Cargando…
Developments in FTICR-MS and Its Potential for Body Fluid Signatures
Fourier transform mass spectrometry (FTMS) is the method of choice for measurements that require ultra-high resolution. The establishment of Fourier transform ion cyclotron resonance (FTICR) MS, the availability of biomolecular ionization techniques and the introduction of the Orbitrap™ mass spectro...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4661870/ https://www.ncbi.nlm.nih.gov/pubmed/26580595 http://dx.doi.org/10.3390/ijms161126012 |
_version_ | 1782403064683036672 |
---|---|
author | Nicolardi, Simone Bogdanov, Bogdan Deelder, André M. Palmblad, Magnus van der Burgt, Yuri E. M. |
author_facet | Nicolardi, Simone Bogdanov, Bogdan Deelder, André M. Palmblad, Magnus van der Burgt, Yuri E. M. |
author_sort | Nicolardi, Simone |
collection | PubMed |
description | Fourier transform mass spectrometry (FTMS) is the method of choice for measurements that require ultra-high resolution. The establishment of Fourier transform ion cyclotron resonance (FTICR) MS, the availability of biomolecular ionization techniques and the introduction of the Orbitrap™ mass spectrometer have widened the number of FTMS-applications enormously. One recent example involves clinical proteomics using FTICR-MS to discover and validate protein biomarker signatures in body fluids such as serum or plasma. These biological samples are highly complex in terms of the type and number of components, their concentration range, and the structural identity of each species, and thus require extensive sample cleanup and chromatographic separation procedures. Clearly, such an elaborate and multi-step sample preparation process hampers high-throughput analysis of large clinical cohorts. A final MS read-out at ultra-high resolution enables the analysis of a more complex sample and can thus simplify upfront fractionations. To this end, FTICR-MS offers superior ultra-high resolving power with accurate and precise mass-to-charge ratio (m/z) measurement of a high number of peptides and small proteins (up to 20 kDa) at isotopic resolution over a wide mass range, and furthermore includes a wide variety of fragmentation strategies to characterize protein sequence and structure, including post-translational modifications (PTMs). In our laboratory, we have successfully applied FTICR “next-generation” peptide profiles with the purpose of cancer disease classifications. Here we will review a number of developments and innovations in FTICR-MS that have resulted in robust and routine procedures aiming for ultra-high resolution signatures of clinical samples, exemplified with state-of-the-art examples for serum and saliva. |
format | Online Article Text |
id | pubmed-4661870 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-46618702015-12-10 Developments in FTICR-MS and Its Potential for Body Fluid Signatures Nicolardi, Simone Bogdanov, Bogdan Deelder, André M. Palmblad, Magnus van der Burgt, Yuri E. M. Int J Mol Sci Review Fourier transform mass spectrometry (FTMS) is the method of choice for measurements that require ultra-high resolution. The establishment of Fourier transform ion cyclotron resonance (FTICR) MS, the availability of biomolecular ionization techniques and the introduction of the Orbitrap™ mass spectrometer have widened the number of FTMS-applications enormously. One recent example involves clinical proteomics using FTICR-MS to discover and validate protein biomarker signatures in body fluids such as serum or plasma. These biological samples are highly complex in terms of the type and number of components, their concentration range, and the structural identity of each species, and thus require extensive sample cleanup and chromatographic separation procedures. Clearly, such an elaborate and multi-step sample preparation process hampers high-throughput analysis of large clinical cohorts. A final MS read-out at ultra-high resolution enables the analysis of a more complex sample and can thus simplify upfront fractionations. To this end, FTICR-MS offers superior ultra-high resolving power with accurate and precise mass-to-charge ratio (m/z) measurement of a high number of peptides and small proteins (up to 20 kDa) at isotopic resolution over a wide mass range, and furthermore includes a wide variety of fragmentation strategies to characterize protein sequence and structure, including post-translational modifications (PTMs). In our laboratory, we have successfully applied FTICR “next-generation” peptide profiles with the purpose of cancer disease classifications. Here we will review a number of developments and innovations in FTICR-MS that have resulted in robust and routine procedures aiming for ultra-high resolution signatures of clinical samples, exemplified with state-of-the-art examples for serum and saliva. MDPI 2015-11-13 /pmc/articles/PMC4661870/ /pubmed/26580595 http://dx.doi.org/10.3390/ijms161126012 Text en © 2015 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons by Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Review Nicolardi, Simone Bogdanov, Bogdan Deelder, André M. Palmblad, Magnus van der Burgt, Yuri E. M. Developments in FTICR-MS and Its Potential for Body Fluid Signatures |
title | Developments in FTICR-MS and Its Potential for Body Fluid Signatures |
title_full | Developments in FTICR-MS and Its Potential for Body Fluid Signatures |
title_fullStr | Developments in FTICR-MS and Its Potential for Body Fluid Signatures |
title_full_unstemmed | Developments in FTICR-MS and Its Potential for Body Fluid Signatures |
title_short | Developments in FTICR-MS and Its Potential for Body Fluid Signatures |
title_sort | developments in fticr-ms and its potential for body fluid signatures |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4661870/ https://www.ncbi.nlm.nih.gov/pubmed/26580595 http://dx.doi.org/10.3390/ijms161126012 |
work_keys_str_mv | AT nicolardisimone developmentsinfticrmsanditspotentialforbodyfluidsignatures AT bogdanovbogdan developmentsinfticrmsanditspotentialforbodyfluidsignatures AT deelderandrem developmentsinfticrmsanditspotentialforbodyfluidsignatures AT palmbladmagnus developmentsinfticrmsanditspotentialforbodyfluidsignatures AT vanderburgtyuriem developmentsinfticrmsanditspotentialforbodyfluidsignatures |