Cargando…

Dosimetric impact of different CT datasets for stereotactic treatment planning using 3D conformal radiotherapy or volumetric modulated arc therapy

BACKGROUND: The purpose of this study was to assess the impact on dose to the planning target volume (PTV) and organs at risk (OAR) by using four differently generated CT datasets for dose calculation in stereotactic body radiotherapy (SBRT) of lung and liver tumors. Additionally, dose differences b...

Descripción completa

Detalles Bibliográficos
Autores principales: Oechsner, Markus, Odersky, Leonhard, Berndt, Johannes, Combs, Stephanie Elisabeth, Wilkens, Jan Jakob, Duma, Marciana Nona
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4666088/
https://www.ncbi.nlm.nih.gov/pubmed/26626865
http://dx.doi.org/10.1186/s13014-015-0557-7
_version_ 1782403659899863040
author Oechsner, Markus
Odersky, Leonhard
Berndt, Johannes
Combs, Stephanie Elisabeth
Wilkens, Jan Jakob
Duma, Marciana Nona
author_facet Oechsner, Markus
Odersky, Leonhard
Berndt, Johannes
Combs, Stephanie Elisabeth
Wilkens, Jan Jakob
Duma, Marciana Nona
author_sort Oechsner, Markus
collection PubMed
description BACKGROUND: The purpose of this study was to assess the impact on dose to the planning target volume (PTV) and organs at risk (OAR) by using four differently generated CT datasets for dose calculation in stereotactic body radiotherapy (SBRT) of lung and liver tumors. Additionally, dose differences between 3D conformal radiotherapy and volumetric modulated arc therapy (VMAT) plans calculated on these CT datasets were determined. METHODS: Twenty SBRT patients, ten lung cases and ten liver cases, were retrospectively selected for this study. Treatment plans were optimized on average intensity projection (AIP) CTs using 3D conformal radiotherapy (3D-CRT) and volumetric modulated arc therapy (VMAT). Afterwards, the plans were copied to the planning CTs (PCT), maximum intensity projection (MIP) and mid-ventilation (MidV) CT datasets and dose was recalculated keeping all beam parameters and monitor units unchanged. Ipsilateral lung and liver volumes and dosimetric parameters for PTV (D(mean), D(2), D(98), D(95)), ipsilateral lung and liver (D(mean), V(30), V(20), V(10)) were determined and statistically analysed using Wilcoxon test. RESULTS: Significant but small mean differences were found for PTV dose between the CTs (lung SBRT: ≤2.5 %; liver SBRT: ≤1.6 %). MIPs achieved the smallest lung and the largest liver volumes. OAR mean doses in MIP plans were distinctly smaller than in the other CT datasets. Furthermore, overlapping of tumors with the diaphragm results in underestimated ipsilateral lung dose in MIP plans. Best agreement was found between AIP and MidV (lung SBRT). Overall, differences in liver SBRT were smaller than in lung SBRT and VMAT plans achieved slightly smaller differences than 3D-CRT plans. CONCLUSIONS: Only small differences were found for PTV parameters between the four CT datasets. Larger differences occurred for the doses to organs at risk (ipsilateral lung, liver) especially for MIP plans. No relevant differences were observed between 3D-CRT or VMAT plans. MIP CTs are not appropriate for OAR dose assessment. PCT, AIP and MidV resulted in similar doses. If a 4DCT is acquired PCT can be omitted using AIP or MidV for treatment planning.
format Online
Article
Text
id pubmed-4666088
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-46660882015-12-02 Dosimetric impact of different CT datasets for stereotactic treatment planning using 3D conformal radiotherapy or volumetric modulated arc therapy Oechsner, Markus Odersky, Leonhard Berndt, Johannes Combs, Stephanie Elisabeth Wilkens, Jan Jakob Duma, Marciana Nona Radiat Oncol Research BACKGROUND: The purpose of this study was to assess the impact on dose to the planning target volume (PTV) and organs at risk (OAR) by using four differently generated CT datasets for dose calculation in stereotactic body radiotherapy (SBRT) of lung and liver tumors. Additionally, dose differences between 3D conformal radiotherapy and volumetric modulated arc therapy (VMAT) plans calculated on these CT datasets were determined. METHODS: Twenty SBRT patients, ten lung cases and ten liver cases, were retrospectively selected for this study. Treatment plans were optimized on average intensity projection (AIP) CTs using 3D conformal radiotherapy (3D-CRT) and volumetric modulated arc therapy (VMAT). Afterwards, the plans were copied to the planning CTs (PCT), maximum intensity projection (MIP) and mid-ventilation (MidV) CT datasets and dose was recalculated keeping all beam parameters and monitor units unchanged. Ipsilateral lung and liver volumes and dosimetric parameters for PTV (D(mean), D(2), D(98), D(95)), ipsilateral lung and liver (D(mean), V(30), V(20), V(10)) were determined and statistically analysed using Wilcoxon test. RESULTS: Significant but small mean differences were found for PTV dose between the CTs (lung SBRT: ≤2.5 %; liver SBRT: ≤1.6 %). MIPs achieved the smallest lung and the largest liver volumes. OAR mean doses in MIP plans were distinctly smaller than in the other CT datasets. Furthermore, overlapping of tumors with the diaphragm results in underestimated ipsilateral lung dose in MIP plans. Best agreement was found between AIP and MidV (lung SBRT). Overall, differences in liver SBRT were smaller than in lung SBRT and VMAT plans achieved slightly smaller differences than 3D-CRT plans. CONCLUSIONS: Only small differences were found for PTV parameters between the four CT datasets. Larger differences occurred for the doses to organs at risk (ipsilateral lung, liver) especially for MIP plans. No relevant differences were observed between 3D-CRT or VMAT plans. MIP CTs are not appropriate for OAR dose assessment. PCT, AIP and MidV resulted in similar doses. If a 4DCT is acquired PCT can be omitted using AIP or MidV for treatment planning. BioMed Central 2015-12-01 /pmc/articles/PMC4666088/ /pubmed/26626865 http://dx.doi.org/10.1186/s13014-015-0557-7 Text en © Oechsner et al. 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Oechsner, Markus
Odersky, Leonhard
Berndt, Johannes
Combs, Stephanie Elisabeth
Wilkens, Jan Jakob
Duma, Marciana Nona
Dosimetric impact of different CT datasets for stereotactic treatment planning using 3D conformal radiotherapy or volumetric modulated arc therapy
title Dosimetric impact of different CT datasets for stereotactic treatment planning using 3D conformal radiotherapy or volumetric modulated arc therapy
title_full Dosimetric impact of different CT datasets for stereotactic treatment planning using 3D conformal radiotherapy or volumetric modulated arc therapy
title_fullStr Dosimetric impact of different CT datasets for stereotactic treatment planning using 3D conformal radiotherapy or volumetric modulated arc therapy
title_full_unstemmed Dosimetric impact of different CT datasets for stereotactic treatment planning using 3D conformal radiotherapy or volumetric modulated arc therapy
title_short Dosimetric impact of different CT datasets for stereotactic treatment planning using 3D conformal radiotherapy or volumetric modulated arc therapy
title_sort dosimetric impact of different ct datasets for stereotactic treatment planning using 3d conformal radiotherapy or volumetric modulated arc therapy
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4666088/
https://www.ncbi.nlm.nih.gov/pubmed/26626865
http://dx.doi.org/10.1186/s13014-015-0557-7
work_keys_str_mv AT oechsnermarkus dosimetricimpactofdifferentctdatasetsforstereotactictreatmentplanningusing3dconformalradiotherapyorvolumetricmodulatedarctherapy
AT oderskyleonhard dosimetricimpactofdifferentctdatasetsforstereotactictreatmentplanningusing3dconformalradiotherapyorvolumetricmodulatedarctherapy
AT berndtjohannes dosimetricimpactofdifferentctdatasetsforstereotactictreatmentplanningusing3dconformalradiotherapyorvolumetricmodulatedarctherapy
AT combsstephanieelisabeth dosimetricimpactofdifferentctdatasetsforstereotactictreatmentplanningusing3dconformalradiotherapyorvolumetricmodulatedarctherapy
AT wilkensjanjakob dosimetricimpactofdifferentctdatasetsforstereotactictreatmentplanningusing3dconformalradiotherapyorvolumetricmodulatedarctherapy
AT dumamarciananona dosimetricimpactofdifferentctdatasetsforstereotactictreatmentplanningusing3dconformalradiotherapyorvolumetricmodulatedarctherapy