Cargando…
The Repeatability Assessment of Three-Dimensional Capsule-Intraocular Lens Complex Measurements by Means of High-Speed Swept-Source Optical Coherence Tomography
PURPOSE: To rebuild the three-dimensional (3-D) model of the anterior segment by high-speed swept-source optical coherence tomography (SSOCT) and evaluate the repeatability of measurement for the parameters of capsule-intraocular lens (C-IOL) complex. METHODS: Twenty-two pseudophakic eyes from 22 pa...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4658094/ https://www.ncbi.nlm.nih.gov/pubmed/26600254 http://dx.doi.org/10.1371/journal.pone.0142556 |
_version_ | 1782402474510909440 |
---|---|
author | Ding, Xixia Wang, Qinmei Chang, Pingjun Li, Jin Savini, Giacomo Huang, Jinhai Huang, Shenghai Zhao, Yinying Liao, Na Lin, Lei Yu, Xiaoyu Zhao, Yun-e |
author_facet | Ding, Xixia Wang, Qinmei Chang, Pingjun Li, Jin Savini, Giacomo Huang, Jinhai Huang, Shenghai Zhao, Yinying Liao, Na Lin, Lei Yu, Xiaoyu Zhao, Yun-e |
author_sort | Ding, Xixia |
collection | PubMed |
description | PURPOSE: To rebuild the three-dimensional (3-D) model of the anterior segment by high-speed swept-source optical coherence tomography (SSOCT) and evaluate the repeatability of measurement for the parameters of capsule-intraocular lens (C-IOL) complex. METHODS: Twenty-two pseudophakic eyes from 22 patients were enrolled. Three continuous SSOCT measurements were performed in all eyes and the tomograms obtained were used for 3-D reconstruction. The output data were used to evaluate the measurement repeatability. The parameters included postoperative aqueous depth (PAD), the area and diameter of the anterior capsule opening (Area and D), IOL tilt (IOL-T), horizontal, vertical, and space decentration of the IOL, anterior capsule opening, and IOL-anterior capsule opening. RESULTS: PAD, IOL-T, Area, D, and all decentration measurements showed high repeatability. Repeated measure analysis showed there was no statistically significant difference among the three continuous measurements (all P > .05). Pearson correlation analysis showed high correlation between each pair of them (all r >0.90, P<0.001). ICCs were all more than 0.9 for all parameters. The 95% LoAs of all parameters were narrow for comparison of three measurements, which showed high repeatability for three measurements. CONCLUSION: SSOCT is available to be a new method for the 3-D measurement of C-IOL complex after cataract surgery. This method presented high repeatability in measuring the parameters of the C-IOL complex. |
format | Online Article Text |
id | pubmed-4658094 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-46580942015-12-02 The Repeatability Assessment of Three-Dimensional Capsule-Intraocular Lens Complex Measurements by Means of High-Speed Swept-Source Optical Coherence Tomography Ding, Xixia Wang, Qinmei Chang, Pingjun Li, Jin Savini, Giacomo Huang, Jinhai Huang, Shenghai Zhao, Yinying Liao, Na Lin, Lei Yu, Xiaoyu Zhao, Yun-e PLoS One Research Article PURPOSE: To rebuild the three-dimensional (3-D) model of the anterior segment by high-speed swept-source optical coherence tomography (SSOCT) and evaluate the repeatability of measurement for the parameters of capsule-intraocular lens (C-IOL) complex. METHODS: Twenty-two pseudophakic eyes from 22 patients were enrolled. Three continuous SSOCT measurements were performed in all eyes and the tomograms obtained were used for 3-D reconstruction. The output data were used to evaluate the measurement repeatability. The parameters included postoperative aqueous depth (PAD), the area and diameter of the anterior capsule opening (Area and D), IOL tilt (IOL-T), horizontal, vertical, and space decentration of the IOL, anterior capsule opening, and IOL-anterior capsule opening. RESULTS: PAD, IOL-T, Area, D, and all decentration measurements showed high repeatability. Repeated measure analysis showed there was no statistically significant difference among the three continuous measurements (all P > .05). Pearson correlation analysis showed high correlation between each pair of them (all r >0.90, P<0.001). ICCs were all more than 0.9 for all parameters. The 95% LoAs of all parameters were narrow for comparison of three measurements, which showed high repeatability for three measurements. CONCLUSION: SSOCT is available to be a new method for the 3-D measurement of C-IOL complex after cataract surgery. This method presented high repeatability in measuring the parameters of the C-IOL complex. Public Library of Science 2015-11-23 /pmc/articles/PMC4658094/ /pubmed/26600254 http://dx.doi.org/10.1371/journal.pone.0142556 Text en © 2015 Ding et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Ding, Xixia Wang, Qinmei Chang, Pingjun Li, Jin Savini, Giacomo Huang, Jinhai Huang, Shenghai Zhao, Yinying Liao, Na Lin, Lei Yu, Xiaoyu Zhao, Yun-e The Repeatability Assessment of Three-Dimensional Capsule-Intraocular Lens Complex Measurements by Means of High-Speed Swept-Source Optical Coherence Tomography |
title | The Repeatability Assessment of Three-Dimensional Capsule-Intraocular Lens Complex Measurements by Means of High-Speed Swept-Source Optical Coherence Tomography |
title_full | The Repeatability Assessment of Three-Dimensional Capsule-Intraocular Lens Complex Measurements by Means of High-Speed Swept-Source Optical Coherence Tomography |
title_fullStr | The Repeatability Assessment of Three-Dimensional Capsule-Intraocular Lens Complex Measurements by Means of High-Speed Swept-Source Optical Coherence Tomography |
title_full_unstemmed | The Repeatability Assessment of Three-Dimensional Capsule-Intraocular Lens Complex Measurements by Means of High-Speed Swept-Source Optical Coherence Tomography |
title_short | The Repeatability Assessment of Three-Dimensional Capsule-Intraocular Lens Complex Measurements by Means of High-Speed Swept-Source Optical Coherence Tomography |
title_sort | repeatability assessment of three-dimensional capsule-intraocular lens complex measurements by means of high-speed swept-source optical coherence tomography |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4658094/ https://www.ncbi.nlm.nih.gov/pubmed/26600254 http://dx.doi.org/10.1371/journal.pone.0142556 |
work_keys_str_mv | AT dingxixia therepeatabilityassessmentofthreedimensionalcapsuleintraocularlenscomplexmeasurementsbymeansofhighspeedsweptsourceopticalcoherencetomography AT wangqinmei therepeatabilityassessmentofthreedimensionalcapsuleintraocularlenscomplexmeasurementsbymeansofhighspeedsweptsourceopticalcoherencetomography AT changpingjun therepeatabilityassessmentofthreedimensionalcapsuleintraocularlenscomplexmeasurementsbymeansofhighspeedsweptsourceopticalcoherencetomography AT lijin therepeatabilityassessmentofthreedimensionalcapsuleintraocularlenscomplexmeasurementsbymeansofhighspeedsweptsourceopticalcoherencetomography AT savinigiacomo therepeatabilityassessmentofthreedimensionalcapsuleintraocularlenscomplexmeasurementsbymeansofhighspeedsweptsourceopticalcoherencetomography AT huangjinhai therepeatabilityassessmentofthreedimensionalcapsuleintraocularlenscomplexmeasurementsbymeansofhighspeedsweptsourceopticalcoherencetomography AT huangshenghai therepeatabilityassessmentofthreedimensionalcapsuleintraocularlenscomplexmeasurementsbymeansofhighspeedsweptsourceopticalcoherencetomography AT zhaoyinying therepeatabilityassessmentofthreedimensionalcapsuleintraocularlenscomplexmeasurementsbymeansofhighspeedsweptsourceopticalcoherencetomography AT liaona therepeatabilityassessmentofthreedimensionalcapsuleintraocularlenscomplexmeasurementsbymeansofhighspeedsweptsourceopticalcoherencetomography AT linlei therepeatabilityassessmentofthreedimensionalcapsuleintraocularlenscomplexmeasurementsbymeansofhighspeedsweptsourceopticalcoherencetomography AT yuxiaoyu therepeatabilityassessmentofthreedimensionalcapsuleintraocularlenscomplexmeasurementsbymeansofhighspeedsweptsourceopticalcoherencetomography AT zhaoyune therepeatabilityassessmentofthreedimensionalcapsuleintraocularlenscomplexmeasurementsbymeansofhighspeedsweptsourceopticalcoherencetomography AT dingxixia repeatabilityassessmentofthreedimensionalcapsuleintraocularlenscomplexmeasurementsbymeansofhighspeedsweptsourceopticalcoherencetomography AT wangqinmei repeatabilityassessmentofthreedimensionalcapsuleintraocularlenscomplexmeasurementsbymeansofhighspeedsweptsourceopticalcoherencetomography AT changpingjun repeatabilityassessmentofthreedimensionalcapsuleintraocularlenscomplexmeasurementsbymeansofhighspeedsweptsourceopticalcoherencetomography AT lijin repeatabilityassessmentofthreedimensionalcapsuleintraocularlenscomplexmeasurementsbymeansofhighspeedsweptsourceopticalcoherencetomography AT savinigiacomo repeatabilityassessmentofthreedimensionalcapsuleintraocularlenscomplexmeasurementsbymeansofhighspeedsweptsourceopticalcoherencetomography AT huangjinhai repeatabilityassessmentofthreedimensionalcapsuleintraocularlenscomplexmeasurementsbymeansofhighspeedsweptsourceopticalcoherencetomography AT huangshenghai repeatabilityassessmentofthreedimensionalcapsuleintraocularlenscomplexmeasurementsbymeansofhighspeedsweptsourceopticalcoherencetomography AT zhaoyinying repeatabilityassessmentofthreedimensionalcapsuleintraocularlenscomplexmeasurementsbymeansofhighspeedsweptsourceopticalcoherencetomography AT liaona repeatabilityassessmentofthreedimensionalcapsuleintraocularlenscomplexmeasurementsbymeansofhighspeedsweptsourceopticalcoherencetomography AT linlei repeatabilityassessmentofthreedimensionalcapsuleintraocularlenscomplexmeasurementsbymeansofhighspeedsweptsourceopticalcoherencetomography AT yuxiaoyu repeatabilityassessmentofthreedimensionalcapsuleintraocularlenscomplexmeasurementsbymeansofhighspeedsweptsourceopticalcoherencetomography AT zhaoyune repeatabilityassessmentofthreedimensionalcapsuleintraocularlenscomplexmeasurementsbymeansofhighspeedsweptsourceopticalcoherencetomography |