Cargando…

Transient Intervals of Hyper-Gravity Enhance Endothelial Barrier Integrity: Impact of Mechanical and Gravitational Forces Measured Electrically

BACKGROUND: Endothelial cells (EC) guard vascular functions by forming a dynamic barrier throughout the vascular system that sensitively adapts to ‘classical’ biomechanical forces, such as fluid shear stress and hydrostatic pressure. Alterations in gravitational forces might similarly affect EC inte...

Descripción completa

Detalles Bibliográficos
Autores principales: Szulcek, Robert, van Bezu, Jan, Boonstra, Johannes, van Loon, Jack J. W. A., van Nieuw Amerongen, Geerten P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4670102/
https://www.ncbi.nlm.nih.gov/pubmed/26637177
http://dx.doi.org/10.1371/journal.pone.0144269
_version_ 1782404214449766400
author Szulcek, Robert
van Bezu, Jan
Boonstra, Johannes
van Loon, Jack J. W. A.
van Nieuw Amerongen, Geerten P.
author_facet Szulcek, Robert
van Bezu, Jan
Boonstra, Johannes
van Loon, Jack J. W. A.
van Nieuw Amerongen, Geerten P.
author_sort Szulcek, Robert
collection PubMed
description BACKGROUND: Endothelial cells (EC) guard vascular functions by forming a dynamic barrier throughout the vascular system that sensitively adapts to ‘classical’ biomechanical forces, such as fluid shear stress and hydrostatic pressure. Alterations in gravitational forces might similarly affect EC integrity, but remain insufficiently studied. METHODS: In an unique approach, we utilized Electric Cell-substrate Impedance Sensing (ECIS) in the gravity-simulators at the European Space Agency (ESA) to study dynamic responses of human EC to simulated micro- and hyper-gravity as well as to classical forces. RESULTS: Short intervals of micro- or hyper-gravity evoked distinct endothelial responses. Stimulated micro-gravity led to decreased endothelial barrier integrity, whereas hyper-gravity caused sustained barrier enhancement by rapid improvement of cell-cell integrity, evidenced by a significant junctional accumulation of VE-cadherin (p = 0.011), significant enforcement of peripheral F-actin (p = 0.008) and accompanied by a slower enhancement of cell-matrix interactions. The hyper-gravity triggered EC responses were force dependent and nitric-oxide (NO) mediated showing a maximal resistance increase of 29.2±4.8 ohms at 2g and 60.9±6.2 ohms at 4g vs. baseline values that was significantly suppressed by NO blockage (p = 0.011). CONCLUSION: In conclusion, short-term application of hyper-gravity caused a sustained improvement of endothelial barrier integrity, whereas simulated micro-gravity weakened the endothelium. In clear contrast, classical forces of shear stress and hydrostatic pressure induced either short-lived or no changes to the EC barrier. Here, ECIS has proven a powerful tool to characterize subtle and distinct EC gravity-responses due to its high temporal resolution, wherefore ECIS has a great potential for the study of gravity-responses such as in real space flights providing quantitative assessment of a variety of cell biological characteristics of any adherent growing cell type in an automated and continuous fashion.
format Online
Article
Text
id pubmed-4670102
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-46701022015-12-10 Transient Intervals of Hyper-Gravity Enhance Endothelial Barrier Integrity: Impact of Mechanical and Gravitational Forces Measured Electrically Szulcek, Robert van Bezu, Jan Boonstra, Johannes van Loon, Jack J. W. A. van Nieuw Amerongen, Geerten P. PLoS One Research Article BACKGROUND: Endothelial cells (EC) guard vascular functions by forming a dynamic barrier throughout the vascular system that sensitively adapts to ‘classical’ biomechanical forces, such as fluid shear stress and hydrostatic pressure. Alterations in gravitational forces might similarly affect EC integrity, but remain insufficiently studied. METHODS: In an unique approach, we utilized Electric Cell-substrate Impedance Sensing (ECIS) in the gravity-simulators at the European Space Agency (ESA) to study dynamic responses of human EC to simulated micro- and hyper-gravity as well as to classical forces. RESULTS: Short intervals of micro- or hyper-gravity evoked distinct endothelial responses. Stimulated micro-gravity led to decreased endothelial barrier integrity, whereas hyper-gravity caused sustained barrier enhancement by rapid improvement of cell-cell integrity, evidenced by a significant junctional accumulation of VE-cadherin (p = 0.011), significant enforcement of peripheral F-actin (p = 0.008) and accompanied by a slower enhancement of cell-matrix interactions. The hyper-gravity triggered EC responses were force dependent and nitric-oxide (NO) mediated showing a maximal resistance increase of 29.2±4.8 ohms at 2g and 60.9±6.2 ohms at 4g vs. baseline values that was significantly suppressed by NO blockage (p = 0.011). CONCLUSION: In conclusion, short-term application of hyper-gravity caused a sustained improvement of endothelial barrier integrity, whereas simulated micro-gravity weakened the endothelium. In clear contrast, classical forces of shear stress and hydrostatic pressure induced either short-lived or no changes to the EC barrier. Here, ECIS has proven a powerful tool to characterize subtle and distinct EC gravity-responses due to its high temporal resolution, wherefore ECIS has a great potential for the study of gravity-responses such as in real space flights providing quantitative assessment of a variety of cell biological characteristics of any adherent growing cell type in an automated and continuous fashion. Public Library of Science 2015-12-04 /pmc/articles/PMC4670102/ /pubmed/26637177 http://dx.doi.org/10.1371/journal.pone.0144269 Text en © 2015 Szulcek et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Szulcek, Robert
van Bezu, Jan
Boonstra, Johannes
van Loon, Jack J. W. A.
van Nieuw Amerongen, Geerten P.
Transient Intervals of Hyper-Gravity Enhance Endothelial Barrier Integrity: Impact of Mechanical and Gravitational Forces Measured Electrically
title Transient Intervals of Hyper-Gravity Enhance Endothelial Barrier Integrity: Impact of Mechanical and Gravitational Forces Measured Electrically
title_full Transient Intervals of Hyper-Gravity Enhance Endothelial Barrier Integrity: Impact of Mechanical and Gravitational Forces Measured Electrically
title_fullStr Transient Intervals of Hyper-Gravity Enhance Endothelial Barrier Integrity: Impact of Mechanical and Gravitational Forces Measured Electrically
title_full_unstemmed Transient Intervals of Hyper-Gravity Enhance Endothelial Barrier Integrity: Impact of Mechanical and Gravitational Forces Measured Electrically
title_short Transient Intervals of Hyper-Gravity Enhance Endothelial Barrier Integrity: Impact of Mechanical and Gravitational Forces Measured Electrically
title_sort transient intervals of hyper-gravity enhance endothelial barrier integrity: impact of mechanical and gravitational forces measured electrically
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4670102/
https://www.ncbi.nlm.nih.gov/pubmed/26637177
http://dx.doi.org/10.1371/journal.pone.0144269
work_keys_str_mv AT szulcekrobert transientintervalsofhypergravityenhanceendothelialbarrierintegrityimpactofmechanicalandgravitationalforcesmeasuredelectrically
AT vanbezujan transientintervalsofhypergravityenhanceendothelialbarrierintegrityimpactofmechanicalandgravitationalforcesmeasuredelectrically
AT boonstrajohannes transientintervalsofhypergravityenhanceendothelialbarrierintegrityimpactofmechanicalandgravitationalforcesmeasuredelectrically
AT vanloonjackjwa transientintervalsofhypergravityenhanceendothelialbarrierintegrityimpactofmechanicalandgravitationalforcesmeasuredelectrically
AT vannieuwamerongengeertenp transientintervalsofhypergravityenhanceendothelialbarrierintegrityimpactofmechanicalandgravitationalforcesmeasuredelectrically