Technical-Induced Hemolysis in Patients with Respiratory Failure Supported with Veno-Venous ECMO – Prevalence and Risk Factors

The aim of the study was to explore the prevalence and risk factors for technical-induced hemolysis in adults supported with veno-venous extracorporeal membrane oxygenation (vvECMO) and to analyze the effect of hemolytic episodes on outcome. This was a retrospective, single-center study that include...

Descripción completa

Detalles Bibliográficos
Autores principales: Lehle, Karla, Philipp, Alois, Zeman, Florian, Lunz, Dirk, Lubnow, Matthias, Wendel, Hans-Peter, Göbölös, Laszlo, Schmid, Christof, Müller, Thomas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4659553/
https://www.ncbi.nlm.nih.gov/pubmed/26606144
http://dx.doi.org/10.1371/journal.pone.0143527
_version_ 1782402638743076864
author Lehle, Karla
Philipp, Alois
Zeman, Florian
Lunz, Dirk
Lubnow, Matthias
Wendel, Hans-Peter
Göbölös, Laszlo
Schmid, Christof
Müller, Thomas
author_facet Lehle, Karla
Philipp, Alois
Zeman, Florian
Lunz, Dirk
Lubnow, Matthias
Wendel, Hans-Peter
Göbölös, Laszlo
Schmid, Christof
Müller, Thomas
author_sort Lehle, Karla
collection PubMed
description The aim of the study was to explore the prevalence and risk factors for technical-induced hemolysis in adults supported with veno-venous extracorporeal membrane oxygenation (vvECMO) and to analyze the effect of hemolytic episodes on outcome. This was a retrospective, single-center study that included 318 adult patients (Regensburg ECMO Registry, 2009–2014) with acute respiratory failure treated with different modern miniaturized ECMO systems. Free plasma hemoglobin (fHb) was used as indicator for hemolysis. Throughout a cumulative support duration of 4,142 days on ECMO only 1.7% of the fHb levels were above a critical value of 500 mg/l. A grave rise in fHb indicated pumphead thrombosis (n = 8), while acute oxygenator thrombosis (n = 15) did not affect fHb. Replacement of the pumphead normalized fHb within two days. Neither pump or cannula type nor duration on the first system was associated with hemolysis. Multiple trauma, need for kidney replacement therapy, increased daily red blood cell transfusion requirements, and high blood flow (3.0–4.5 L/min) through small-sized cannulas significantly resulted in augmented blood cell trauma. Survivors were characterized by lower peak levels of fHb [90 (60, 142) mg/l] in comparison to non-survivors [148 (91, 256) mg/l, p≤0.001]. In conclusion, marked hemolysis is not common in vvECMO with modern devices. Clinically obvious hemolysis often is caused by pumphead thrombosis. High flow velocity through small cannulas may also cause technical-induced hemolysis. In patients who developed lung failure due to trauma, fHb was elevated independantly of ECMO. In our cohort, the occurance of hemolysis was associated with increased mortality.
format Online
Article
Text
id pubmed-4659553
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-46595532015-12-02 Technical-Induced Hemolysis in Patients with Respiratory Failure Supported with Veno-Venous ECMO – Prevalence and Risk Factors Lehle, Karla Philipp, Alois Zeman, Florian Lunz, Dirk Lubnow, Matthias Wendel, Hans-Peter Göbölös, Laszlo Schmid, Christof Müller, Thomas PLoS One Research Article The aim of the study was to explore the prevalence and risk factors for technical-induced hemolysis in adults supported with veno-venous extracorporeal membrane oxygenation (vvECMO) and to analyze the effect of hemolytic episodes on outcome. This was a retrospective, single-center study that included 318 adult patients (Regensburg ECMO Registry, 2009–2014) with acute respiratory failure treated with different modern miniaturized ECMO systems. Free plasma hemoglobin (fHb) was used as indicator for hemolysis. Throughout a cumulative support duration of 4,142 days on ECMO only 1.7% of the fHb levels were above a critical value of 500 mg/l. A grave rise in fHb indicated pumphead thrombosis (n = 8), while acute oxygenator thrombosis (n = 15) did not affect fHb. Replacement of the pumphead normalized fHb within two days. Neither pump or cannula type nor duration on the first system was associated with hemolysis. Multiple trauma, need for kidney replacement therapy, increased daily red blood cell transfusion requirements, and high blood flow (3.0–4.5 L/min) through small-sized cannulas significantly resulted in augmented blood cell trauma. Survivors were characterized by lower peak levels of fHb [90 (60, 142) mg/l] in comparison to non-survivors [148 (91, 256) mg/l, p≤0.001]. In conclusion, marked hemolysis is not common in vvECMO with modern devices. Clinically obvious hemolysis often is caused by pumphead thrombosis. High flow velocity through small cannulas may also cause technical-induced hemolysis. In patients who developed lung failure due to trauma, fHb was elevated independantly of ECMO. In our cohort, the occurance of hemolysis was associated with increased mortality. Public Library of Science 2015-11-25 /pmc/articles/PMC4659553/ /pubmed/26606144 http://dx.doi.org/10.1371/journal.pone.0143527 Text en © 2015 Lehle et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Lehle, Karla
Philipp, Alois
Zeman, Florian
Lunz, Dirk
Lubnow, Matthias
Wendel, Hans-Peter
Göbölös, Laszlo
Schmid, Christof
Müller, Thomas
Technical-Induced Hemolysis in Patients with Respiratory Failure Supported with Veno-Venous ECMO – Prevalence and Risk Factors
title Technical-Induced Hemolysis in Patients with Respiratory Failure Supported with Veno-Venous ECMO – Prevalence and Risk Factors
title_full Technical-Induced Hemolysis in Patients with Respiratory Failure Supported with Veno-Venous ECMO – Prevalence and Risk Factors
title_fullStr Technical-Induced Hemolysis in Patients with Respiratory Failure Supported with Veno-Venous ECMO – Prevalence and Risk Factors
title_full_unstemmed Technical-Induced Hemolysis in Patients with Respiratory Failure Supported with Veno-Venous ECMO – Prevalence and Risk Factors
title_short Technical-Induced Hemolysis in Patients with Respiratory Failure Supported with Veno-Venous ECMO – Prevalence and Risk Factors
title_sort technical-induced hemolysis in patients with respiratory failure supported with veno-venous ecmo – prevalence and risk factors
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4659553/
https://www.ncbi.nlm.nih.gov/pubmed/26606144
http://dx.doi.org/10.1371/journal.pone.0143527
work_keys_str_mv AT lehlekarla technicalinducedhemolysisinpatientswithrespiratoryfailuresupportedwithvenovenousecmoprevalenceandriskfactors
AT philippalois technicalinducedhemolysisinpatientswithrespiratoryfailuresupportedwithvenovenousecmoprevalenceandriskfactors
AT zemanflorian technicalinducedhemolysisinpatientswithrespiratoryfailuresupportedwithvenovenousecmoprevalenceandriskfactors
AT lunzdirk technicalinducedhemolysisinpatientswithrespiratoryfailuresupportedwithvenovenousecmoprevalenceandriskfactors
AT lubnowmatthias technicalinducedhemolysisinpatientswithrespiratoryfailuresupportedwithvenovenousecmoprevalenceandriskfactors
AT wendelhanspeter technicalinducedhemolysisinpatientswithrespiratoryfailuresupportedwithvenovenousecmoprevalenceandriskfactors
AT goboloslaszlo technicalinducedhemolysisinpatientswithrespiratoryfailuresupportedwithvenovenousecmoprevalenceandriskfactors
AT schmidchristof technicalinducedhemolysisinpatientswithrespiratoryfailuresupportedwithvenovenousecmoprevalenceandriskfactors
AT mullerthomas technicalinducedhemolysisinpatientswithrespiratoryfailuresupportedwithvenovenousecmoprevalenceandriskfactors