Cargando…

Is High Temporal Resolution Achievable for Paediatric Cardiac Acquisitions during Several Heart Beats? Illustration with Cardiac Phase Contrast Cine-MRI

BACKGROUND: During paediatric cardiac Cine-MRI, data acquired during cycles of different lengths must be combined. Most of the time, Feinstein’s model is used to project multiple cardiac cycles of variable lengths into a mean cycle. OBJECTIVE: To assess the effect of Feinstein projection on temporal...

Descripción completa

Detalles Bibliográficos
Autores principales: Bonnemains, Laurent, Odille, Freddy, Meyer, Christophe, Hossu, Gabriella, Felblinger, Jacques, Vuissoz, Pierre-André
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4658039/
https://www.ncbi.nlm.nih.gov/pubmed/26599755
http://dx.doi.org/10.1371/journal.pone.0143744
_version_ 1782402462387273728
author Bonnemains, Laurent
Odille, Freddy
Meyer, Christophe
Hossu, Gabriella
Felblinger, Jacques
Vuissoz, Pierre-André
author_facet Bonnemains, Laurent
Odille, Freddy
Meyer, Christophe
Hossu, Gabriella
Felblinger, Jacques
Vuissoz, Pierre-André
author_sort Bonnemains, Laurent
collection PubMed
description BACKGROUND: During paediatric cardiac Cine-MRI, data acquired during cycles of different lengths must be combined. Most of the time, Feinstein’s model is used to project multiple cardiac cycles of variable lengths into a mean cycle. OBJECTIVE: To assess the effect of Feinstein projection on temporal resolution of Cine-MRI. METHODS: 1/The temporal errors during Feinstein’s projection were computed in 306 cardiac cycles fully characterized by tissue Doppler imaging with 6-phase analysis (from a population of 7 children and young adults). 2/The effects of these temporal errors on tissue velocities were assessed by simulating typical tissue phase mapping acquisitions and reconstructions. 3/Myocardial velocities curves, extracted from high-resolution phase-contrast cine images, were compared for the 6 volunteers with lowest and highest heart rate variability, within a population of 36 young adults. RESULTS: 1/The mean of temporal misalignments was 30 ms over the cardiac cycle but reached 60 ms during early diastole. 2/During phase contrast MRI simulation, early diastole velocity peaks were diminished by 6.1 cm/s leading to virtual disappearance of isovolumic relaxation peaks. 3/The smoothing and erasing of isovolumic relaxation peaks was confirmed on tissue phase mapping velocity curves, between subjects with low and high heart rate variability (p = 0.05). CONCLUSIONS: Feinstein cardiac model creates temporal misalignments that impair high temporal resolution phase contrast cine imaging when beat-to-beat heart rate is changing.
format Online
Article
Text
id pubmed-4658039
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-46580392015-12-02 Is High Temporal Resolution Achievable for Paediatric Cardiac Acquisitions during Several Heart Beats? Illustration with Cardiac Phase Contrast Cine-MRI Bonnemains, Laurent Odille, Freddy Meyer, Christophe Hossu, Gabriella Felblinger, Jacques Vuissoz, Pierre-André PLoS One Research Article BACKGROUND: During paediatric cardiac Cine-MRI, data acquired during cycles of different lengths must be combined. Most of the time, Feinstein’s model is used to project multiple cardiac cycles of variable lengths into a mean cycle. OBJECTIVE: To assess the effect of Feinstein projection on temporal resolution of Cine-MRI. METHODS: 1/The temporal errors during Feinstein’s projection were computed in 306 cardiac cycles fully characterized by tissue Doppler imaging with 6-phase analysis (from a population of 7 children and young adults). 2/The effects of these temporal errors on tissue velocities were assessed by simulating typical tissue phase mapping acquisitions and reconstructions. 3/Myocardial velocities curves, extracted from high-resolution phase-contrast cine images, were compared for the 6 volunteers with lowest and highest heart rate variability, within a population of 36 young adults. RESULTS: 1/The mean of temporal misalignments was 30 ms over the cardiac cycle but reached 60 ms during early diastole. 2/During phase contrast MRI simulation, early diastole velocity peaks were diminished by 6.1 cm/s leading to virtual disappearance of isovolumic relaxation peaks. 3/The smoothing and erasing of isovolumic relaxation peaks was confirmed on tissue phase mapping velocity curves, between subjects with low and high heart rate variability (p = 0.05). CONCLUSIONS: Feinstein cardiac model creates temporal misalignments that impair high temporal resolution phase contrast cine imaging when beat-to-beat heart rate is changing. Public Library of Science 2015-11-24 /pmc/articles/PMC4658039/ /pubmed/26599755 http://dx.doi.org/10.1371/journal.pone.0143744 Text en © 2015 Bonnemains et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Bonnemains, Laurent
Odille, Freddy
Meyer, Christophe
Hossu, Gabriella
Felblinger, Jacques
Vuissoz, Pierre-André
Is High Temporal Resolution Achievable for Paediatric Cardiac Acquisitions during Several Heart Beats? Illustration with Cardiac Phase Contrast Cine-MRI
title Is High Temporal Resolution Achievable for Paediatric Cardiac Acquisitions during Several Heart Beats? Illustration with Cardiac Phase Contrast Cine-MRI
title_full Is High Temporal Resolution Achievable for Paediatric Cardiac Acquisitions during Several Heart Beats? Illustration with Cardiac Phase Contrast Cine-MRI
title_fullStr Is High Temporal Resolution Achievable for Paediatric Cardiac Acquisitions during Several Heart Beats? Illustration with Cardiac Phase Contrast Cine-MRI
title_full_unstemmed Is High Temporal Resolution Achievable for Paediatric Cardiac Acquisitions during Several Heart Beats? Illustration with Cardiac Phase Contrast Cine-MRI
title_short Is High Temporal Resolution Achievable for Paediatric Cardiac Acquisitions during Several Heart Beats? Illustration with Cardiac Phase Contrast Cine-MRI
title_sort is high temporal resolution achievable for paediatric cardiac acquisitions during several heart beats? illustration with cardiac phase contrast cine-mri
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4658039/
https://www.ncbi.nlm.nih.gov/pubmed/26599755
http://dx.doi.org/10.1371/journal.pone.0143744
work_keys_str_mv AT bonnemainslaurent ishightemporalresolutionachievableforpaediatriccardiacacquisitionsduringseveralheartbeatsillustrationwithcardiacphasecontrastcinemri
AT odillefreddy ishightemporalresolutionachievableforpaediatriccardiacacquisitionsduringseveralheartbeatsillustrationwithcardiacphasecontrastcinemri
AT meyerchristophe ishightemporalresolutionachievableforpaediatriccardiacacquisitionsduringseveralheartbeatsillustrationwithcardiacphasecontrastcinemri
AT hossugabriella ishightemporalresolutionachievableforpaediatriccardiacacquisitionsduringseveralheartbeatsillustrationwithcardiacphasecontrastcinemri
AT felblingerjacques ishightemporalresolutionachievableforpaediatriccardiacacquisitionsduringseveralheartbeatsillustrationwithcardiacphasecontrastcinemri
AT vuissozpierreandre ishightemporalresolutionachievableforpaediatriccardiacacquisitionsduringseveralheartbeatsillustrationwithcardiacphasecontrastcinemri