Cargando…

Parallel simulations for QUAntifying RElaxation magnetic resonance constants (SQUAREMR): an example towards accurate MOLLI T1 measurements

BACKGROUND: T1 mapping is widely used today in CMR, however, it underestimates true T1 values and its measurement error is influenced by several acquisition parameters. The purpose of this study was the extraction of accurate T1 data through the utilization of comprehensive, parallel Simulations for...

Descripción completa

Detalles Bibliográficos
Autores principales: Xanthis, Christos G., Bidhult, Sebastian, Kantasis, George, Heiberg, Einar, Arheden, Håkan, Aletras, Anthony H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4662017/
https://www.ncbi.nlm.nih.gov/pubmed/26610703
http://dx.doi.org/10.1186/s12968-015-0206-1
_version_ 1782403097888292864
author Xanthis, Christos G.
Bidhult, Sebastian
Kantasis, George
Heiberg, Einar
Arheden, Håkan
Aletras, Anthony H.
author_facet Xanthis, Christos G.
Bidhult, Sebastian
Kantasis, George
Heiberg, Einar
Arheden, Håkan
Aletras, Anthony H.
author_sort Xanthis, Christos G.
collection PubMed
description BACKGROUND: T1 mapping is widely used today in CMR, however, it underestimates true T1 values and its measurement error is influenced by several acquisition parameters. The purpose of this study was the extraction of accurate T1 data through the utilization of comprehensive, parallel Simulations for QUAntifying RElaxation Magnetic Resonance constants (SQUAREMR) of the MOLLI pulse sequence on a large population of spins with physiologically relevant tissue relaxation constants. METHODS: A CMR protocol consisting of different MOLLI schemes was performed on phantoms and healthy human volunteers. For every MOLLI experiment, the identical pulse sequence was simulated for a large range of physiological combinations of relaxation constants, resulting in a database of all possible outcomes. The unknown relaxation constants were then determined by finding the simulated signals in the database that produced the least squared difference to the measured signal intensities. RESULTS: SQUAREMR demonstrated improvement of accuracy in phantom studies and consistent mean T1 values and consistent variance across the different MOLLI schemes in humans. This was true even for tissues with long T1s and MOLLI schemes with no pause between modified-Look-Locker experiments. CONCLUSIONS: SQUAREMR enables quantification of T1 data obtained by existing clinical pulse sequences. SQUAREMR allows for correction of quantitative CMR data that have already been acquired whereas it is expected that SQUAREMR may improve data consistency and advance quantitative MR across imaging centers, vendors and experimental configurations. While this study is focused on a MOLLI-based T1-mapping technique, it could however be extended in other types of quantitative MRI throughout the body.
format Online
Article
Text
id pubmed-4662017
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-46620172015-12-02 Parallel simulations for QUAntifying RElaxation magnetic resonance constants (SQUAREMR): an example towards accurate MOLLI T1 measurements Xanthis, Christos G. Bidhult, Sebastian Kantasis, George Heiberg, Einar Arheden, Håkan Aletras, Anthony H. J Cardiovasc Magn Reson Research BACKGROUND: T1 mapping is widely used today in CMR, however, it underestimates true T1 values and its measurement error is influenced by several acquisition parameters. The purpose of this study was the extraction of accurate T1 data through the utilization of comprehensive, parallel Simulations for QUAntifying RElaxation Magnetic Resonance constants (SQUAREMR) of the MOLLI pulse sequence on a large population of spins with physiologically relevant tissue relaxation constants. METHODS: A CMR protocol consisting of different MOLLI schemes was performed on phantoms and healthy human volunteers. For every MOLLI experiment, the identical pulse sequence was simulated for a large range of physiological combinations of relaxation constants, resulting in a database of all possible outcomes. The unknown relaxation constants were then determined by finding the simulated signals in the database that produced the least squared difference to the measured signal intensities. RESULTS: SQUAREMR demonstrated improvement of accuracy in phantom studies and consistent mean T1 values and consistent variance across the different MOLLI schemes in humans. This was true even for tissues with long T1s and MOLLI schemes with no pause between modified-Look-Locker experiments. CONCLUSIONS: SQUAREMR enables quantification of T1 data obtained by existing clinical pulse sequences. SQUAREMR allows for correction of quantitative CMR data that have already been acquired whereas it is expected that SQUAREMR may improve data consistency and advance quantitative MR across imaging centers, vendors and experimental configurations. While this study is focused on a MOLLI-based T1-mapping technique, it could however be extended in other types of quantitative MRI throughout the body. BioMed Central 2015-11-26 /pmc/articles/PMC4662017/ /pubmed/26610703 http://dx.doi.org/10.1186/s12968-015-0206-1 Text en © Xanthis et al. 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Xanthis, Christos G.
Bidhult, Sebastian
Kantasis, George
Heiberg, Einar
Arheden, Håkan
Aletras, Anthony H.
Parallel simulations for QUAntifying RElaxation magnetic resonance constants (SQUAREMR): an example towards accurate MOLLI T1 measurements
title Parallel simulations for QUAntifying RElaxation magnetic resonance constants (SQUAREMR): an example towards accurate MOLLI T1 measurements
title_full Parallel simulations for QUAntifying RElaxation magnetic resonance constants (SQUAREMR): an example towards accurate MOLLI T1 measurements
title_fullStr Parallel simulations for QUAntifying RElaxation magnetic resonance constants (SQUAREMR): an example towards accurate MOLLI T1 measurements
title_full_unstemmed Parallel simulations for QUAntifying RElaxation magnetic resonance constants (SQUAREMR): an example towards accurate MOLLI T1 measurements
title_short Parallel simulations for QUAntifying RElaxation magnetic resonance constants (SQUAREMR): an example towards accurate MOLLI T1 measurements
title_sort parallel simulations for quantifying relaxation magnetic resonance constants (squaremr): an example towards accurate molli t1 measurements
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4662017/
https://www.ncbi.nlm.nih.gov/pubmed/26610703
http://dx.doi.org/10.1186/s12968-015-0206-1
work_keys_str_mv AT xanthischristosg parallelsimulationsforquantifyingrelaxationmagneticresonanceconstantssquaremranexampletowardsaccuratemollit1measurements
AT bidhultsebastian parallelsimulationsforquantifyingrelaxationmagneticresonanceconstantssquaremranexampletowardsaccuratemollit1measurements
AT kantasisgeorge parallelsimulationsforquantifyingrelaxationmagneticresonanceconstantssquaremranexampletowardsaccuratemollit1measurements
AT heibergeinar parallelsimulationsforquantifyingrelaxationmagneticresonanceconstantssquaremranexampletowardsaccuratemollit1measurements
AT arhedenhakan parallelsimulationsforquantifyingrelaxationmagneticresonanceconstantssquaremranexampletowardsaccuratemollit1measurements
AT aletrasanthonyh parallelsimulationsforquantifyingrelaxationmagneticresonanceconstantssquaremranexampletowardsaccuratemollit1measurements