Clinical Performance of a New Soluble CD14-Subtype Immunochromatographic Test for Whole Blood Compared with Chemiluminescent Enzyme Immunoassay: Use of Quantitative Soluble CD14-Subtype Immunochromatographic Tests for the Diagnosis of Sepsis

We previously reported that a soluble CD14-subtype (sCD14-ST) immunochromatographic test (ICT) for plasma is more convenient than chemiluminescent enzyme immunoassay (CLEIA), but plasma separation makes bedside measurements difficult. We developed a new sCD14-ST ICT for whole blood and investigated...

Descripción completa

Detalles Bibliográficos
Autores principales: Sato, Masayuki, Takahashi, Gaku, Shibata, Shigehiro, Onodera, Makoto, Suzuki, Yasushi, Inoue, Yoshihiro, Endo, Shigeatsu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4666562/
https://www.ncbi.nlm.nih.gov/pubmed/26623644
http://dx.doi.org/10.1371/journal.pone.0143971
_version_ 1782403720213954560
author Sato, Masayuki
Takahashi, Gaku
Shibata, Shigehiro
Onodera, Makoto
Suzuki, Yasushi
Inoue, Yoshihiro
Endo, Shigeatsu
author_facet Sato, Masayuki
Takahashi, Gaku
Shibata, Shigehiro
Onodera, Makoto
Suzuki, Yasushi
Inoue, Yoshihiro
Endo, Shigeatsu
author_sort Sato, Masayuki
collection PubMed
description We previously reported that a soluble CD14-subtype (sCD14-ST) immunochromatographic test (ICT) for plasma is more convenient than chemiluminescent enzyme immunoassay (CLEIA), but plasma separation makes bedside measurements difficult. We developed a new sCD14-ST ICT for whole blood and investigated whether quantitative determinations of sCD14-ST by ICT were useful for diagnosing sepsis and severe sepsis/septic shock. We studied 20 patients who fulfilled two or more systemic inflammatory response syndrome (SIRS) criteria and 32 patients who had been diagnosed with sepsis or severe sepsis/septic shock. Whole blood was collected on day 0 (on admission) and day 7, and the sCD14-ST concentration was quantitatively measured by CLEIA and ICT for whole blood. The patients’ Acute Physiology and Chronic Health Evaluation (APACHE) II, Sequential Organ Failure Assessment (SOFA), and Mortality in Emergency Department Sepsis (MEDS) scores were also calculated. The cut-off values obtained by the quantitative measurements made by ICT were 464.5 pg/mL for sepsis and 762.7 pg/mL for severe sepsis/septic shock (P < 0.0001). A Bland–Altman plot showed that no fixed bias or proportional bias was detected between CLEIA and quantitative ICT for whole blood. sCD14-ST concentrations were significantly correlated with APACHE II, SOFA, and MEDS scores (P < 0.0001). These results suggest that the new sCD14-ST ICT for whole blood may be a useful tool for the convenient, rapid bedside diagnosis and treatment of sepsis.
format Online
Article
Text
id pubmed-4666562
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-46665622015-12-10 Clinical Performance of a New Soluble CD14-Subtype Immunochromatographic Test for Whole Blood Compared with Chemiluminescent Enzyme Immunoassay: Use of Quantitative Soluble CD14-Subtype Immunochromatographic Tests for the Diagnosis of Sepsis Sato, Masayuki Takahashi, Gaku Shibata, Shigehiro Onodera, Makoto Suzuki, Yasushi Inoue, Yoshihiro Endo, Shigeatsu PLoS One Research Article We previously reported that a soluble CD14-subtype (sCD14-ST) immunochromatographic test (ICT) for plasma is more convenient than chemiluminescent enzyme immunoassay (CLEIA), but plasma separation makes bedside measurements difficult. We developed a new sCD14-ST ICT for whole blood and investigated whether quantitative determinations of sCD14-ST by ICT were useful for diagnosing sepsis and severe sepsis/septic shock. We studied 20 patients who fulfilled two or more systemic inflammatory response syndrome (SIRS) criteria and 32 patients who had been diagnosed with sepsis or severe sepsis/septic shock. Whole blood was collected on day 0 (on admission) and day 7, and the sCD14-ST concentration was quantitatively measured by CLEIA and ICT for whole blood. The patients’ Acute Physiology and Chronic Health Evaluation (APACHE) II, Sequential Organ Failure Assessment (SOFA), and Mortality in Emergency Department Sepsis (MEDS) scores were also calculated. The cut-off values obtained by the quantitative measurements made by ICT were 464.5 pg/mL for sepsis and 762.7 pg/mL for severe sepsis/septic shock (P < 0.0001). A Bland–Altman plot showed that no fixed bias or proportional bias was detected between CLEIA and quantitative ICT for whole blood. sCD14-ST concentrations were significantly correlated with APACHE II, SOFA, and MEDS scores (P < 0.0001). These results suggest that the new sCD14-ST ICT for whole blood may be a useful tool for the convenient, rapid bedside diagnosis and treatment of sepsis. Public Library of Science 2015-12-01 /pmc/articles/PMC4666562/ /pubmed/26623644 http://dx.doi.org/10.1371/journal.pone.0143971 Text en © 2015 Sato et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Sato, Masayuki
Takahashi, Gaku
Shibata, Shigehiro
Onodera, Makoto
Suzuki, Yasushi
Inoue, Yoshihiro
Endo, Shigeatsu
Clinical Performance of a New Soluble CD14-Subtype Immunochromatographic Test for Whole Blood Compared with Chemiluminescent Enzyme Immunoassay: Use of Quantitative Soluble CD14-Subtype Immunochromatographic Tests for the Diagnosis of Sepsis
title Clinical Performance of a New Soluble CD14-Subtype Immunochromatographic Test for Whole Blood Compared with Chemiluminescent Enzyme Immunoassay: Use of Quantitative Soluble CD14-Subtype Immunochromatographic Tests for the Diagnosis of Sepsis
title_full Clinical Performance of a New Soluble CD14-Subtype Immunochromatographic Test for Whole Blood Compared with Chemiluminescent Enzyme Immunoassay: Use of Quantitative Soluble CD14-Subtype Immunochromatographic Tests for the Diagnosis of Sepsis
title_fullStr Clinical Performance of a New Soluble CD14-Subtype Immunochromatographic Test for Whole Blood Compared with Chemiluminescent Enzyme Immunoassay: Use of Quantitative Soluble CD14-Subtype Immunochromatographic Tests for the Diagnosis of Sepsis
title_full_unstemmed Clinical Performance of a New Soluble CD14-Subtype Immunochromatographic Test for Whole Blood Compared with Chemiluminescent Enzyme Immunoassay: Use of Quantitative Soluble CD14-Subtype Immunochromatographic Tests for the Diagnosis of Sepsis
title_short Clinical Performance of a New Soluble CD14-Subtype Immunochromatographic Test for Whole Blood Compared with Chemiluminescent Enzyme Immunoassay: Use of Quantitative Soluble CD14-Subtype Immunochromatographic Tests for the Diagnosis of Sepsis
title_sort clinical performance of a new soluble cd14-subtype immunochromatographic test for whole blood compared with chemiluminescent enzyme immunoassay: use of quantitative soluble cd14-subtype immunochromatographic tests for the diagnosis of sepsis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4666562/
https://www.ncbi.nlm.nih.gov/pubmed/26623644
http://dx.doi.org/10.1371/journal.pone.0143971
work_keys_str_mv AT satomasayuki clinicalperformanceofanewsolublecd14subtypeimmunochromatographictestforwholebloodcomparedwithchemiluminescentenzymeimmunoassayuseofquantitativesolublecd14subtypeimmunochromatographictestsforthediagnosisofsepsis
AT takahashigaku clinicalperformanceofanewsolublecd14subtypeimmunochromatographictestforwholebloodcomparedwithchemiluminescentenzymeimmunoassayuseofquantitativesolublecd14subtypeimmunochromatographictestsforthediagnosisofsepsis
AT shibatashigehiro clinicalperformanceofanewsolublecd14subtypeimmunochromatographictestforwholebloodcomparedwithchemiluminescentenzymeimmunoassayuseofquantitativesolublecd14subtypeimmunochromatographictestsforthediagnosisofsepsis
AT onoderamakoto clinicalperformanceofanewsolublecd14subtypeimmunochromatographictestforwholebloodcomparedwithchemiluminescentenzymeimmunoassayuseofquantitativesolublecd14subtypeimmunochromatographictestsforthediagnosisofsepsis
AT suzukiyasushi clinicalperformanceofanewsolublecd14subtypeimmunochromatographictestforwholebloodcomparedwithchemiluminescentenzymeimmunoassayuseofquantitativesolublecd14subtypeimmunochromatographictestsforthediagnosisofsepsis
AT inoueyoshihiro clinicalperformanceofanewsolublecd14subtypeimmunochromatographictestforwholebloodcomparedwithchemiluminescentenzymeimmunoassayuseofquantitativesolublecd14subtypeimmunochromatographictestsforthediagnosisofsepsis
AT endoshigeatsu clinicalperformanceofanewsolublecd14subtypeimmunochromatographictestforwholebloodcomparedwithchemiluminescentenzymeimmunoassayuseofquantitativesolublecd14subtypeimmunochromatographictestsforthediagnosisofsepsis