Cargando…
The Effects of Different Miniscrew Thread Designs and Force Directions on Stress Distribution by 3-dimensional Finite Element Analysis
STATEMENT OF THE PROBLEM: The use of miniscrew as an absolute anchorage device in clinical orthodontics is growing increasingly. Many attempts have been made to reduce the size, to improve the design, and to increase the stability of miniscrew. PURPOSE: The purpose of this study was to determine the...
Autores principales: | Fattahi, Hamidreza, Ajami, Shabnam, Nabavizadeh Rafsanjani, Ali |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Shiraz University of Medical Sciences
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4664032/ https://www.ncbi.nlm.nih.gov/pubmed/26636123 |
Ejemplares similares
-
Stress distributions of a bracket type orthodontic miniscrew and the surrounding bone under moment loadings: Three-dimensional finite element analysis
por: Ajami, Shabnam, et al.
Publicado: (2016) -
Thread shape, cortical bone thickness, and magnitude and distribution of stress caused by the loading of orthodontic miniscrews: finite element analysis
por: Sakamaki, Takuma, et al.
Publicado: (2022) -
Influence of three different implant thread designs on stress distribution: A three-dimensional finite element analysis
por: Oswal, Mansi Manish, et al.
Publicado: (2016) -
Assessing the Effect of Dental Implants Thread Design on Distribution of Stress in Impact Loadings Using Three Dimensional Finite Element Method
por: I, Zarei, et al.
Publicado: (2016) -
Three-dimensional optimization and sensitivity analysis of dental implant thread parameters using finite element analysis
por: Geramizadeh, Maryam, et al.
Publicado: (2018)