Cargando…
Clinical Performance of a New Soluble CD14-Subtype Immunochromatographic Test for Whole Blood Compared with Chemiluminescent Enzyme Immunoassay: Use of Quantitative Soluble CD14-Subtype Immunochromatographic Tests for the Diagnosis of Sepsis
We previously reported that a soluble CD14-subtype (sCD14-ST) immunochromatographic test (ICT) for plasma is more convenient than chemiluminescent enzyme immunoassay (CLEIA), but plasma separation makes bedside measurements difficult. We developed a new sCD14-ST ICT for whole blood and investigated...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4666562/ https://www.ncbi.nlm.nih.gov/pubmed/26623644 http://dx.doi.org/10.1371/journal.pone.0143971 |
_version_ | 1782403720213954560 |
---|---|
author | Sato, Masayuki Takahashi, Gaku Shibata, Shigehiro Onodera, Makoto Suzuki, Yasushi Inoue, Yoshihiro Endo, Shigeatsu |
author_facet | Sato, Masayuki Takahashi, Gaku Shibata, Shigehiro Onodera, Makoto Suzuki, Yasushi Inoue, Yoshihiro Endo, Shigeatsu |
author_sort | Sato, Masayuki |
collection | PubMed |
description | We previously reported that a soluble CD14-subtype (sCD14-ST) immunochromatographic test (ICT) for plasma is more convenient than chemiluminescent enzyme immunoassay (CLEIA), but plasma separation makes bedside measurements difficult. We developed a new sCD14-ST ICT for whole blood and investigated whether quantitative determinations of sCD14-ST by ICT were useful for diagnosing sepsis and severe sepsis/septic shock. We studied 20 patients who fulfilled two or more systemic inflammatory response syndrome (SIRS) criteria and 32 patients who had been diagnosed with sepsis or severe sepsis/septic shock. Whole blood was collected on day 0 (on admission) and day 7, and the sCD14-ST concentration was quantitatively measured by CLEIA and ICT for whole blood. The patients’ Acute Physiology and Chronic Health Evaluation (APACHE) II, Sequential Organ Failure Assessment (SOFA), and Mortality in Emergency Department Sepsis (MEDS) scores were also calculated. The cut-off values obtained by the quantitative measurements made by ICT were 464.5 pg/mL for sepsis and 762.7 pg/mL for severe sepsis/septic shock (P < 0.0001). A Bland–Altman plot showed that no fixed bias or proportional bias was detected between CLEIA and quantitative ICT for whole blood. sCD14-ST concentrations were significantly correlated with APACHE II, SOFA, and MEDS scores (P < 0.0001). These results suggest that the new sCD14-ST ICT for whole blood may be a useful tool for the convenient, rapid bedside diagnosis and treatment of sepsis. |
format | Online Article Text |
id | pubmed-4666562 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-46665622015-12-10 Clinical Performance of a New Soluble CD14-Subtype Immunochromatographic Test for Whole Blood Compared with Chemiluminescent Enzyme Immunoassay: Use of Quantitative Soluble CD14-Subtype Immunochromatographic Tests for the Diagnosis of Sepsis Sato, Masayuki Takahashi, Gaku Shibata, Shigehiro Onodera, Makoto Suzuki, Yasushi Inoue, Yoshihiro Endo, Shigeatsu PLoS One Research Article We previously reported that a soluble CD14-subtype (sCD14-ST) immunochromatographic test (ICT) for plasma is more convenient than chemiluminescent enzyme immunoassay (CLEIA), but plasma separation makes bedside measurements difficult. We developed a new sCD14-ST ICT for whole blood and investigated whether quantitative determinations of sCD14-ST by ICT were useful for diagnosing sepsis and severe sepsis/septic shock. We studied 20 patients who fulfilled two or more systemic inflammatory response syndrome (SIRS) criteria and 32 patients who had been diagnosed with sepsis or severe sepsis/septic shock. Whole blood was collected on day 0 (on admission) and day 7, and the sCD14-ST concentration was quantitatively measured by CLEIA and ICT for whole blood. The patients’ Acute Physiology and Chronic Health Evaluation (APACHE) II, Sequential Organ Failure Assessment (SOFA), and Mortality in Emergency Department Sepsis (MEDS) scores were also calculated. The cut-off values obtained by the quantitative measurements made by ICT were 464.5 pg/mL for sepsis and 762.7 pg/mL for severe sepsis/septic shock (P < 0.0001). A Bland–Altman plot showed that no fixed bias or proportional bias was detected between CLEIA and quantitative ICT for whole blood. sCD14-ST concentrations were significantly correlated with APACHE II, SOFA, and MEDS scores (P < 0.0001). These results suggest that the new sCD14-ST ICT for whole blood may be a useful tool for the convenient, rapid bedside diagnosis and treatment of sepsis. Public Library of Science 2015-12-01 /pmc/articles/PMC4666562/ /pubmed/26623644 http://dx.doi.org/10.1371/journal.pone.0143971 Text en © 2015 Sato et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Sato, Masayuki Takahashi, Gaku Shibata, Shigehiro Onodera, Makoto Suzuki, Yasushi Inoue, Yoshihiro Endo, Shigeatsu Clinical Performance of a New Soluble CD14-Subtype Immunochromatographic Test for Whole Blood Compared with Chemiluminescent Enzyme Immunoassay: Use of Quantitative Soluble CD14-Subtype Immunochromatographic Tests for the Diagnosis of Sepsis |
title | Clinical Performance of a New Soluble CD14-Subtype Immunochromatographic Test for Whole Blood Compared with Chemiluminescent Enzyme Immunoassay: Use of Quantitative Soluble CD14-Subtype Immunochromatographic Tests for the Diagnosis of Sepsis |
title_full | Clinical Performance of a New Soluble CD14-Subtype Immunochromatographic Test for Whole Blood Compared with Chemiluminescent Enzyme Immunoassay: Use of Quantitative Soluble CD14-Subtype Immunochromatographic Tests for the Diagnosis of Sepsis |
title_fullStr | Clinical Performance of a New Soluble CD14-Subtype Immunochromatographic Test for Whole Blood Compared with Chemiluminescent Enzyme Immunoassay: Use of Quantitative Soluble CD14-Subtype Immunochromatographic Tests for the Diagnosis of Sepsis |
title_full_unstemmed | Clinical Performance of a New Soluble CD14-Subtype Immunochromatographic Test for Whole Blood Compared with Chemiluminescent Enzyme Immunoassay: Use of Quantitative Soluble CD14-Subtype Immunochromatographic Tests for the Diagnosis of Sepsis |
title_short | Clinical Performance of a New Soluble CD14-Subtype Immunochromatographic Test for Whole Blood Compared with Chemiluminescent Enzyme Immunoassay: Use of Quantitative Soluble CD14-Subtype Immunochromatographic Tests for the Diagnosis of Sepsis |
title_sort | clinical performance of a new soluble cd14-subtype immunochromatographic test for whole blood compared with chemiluminescent enzyme immunoassay: use of quantitative soluble cd14-subtype immunochromatographic tests for the diagnosis of sepsis |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4666562/ https://www.ncbi.nlm.nih.gov/pubmed/26623644 http://dx.doi.org/10.1371/journal.pone.0143971 |
work_keys_str_mv | AT satomasayuki clinicalperformanceofanewsolublecd14subtypeimmunochromatographictestforwholebloodcomparedwithchemiluminescentenzymeimmunoassayuseofquantitativesolublecd14subtypeimmunochromatographictestsforthediagnosisofsepsis AT takahashigaku clinicalperformanceofanewsolublecd14subtypeimmunochromatographictestforwholebloodcomparedwithchemiluminescentenzymeimmunoassayuseofquantitativesolublecd14subtypeimmunochromatographictestsforthediagnosisofsepsis AT shibatashigehiro clinicalperformanceofanewsolublecd14subtypeimmunochromatographictestforwholebloodcomparedwithchemiluminescentenzymeimmunoassayuseofquantitativesolublecd14subtypeimmunochromatographictestsforthediagnosisofsepsis AT onoderamakoto clinicalperformanceofanewsolublecd14subtypeimmunochromatographictestforwholebloodcomparedwithchemiluminescentenzymeimmunoassayuseofquantitativesolublecd14subtypeimmunochromatographictestsforthediagnosisofsepsis AT suzukiyasushi clinicalperformanceofanewsolublecd14subtypeimmunochromatographictestforwholebloodcomparedwithchemiluminescentenzymeimmunoassayuseofquantitativesolublecd14subtypeimmunochromatographictestsforthediagnosisofsepsis AT inoueyoshihiro clinicalperformanceofanewsolublecd14subtypeimmunochromatographictestforwholebloodcomparedwithchemiluminescentenzymeimmunoassayuseofquantitativesolublecd14subtypeimmunochromatographictestsforthediagnosisofsepsis AT endoshigeatsu clinicalperformanceofanewsolublecd14subtypeimmunochromatographictestforwholebloodcomparedwithchemiluminescentenzymeimmunoassayuseofquantitativesolublecd14subtypeimmunochromatographictestsforthediagnosisofsepsis |