Quantitative three-dimensional myocardial perfusion cardiovascular magnetic resonance with accurate two-dimensional arterial input function assessment

BACKGROUND: Quantification of myocardial perfusion from first-pass cardiovascular magnetic resonance (CMR) images at high contrast agent (CA) dose requires separate acquisition of blood pool and myocardial tissue enhancement. In this study, a dual-sequence approach interleaving 2D imaging of the art...

Descripción completa

Detalles Bibliográficos
Autores principales: Wissmann, Lukas, Niemann, Markus, Gotschy, Alexander, Manka, Robert, Kozerke, Sebastian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4669617/
https://www.ncbi.nlm.nih.gov/pubmed/26637221
http://dx.doi.org/10.1186/s12968-015-0212-3
_version_ 1782404129533984768
author Wissmann, Lukas
Niemann, Markus
Gotschy, Alexander
Manka, Robert
Kozerke, Sebastian
author_facet Wissmann, Lukas
Niemann, Markus
Gotschy, Alexander
Manka, Robert
Kozerke, Sebastian
author_sort Wissmann, Lukas
collection PubMed
description BACKGROUND: Quantification of myocardial perfusion from first-pass cardiovascular magnetic resonance (CMR) images at high contrast agent (CA) dose requires separate acquisition of blood pool and myocardial tissue enhancement. In this study, a dual-sequence approach interleaving 2D imaging of the arterial input function with high-resolution 3D imaging for myocardial perfusion assessment is presented and validated for low and high CA dose. METHODS: A dual-sequence approach interleaving 2D imaging of the aortic root and 3D imaging of the whole left ventricle using highly accelerated k-t PCA was implemented. Rest perfusion imaging was performed in ten healthy volunteers after administration of a Gadolinium-based CA at low (0.025 mmol/kg b.w.) and high dose (0.1 mmol/kg b.w.). Arterial input functions extracted from the 2D and 3D images were analysed for both doses. Myocardial contrast-to-noise ratios (CNR) were compared across volunteers and doses. Variations of myocardial perfusion estimates between volunteers and across myocardial territories were studied. RESULTS: High CA dose imaging resulted in strong non-linearity of the arterial input function in the 3D images at peak CA concentration, which was avoided when the input function was derived from the 2D images. Myocardial CNR was significantly increased at high dose compared to low dose, with a 2.6-fold mean CNR gain. Most robust myocardial blood flow estimation was achieved using the arterial input function extracted from the 2D image at high CA dose. In this case, myocardial blood flow estimates varied by 24 % between volunteers and by 20 % between myocardial territories when analysed on a per-volunteer basis. CONCLUSION: Interleaving 2D imaging for arterial input function assessment enables robust quantitative 3D myocardial perfusion imaging at high CA dose.
format Online
Article
Text
id pubmed-4669617
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-46696172015-12-10 Quantitative three-dimensional myocardial perfusion cardiovascular magnetic resonance with accurate two-dimensional arterial input function assessment Wissmann, Lukas Niemann, Markus Gotschy, Alexander Manka, Robert Kozerke, Sebastian J Cardiovasc Magn Reson Research BACKGROUND: Quantification of myocardial perfusion from first-pass cardiovascular magnetic resonance (CMR) images at high contrast agent (CA) dose requires separate acquisition of blood pool and myocardial tissue enhancement. In this study, a dual-sequence approach interleaving 2D imaging of the arterial input function with high-resolution 3D imaging for myocardial perfusion assessment is presented and validated for low and high CA dose. METHODS: A dual-sequence approach interleaving 2D imaging of the aortic root and 3D imaging of the whole left ventricle using highly accelerated k-t PCA was implemented. Rest perfusion imaging was performed in ten healthy volunteers after administration of a Gadolinium-based CA at low (0.025 mmol/kg b.w.) and high dose (0.1 mmol/kg b.w.). Arterial input functions extracted from the 2D and 3D images were analysed for both doses. Myocardial contrast-to-noise ratios (CNR) were compared across volunteers and doses. Variations of myocardial perfusion estimates between volunteers and across myocardial territories were studied. RESULTS: High CA dose imaging resulted in strong non-linearity of the arterial input function in the 3D images at peak CA concentration, which was avoided when the input function was derived from the 2D images. Myocardial CNR was significantly increased at high dose compared to low dose, with a 2.6-fold mean CNR gain. Most robust myocardial blood flow estimation was achieved using the arterial input function extracted from the 2D image at high CA dose. In this case, myocardial blood flow estimates varied by 24 % between volunteers and by 20 % between myocardial territories when analysed on a per-volunteer basis. CONCLUSION: Interleaving 2D imaging for arterial input function assessment enables robust quantitative 3D myocardial perfusion imaging at high CA dose. BioMed Central 2015-12-04 /pmc/articles/PMC4669617/ /pubmed/26637221 http://dx.doi.org/10.1186/s12968-015-0212-3 Text en © Wissmann et al. 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Wissmann, Lukas
Niemann, Markus
Gotschy, Alexander
Manka, Robert
Kozerke, Sebastian
Quantitative three-dimensional myocardial perfusion cardiovascular magnetic resonance with accurate two-dimensional arterial input function assessment
title Quantitative three-dimensional myocardial perfusion cardiovascular magnetic resonance with accurate two-dimensional arterial input function assessment
title_full Quantitative three-dimensional myocardial perfusion cardiovascular magnetic resonance with accurate two-dimensional arterial input function assessment
title_fullStr Quantitative three-dimensional myocardial perfusion cardiovascular magnetic resonance with accurate two-dimensional arterial input function assessment
title_full_unstemmed Quantitative three-dimensional myocardial perfusion cardiovascular magnetic resonance with accurate two-dimensional arterial input function assessment
title_short Quantitative three-dimensional myocardial perfusion cardiovascular magnetic resonance with accurate two-dimensional arterial input function assessment
title_sort quantitative three-dimensional myocardial perfusion cardiovascular magnetic resonance with accurate two-dimensional arterial input function assessment
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4669617/
https://www.ncbi.nlm.nih.gov/pubmed/26637221
http://dx.doi.org/10.1186/s12968-015-0212-3
work_keys_str_mv AT wissmannlukas quantitativethreedimensionalmyocardialperfusioncardiovascularmagneticresonancewithaccuratetwodimensionalarterialinputfunctionassessment
AT niemannmarkus quantitativethreedimensionalmyocardialperfusioncardiovascularmagneticresonancewithaccuratetwodimensionalarterialinputfunctionassessment
AT gotschyalexander quantitativethreedimensionalmyocardialperfusioncardiovascularmagneticresonancewithaccuratetwodimensionalarterialinputfunctionassessment
AT mankarobert quantitativethreedimensionalmyocardialperfusioncardiovascularmagneticresonancewithaccuratetwodimensionalarterialinputfunctionassessment
AT kozerkesebastian quantitativethreedimensionalmyocardialperfusioncardiovascularmagneticresonancewithaccuratetwodimensionalarterialinputfunctionassessment