Non-contrast-enhanced hepatic MR arteriography with balanced steady-state free-precession and time spatial labeling inversion pulse: optimization of the inversion time at 3 Tesla

BACKGROUND: A 3 Tesla (3 T) magnetic resonance (MR) scanner is a promising tool for upper abdominal angiography. However, no report has focused on the contrast behavior of non-contrast-enhanced hepatic MR arteriography at 3 T. PURPOSE: To establish the optimal inversion time (TI) for favorable selec...

Descripción completa

Detalles Bibliográficos
Autores principales: Kawahara, Seiya, Isoda, Hiroyoshi, Ohno, Tsuyoshi, Furuta, Akihiro, Togashi, Kaori
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4668994/
https://www.ncbi.nlm.nih.gov/pubmed/26668756
http://dx.doi.org/10.1177/2058460115616427
_version_ 1782404046964916224
author Kawahara, Seiya
Isoda, Hiroyoshi
Ohno, Tsuyoshi
Furuta, Akihiro
Togashi, Kaori
author_facet Kawahara, Seiya
Isoda, Hiroyoshi
Ohno, Tsuyoshi
Furuta, Akihiro
Togashi, Kaori
author_sort Kawahara, Seiya
collection PubMed
description BACKGROUND: A 3 Tesla (3 T) magnetic resonance (MR) scanner is a promising tool for upper abdominal angiography. However, no report has focused on the contrast behavior of non-contrast-enhanced hepatic MR arteriography at 3 T. PURPOSE: To establish the optimal inversion time (TI) for favorable selective visualization of the hepatic arteries on non-contrast-enhanced MR arteriography with time spatial labeling inversion pulse (Time-SLIP) at 3 T. MATERIAL AND METHODS: Twenty-five healthy volunteers were examined using respiratory-triggered three-dimensional balanced steady-state free-precession combined with Time-SLIP. According to the difference in the TI, five image groups (A, B, C, D, and E, from 1200 to 2000 ms, increasing at 200-ms intervals) were performed and compared to detect the optimal TI for hepatic artery visualization. The relative Cv-l (vessel-to-liver contrast) was quantified. For qualitative evaluation, the vessel visualization quality and order of the depicted hepatic artery branches were evaluated. RESULTS: In group C (TI of 1600 ms), the Cv-l showed the highest probably due to a favorable balance between the hepatic vessel signal and signal recovery of the surrounding tissue. Regarding qualitative assessment, in group C, the mean image quality score of all hepatic arteries and mean maximal visible order of the hepatic artery branches were the highest. However, there was no significant difference between these results. CONCLUSION: Non-contrast-enhanced hepatic MR arteriography with Time-SLIP at 3 T enabled the selective visualization of hepatic arteries at a TI of 1600 ms with an optimal balance between Cv-l and peripheral hepatic artery visualization.
format Online
Article
Text
id pubmed-4668994
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-46689942015-12-14 Non-contrast-enhanced hepatic MR arteriography with balanced steady-state free-precession and time spatial labeling inversion pulse: optimization of the inversion time at 3 Tesla Kawahara, Seiya Isoda, Hiroyoshi Ohno, Tsuyoshi Furuta, Akihiro Togashi, Kaori Acta Radiol Open Research BACKGROUND: A 3 Tesla (3 T) magnetic resonance (MR) scanner is a promising tool for upper abdominal angiography. However, no report has focused on the contrast behavior of non-contrast-enhanced hepatic MR arteriography at 3 T. PURPOSE: To establish the optimal inversion time (TI) for favorable selective visualization of the hepatic arteries on non-contrast-enhanced MR arteriography with time spatial labeling inversion pulse (Time-SLIP) at 3 T. MATERIAL AND METHODS: Twenty-five healthy volunteers were examined using respiratory-triggered three-dimensional balanced steady-state free-precession combined with Time-SLIP. According to the difference in the TI, five image groups (A, B, C, D, and E, from 1200 to 2000 ms, increasing at 200-ms intervals) were performed and compared to detect the optimal TI for hepatic artery visualization. The relative Cv-l (vessel-to-liver contrast) was quantified. For qualitative evaluation, the vessel visualization quality and order of the depicted hepatic artery branches were evaluated. RESULTS: In group C (TI of 1600 ms), the Cv-l showed the highest probably due to a favorable balance between the hepatic vessel signal and signal recovery of the surrounding tissue. Regarding qualitative assessment, in group C, the mean image quality score of all hepatic arteries and mean maximal visible order of the hepatic artery branches were the highest. However, there was no significant difference between these results. CONCLUSION: Non-contrast-enhanced hepatic MR arteriography with Time-SLIP at 3 T enabled the selective visualization of hepatic arteries at a TI of 1600 ms with an optimal balance between Cv-l and peripheral hepatic artery visualization. SAGE Publications 2015-11-27 /pmc/articles/PMC4668994/ /pubmed/26668756 http://dx.doi.org/10.1177/2058460115616427 Text en © The Foundation Acta Radiologica 2015 http://creativecommons.org/licenses/by-nc/3.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 3.0 License (http://www.creativecommons.org/licenses/by-nc/3.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page(https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Research
Kawahara, Seiya
Isoda, Hiroyoshi
Ohno, Tsuyoshi
Furuta, Akihiro
Togashi, Kaori
Non-contrast-enhanced hepatic MR arteriography with balanced steady-state free-precession and time spatial labeling inversion pulse: optimization of the inversion time at 3 Tesla
title Non-contrast-enhanced hepatic MR arteriography with balanced steady-state free-precession and time spatial labeling inversion pulse: optimization of the inversion time at 3 Tesla
title_full Non-contrast-enhanced hepatic MR arteriography with balanced steady-state free-precession and time spatial labeling inversion pulse: optimization of the inversion time at 3 Tesla
title_fullStr Non-contrast-enhanced hepatic MR arteriography with balanced steady-state free-precession and time spatial labeling inversion pulse: optimization of the inversion time at 3 Tesla
title_full_unstemmed Non-contrast-enhanced hepatic MR arteriography with balanced steady-state free-precession and time spatial labeling inversion pulse: optimization of the inversion time at 3 Tesla
title_short Non-contrast-enhanced hepatic MR arteriography with balanced steady-state free-precession and time spatial labeling inversion pulse: optimization of the inversion time at 3 Tesla
title_sort non-contrast-enhanced hepatic mr arteriography with balanced steady-state free-precession and time spatial labeling inversion pulse: optimization of the inversion time at 3 tesla
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4668994/
https://www.ncbi.nlm.nih.gov/pubmed/26668756
http://dx.doi.org/10.1177/2058460115616427
work_keys_str_mv AT kawaharaseiya noncontrastenhancedhepaticmrarteriographywithbalancedsteadystatefreeprecessionandtimespatiallabelinginversionpulseoptimizationoftheinversiontimeat3tesla
AT isodahiroyoshi noncontrastenhancedhepaticmrarteriographywithbalancedsteadystatefreeprecessionandtimespatiallabelinginversionpulseoptimizationoftheinversiontimeat3tesla
AT ohnotsuyoshi noncontrastenhancedhepaticmrarteriographywithbalancedsteadystatefreeprecessionandtimespatiallabelinginversionpulseoptimizationoftheinversiontimeat3tesla
AT furutaakihiro noncontrastenhancedhepaticmrarteriographywithbalancedsteadystatefreeprecessionandtimespatiallabelinginversionpulseoptimizationoftheinversiontimeat3tesla
AT togashikaori noncontrastenhancedhepaticmrarteriographywithbalancedsteadystatefreeprecessionandtimespatiallabelinginversionpulseoptimizationoftheinversiontimeat3tesla