Cargando…

Comparison of the NIST and BIPM Standards for Air Kerma in Medium-Energy X-Rays

A comparison has been made of the air-kerma standards for medium-energy x-rays of the National Institute of Standards and Technology (NIST) and the Bureau International des Poids et Mesures (BIPM). The comparison involved a series of measurements at the BIPM and the NIST using the air-kerma standard...

Descripción completa

Detalles Bibliográficos
Autores principales: Burns, D. T., O’Brien, M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 2006
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4657787/
https://www.ncbi.nlm.nih.gov/pubmed/27274940
http://dx.doi.org/10.6028/jres.111.028
_version_ 1782402421015707648
author Burns, D. T.
O’Brien, M.
author_facet Burns, D. T.
O’Brien, M.
author_sort Burns, D. T.
collection PubMed
description A comparison has been made of the air-kerma standards for medium-energy x-rays of the National Institute of Standards and Technology (NIST) and the Bureau International des Poids et Mesures (BIPM). The comparison involved a series of measurements at the BIPM and the NIST using the air-kerma standards and three NIST reference-class transfer ionization chamber standards. Reference beam qualities in the range from 100 kV to 250 kV were used. The results show the standards to be in reasonable agreement within the combined standard uncertainty of the comparison of 0.37 %, although a significant trend with radiation quality is observed and the possible sources discussed.
format Online
Article
Text
id pubmed-4657787
institution National Center for Biotechnology Information
language English
publishDate 2006
publisher [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
record_format MEDLINE/PubMed
spelling pubmed-46577872016-06-03 Comparison of the NIST and BIPM Standards for Air Kerma in Medium-Energy X-Rays Burns, D. T. O’Brien, M. J Res Natl Inst Stand Technol Article A comparison has been made of the air-kerma standards for medium-energy x-rays of the National Institute of Standards and Technology (NIST) and the Bureau International des Poids et Mesures (BIPM). The comparison involved a series of measurements at the BIPM and the NIST using the air-kerma standards and three NIST reference-class transfer ionization chamber standards. Reference beam qualities in the range from 100 kV to 250 kV were used. The results show the standards to be in reasonable agreement within the combined standard uncertainty of the comparison of 0.37 %, although a significant trend with radiation quality is observed and the possible sources discussed. [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 2006 2006-10-01 /pmc/articles/PMC4657787/ /pubmed/27274940 http://dx.doi.org/10.6028/jres.111.028 Text en https://creativecommons.org/publicdomain/zero/1.0/ The Journal of Research of the National Institute of Standards and Technology is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright.
spellingShingle Article
Burns, D. T.
O’Brien, M.
Comparison of the NIST and BIPM Standards for Air Kerma in Medium-Energy X-Rays
title Comparison of the NIST and BIPM Standards for Air Kerma in Medium-Energy X-Rays
title_full Comparison of the NIST and BIPM Standards for Air Kerma in Medium-Energy X-Rays
title_fullStr Comparison of the NIST and BIPM Standards for Air Kerma in Medium-Energy X-Rays
title_full_unstemmed Comparison of the NIST and BIPM Standards for Air Kerma in Medium-Energy X-Rays
title_short Comparison of the NIST and BIPM Standards for Air Kerma in Medium-Energy X-Rays
title_sort comparison of the nist and bipm standards for air kerma in medium-energy x-rays
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4657787/
https://www.ncbi.nlm.nih.gov/pubmed/27274940
http://dx.doi.org/10.6028/jres.111.028
work_keys_str_mv AT burnsdt comparisonofthenistandbipmstandardsforairkermainmediumenergyxrays
AT obrienm comparisonofthenistandbipmstandardsforairkermainmediumenergyxrays