T. O’Brien, M. J Res Natl Inst Stand Technol Article A comparison has been made of the air-kerma standards for medium-energy x-rays of the National Institute of Standards and Technology (NIST) and the Bureau International des Poids et Mesures (BIPM). The comparison involved a series of measurements at the BIPM and the NIST using the air-kerma standards and three NIST reference-class transfer ionization chamber standards. Reference beam qualities in the range from 100 kV to 250 kV were used. The results show the standards to be in reasonable agreement within the combined standard uncertainty of the comparison of 0.37 %, although a significant trend with radiation quality is observed and the possible sources discussed. [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 2006 2006-10-01 /pmc/articles/PMC4657787/ /pubmed/27274940 http://dx.doi.org/10.6028/jres.111.028 Text en https://creativecommons.org/publicdomain/zero/1.0/ The Journal of Research of the National Institute of Standards and Technology is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright. |
spellingShingle | Article Burns, D. T. O’Brien, M. Comparison of the NIST and BIPM Standards for Air Kerma in Medium-Energy X-Rays |
title | Comparison of the NIST and BIPM Standards for Air Kerma in Medium-Energy X-Rays |
title_full | Comparison of the NIST and BIPM Standards for Air Kerma in Medium-Energy X-Rays |
title_fullStr | Comparison of the NIST and BIPM Standards for Air Kerma in Medium-Energy X-Rays |
title_full_unstemmed | Comparison of the NIST and BIPM Standards for Air Kerma in Medium-Energy X-Rays |
title_short | Comparison of the NIST and BIPM Standards for Air Kerma in Medium-Energy X-Rays |
title_sort | comparison of the nist and bipm standards for air kerma in medium-energy x-rays |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4657787/ https://www.ncbi.nlm.nih.gov/pubmed/27274940 http://dx.doi.org/10.6028/jres.111.028 |
work_keys_str_mv | AT burnsdt comparisonofthenistandbipmstandardsforairkermainmediumenergyxrays AT obrienm comparisonofthenistandbipmstandardsforairkermainmediumenergyxrays |