Cargando…
HTRF: a technology tailored for biomarker determination—novel analytical detection system suitable for detection of specific autoimmune antibodies as biomarkers in nanogram level in different body fluids
BACKGROUND: Classical methods of gene product analysis such as binding assays (e.g., ELISA, protein chip technology) are generally time-consuming, lab-intensive, less sensitive, and lack high-throughput capacity. In addition, all existing methods used to measure proteins necessitate multiple divisio...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4662825/ https://www.ncbi.nlm.nih.gov/pubmed/26617680 http://dx.doi.org/10.1186/s13167-015-0046-y |
_version_ | 1782403213682540544 |
---|---|
author | Einhorn, Lukas Krapfenbauer, Kurt |
author_facet | Einhorn, Lukas Krapfenbauer, Kurt |
author_sort | Einhorn, Lukas |
collection | PubMed |
description | BACKGROUND: Classical methods of gene product analysis such as binding assays (e.g., ELISA, protein chip technology) are generally time-consuming, lab-intensive, less sensitive, and lack high-throughput capacity. In addition, all existing methods used to measure proteins necessitate multiple divisions of the original sample and individual tests carried out for each substance, with an associated cost for each test. METHOD: Together with a small biotech company, we developed a new and innovative analytical detection system based on homogenous time-resolved fluorescence (HTRF) technology. Our system facilitates the development of immune assays that measure selective different analytes such as selected biomarkers in a small sample volume at less than 20 min with a much higher sensitivity compared to common binding assay systems such as enzyme-linked immunosorbent assay (ELISA). Recent advances of the application of this novel detection system combine the power of miniaturization, microfluidics, better linear range, and faster quantification. RESULTS: The power of the HTRF technology offers great promise for point-of-care clinical testing and monitoring of many important analytes such as disease-specific biomarkers in the nanogram level in different human body fluids such as CSF, blood, serum, plasma, and saliva. The linear dynamical range of our HTRF assay was determined between 2.5 and 100 ng/mL. Precision and accuracy calculated for inter- as well as intra-assays was less than ± 10 %. Intra-assay and inter-assay precision for high, medium, and low analyte concentrations show mean CV values less than ± 10 %. Intra- and inter-assay accuracy for all three concentrations show mean recovery values of 80–120 %. CONCLUSION: The aim of this work is to describe the development and establishment of this novel HTRF system that allows the very fast detection and quantification of biomarkers in different human body fluids. Furthermore, a specific antibody combination that assures a specific binding of the correct refolded autoimmune IgG is evaluated. |
format | Online Article Text |
id | pubmed-4662825 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-46628252015-11-29 HTRF: a technology tailored for biomarker determination—novel analytical detection system suitable for detection of specific autoimmune antibodies as biomarkers in nanogram level in different body fluids Einhorn, Lukas Krapfenbauer, Kurt EPMA J Research BACKGROUND: Classical methods of gene product analysis such as binding assays (e.g., ELISA, protein chip technology) are generally time-consuming, lab-intensive, less sensitive, and lack high-throughput capacity. In addition, all existing methods used to measure proteins necessitate multiple divisions of the original sample and individual tests carried out for each substance, with an associated cost for each test. METHOD: Together with a small biotech company, we developed a new and innovative analytical detection system based on homogenous time-resolved fluorescence (HTRF) technology. Our system facilitates the development of immune assays that measure selective different analytes such as selected biomarkers in a small sample volume at less than 20 min with a much higher sensitivity compared to common binding assay systems such as enzyme-linked immunosorbent assay (ELISA). Recent advances of the application of this novel detection system combine the power of miniaturization, microfluidics, better linear range, and faster quantification. RESULTS: The power of the HTRF technology offers great promise for point-of-care clinical testing and monitoring of many important analytes such as disease-specific biomarkers in the nanogram level in different human body fluids such as CSF, blood, serum, plasma, and saliva. The linear dynamical range of our HTRF assay was determined between 2.5 and 100 ng/mL. Precision and accuracy calculated for inter- as well as intra-assays was less than ± 10 %. Intra-assay and inter-assay precision for high, medium, and low analyte concentrations show mean CV values less than ± 10 %. Intra- and inter-assay accuracy for all three concentrations show mean recovery values of 80–120 %. CONCLUSION: The aim of this work is to describe the development and establishment of this novel HTRF system that allows the very fast detection and quantification of biomarkers in different human body fluids. Furthermore, a specific antibody combination that assures a specific binding of the correct refolded autoimmune IgG is evaluated. BioMed Central 2015-11-27 /pmc/articles/PMC4662825/ /pubmed/26617680 http://dx.doi.org/10.1186/s13167-015-0046-y Text en © Einhorn and Krapfenbauer. 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Einhorn, Lukas Krapfenbauer, Kurt HTRF: a technology tailored for biomarker determination—novel analytical detection system suitable for detection of specific autoimmune antibodies as biomarkers in nanogram level in different body fluids |
title | HTRF: a technology tailored for biomarker determination—novel analytical detection system suitable for detection of specific autoimmune antibodies as biomarkers in nanogram level in different body fluids |
title_full | HTRF: a technology tailored for biomarker determination—novel analytical detection system suitable for detection of specific autoimmune antibodies as biomarkers in nanogram level in different body fluids |
title_fullStr | HTRF: a technology tailored for biomarker determination—novel analytical detection system suitable for detection of specific autoimmune antibodies as biomarkers in nanogram level in different body fluids |
title_full_unstemmed | HTRF: a technology tailored for biomarker determination—novel analytical detection system suitable for detection of specific autoimmune antibodies as biomarkers in nanogram level in different body fluids |
title_short | HTRF: a technology tailored for biomarker determination—novel analytical detection system suitable for detection of specific autoimmune antibodies as biomarkers in nanogram level in different body fluids |
title_sort | htrf: a technology tailored for biomarker determination—novel analytical detection system suitable for detection of specific autoimmune antibodies as biomarkers in nanogram level in different body fluids |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4662825/ https://www.ncbi.nlm.nih.gov/pubmed/26617680 http://dx.doi.org/10.1186/s13167-015-0046-y |
work_keys_str_mv | AT einhornlukas htrfatechnologytailoredforbiomarkerdeterminationnovelanalyticaldetectionsystemsuitablefordetectionofspecificautoimmuneantibodiesasbiomarkersinnanogramlevelindifferentbodyfluids AT krapfenbauerkurt htrfatechnologytailoredforbiomarkerdeterminationnovelanalyticaldetectionsystemsuitablefordetectionofspecificautoimmuneantibodiesasbiomarkersinnanogramlevelindifferentbodyfluids |