Cargando…

Spiral Enteroscopy Utilizing Capsule Location Index for Achieving High Diagnostic and Therapeutic Yield

Background and Aim. Spiral enteroscopy (SE) is a new small bowel endoscopic technique. Our aim is to review the diagnostic and therapeutic yield, safety of SE, and the predictive role of prior capsule endoscopy (CE) at an academic center. Methods. A retrospective review of patients undergoing SE aft...

Descripción completa

Detalles Bibliográficos
Autores principales: Mandaliya, Rohan, Korenblit, Jason, O'Hare, Brendan, Shnitser, Anastasia, Kedika, Ramalinga, Matro, Rebecca, Halegoua-De Marzio, Dina, Infantolino, Anthony, Conn, Mitchell
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4668322/
https://www.ncbi.nlm.nih.gov/pubmed/26681910
http://dx.doi.org/10.1155/2015/793516
_version_ 1782403969090322432
author Mandaliya, Rohan
Korenblit, Jason
O'Hare, Brendan
Shnitser, Anastasia
Kedika, Ramalinga
Matro, Rebecca
Halegoua-De Marzio, Dina
Infantolino, Anthony
Conn, Mitchell
author_facet Mandaliya, Rohan
Korenblit, Jason
O'Hare, Brendan
Shnitser, Anastasia
Kedika, Ramalinga
Matro, Rebecca
Halegoua-De Marzio, Dina
Infantolino, Anthony
Conn, Mitchell
author_sort Mandaliya, Rohan
collection PubMed
description Background and Aim. Spiral enteroscopy (SE) is a new small bowel endoscopic technique. Our aim is to review the diagnostic and therapeutic yield, safety of SE, and the predictive role of prior capsule endoscopy (CE) at an academic center. Methods. A retrospective review of patients undergoing SE after prior CE between 2008 and 2013 was performed. Capsule location index (CLI) was defined as the fraction of total small bowel transit time when the lesion was seen on CE. Results. A total of 174 SEs were performed: antegrade (147) and retrograde (27). Abnormalities on SE were detected in 65% patients. The procedure was safe in patients with surgically altered bowel anatomy (n = 12). The diagnostic yield of antegrade SE decreased with increasing CLI range. The diagnostic yield of retrograde SE decreased on decreasing CLI range. A CLI cutoff of 0.6 was derived that determined the initial route of SE. Vascular ectasias seen on CE were detected in 83% cases on SE; p < 0.01. Conclusions. SE is safe with a high diagnostic and therapeutic yield. CLI is predictive of the success of SE and determines the best route of SE. The type of small bowel pathology targeted by SE may affect its utility and yield.
format Online
Article
Text
id pubmed-4668322
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-46683222015-12-17 Spiral Enteroscopy Utilizing Capsule Location Index for Achieving High Diagnostic and Therapeutic Yield Mandaliya, Rohan Korenblit, Jason O'Hare, Brendan Shnitser, Anastasia Kedika, Ramalinga Matro, Rebecca Halegoua-De Marzio, Dina Infantolino, Anthony Conn, Mitchell Diagn Ther Endosc Research Article Background and Aim. Spiral enteroscopy (SE) is a new small bowel endoscopic technique. Our aim is to review the diagnostic and therapeutic yield, safety of SE, and the predictive role of prior capsule endoscopy (CE) at an academic center. Methods. A retrospective review of patients undergoing SE after prior CE between 2008 and 2013 was performed. Capsule location index (CLI) was defined as the fraction of total small bowel transit time when the lesion was seen on CE. Results. A total of 174 SEs were performed: antegrade (147) and retrograde (27). Abnormalities on SE were detected in 65% patients. The procedure was safe in patients with surgically altered bowel anatomy (n = 12). The diagnostic yield of antegrade SE decreased with increasing CLI range. The diagnostic yield of retrograde SE decreased on decreasing CLI range. A CLI cutoff of 0.6 was derived that determined the initial route of SE. Vascular ectasias seen on CE were detected in 83% cases on SE; p < 0.01. Conclusions. SE is safe with a high diagnostic and therapeutic yield. CLI is predictive of the success of SE and determines the best route of SE. The type of small bowel pathology targeted by SE may affect its utility and yield. Hindawi Publishing Corporation 2015 2015-11-19 /pmc/articles/PMC4668322/ /pubmed/26681910 http://dx.doi.org/10.1155/2015/793516 Text en Copyright © 2015 Rohan Mandaliya et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Mandaliya, Rohan
Korenblit, Jason
O'Hare, Brendan
Shnitser, Anastasia
Kedika, Ramalinga
Matro, Rebecca
Halegoua-De Marzio, Dina
Infantolino, Anthony
Conn, Mitchell
Spiral Enteroscopy Utilizing Capsule Location Index for Achieving High Diagnostic and Therapeutic Yield
title Spiral Enteroscopy Utilizing Capsule Location Index for Achieving High Diagnostic and Therapeutic Yield
title_full Spiral Enteroscopy Utilizing Capsule Location Index for Achieving High Diagnostic and Therapeutic Yield
title_fullStr Spiral Enteroscopy Utilizing Capsule Location Index for Achieving High Diagnostic and Therapeutic Yield
title_full_unstemmed Spiral Enteroscopy Utilizing Capsule Location Index for Achieving High Diagnostic and Therapeutic Yield
title_short Spiral Enteroscopy Utilizing Capsule Location Index for Achieving High Diagnostic and Therapeutic Yield
title_sort spiral enteroscopy utilizing capsule location index for achieving high diagnostic and therapeutic yield
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4668322/
https://www.ncbi.nlm.nih.gov/pubmed/26681910
http://dx.doi.org/10.1155/2015/793516
work_keys_str_mv AT mandaliyarohan spiralenteroscopyutilizingcapsulelocationindexforachievinghighdiagnosticandtherapeuticyield
AT korenblitjason spiralenteroscopyutilizingcapsulelocationindexforachievinghighdiagnosticandtherapeuticyield
AT oharebrendan spiralenteroscopyutilizingcapsulelocationindexforachievinghighdiagnosticandtherapeuticyield
AT shnitseranastasia spiralenteroscopyutilizingcapsulelocationindexforachievinghighdiagnosticandtherapeuticyield
AT kedikaramalinga spiralenteroscopyutilizingcapsulelocationindexforachievinghighdiagnosticandtherapeuticyield
AT matrorebecca spiralenteroscopyutilizingcapsulelocationindexforachievinghighdiagnosticandtherapeuticyield
AT halegouademarziodina spiralenteroscopyutilizingcapsulelocationindexforachievinghighdiagnosticandtherapeuticyield
AT infantolinoanthony spiralenteroscopyutilizingcapsulelocationindexforachievinghighdiagnosticandtherapeuticyield
AT connmitchell spiralenteroscopyutilizingcapsulelocationindexforachievinghighdiagnosticandtherapeuticyield