Cargando…
Transient Intervals of Hyper-Gravity Enhance Endothelial Barrier Integrity: Impact of Mechanical and Gravitational Forces Measured Electrically
BACKGROUND: Endothelial cells (EC) guard vascular functions by forming a dynamic barrier throughout the vascular system that sensitively adapts to ‘classical’ biomechanical forces, such as fluid shear stress and hydrostatic pressure. Alterations in gravitational forces might similarly affect EC inte...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4670102/ https://www.ncbi.nlm.nih.gov/pubmed/26637177 http://dx.doi.org/10.1371/journal.pone.0144269 |
_version_ | 1782404214449766400 |
---|---|
author | Szulcek, Robert van Bezu, Jan Boonstra, Johannes van Loon, Jack J. W. A. van Nieuw Amerongen, Geerten P. |
author_facet | Szulcek, Robert van Bezu, Jan Boonstra, Johannes van Loon, Jack J. W. A. van Nieuw Amerongen, Geerten P. |
author_sort | Szulcek, Robert |
collection | PubMed |
description | BACKGROUND: Endothelial cells (EC) guard vascular functions by forming a dynamic barrier throughout the vascular system that sensitively adapts to ‘classical’ biomechanical forces, such as fluid shear stress and hydrostatic pressure. Alterations in gravitational forces might similarly affect EC integrity, but remain insufficiently studied. METHODS: In an unique approach, we utilized Electric Cell-substrate Impedance Sensing (ECIS) in the gravity-simulators at the European Space Agency (ESA) to study dynamic responses of human EC to simulated micro- and hyper-gravity as well as to classical forces. RESULTS: Short intervals of micro- or hyper-gravity evoked distinct endothelial responses. Stimulated micro-gravity led to decreased endothelial barrier integrity, whereas hyper-gravity caused sustained barrier enhancement by rapid improvement of cell-cell integrity, evidenced by a significant junctional accumulation of VE-cadherin (p = 0.011), significant enforcement of peripheral F-actin (p = 0.008) and accompanied by a slower enhancement of cell-matrix interactions. The hyper-gravity triggered EC responses were force dependent and nitric-oxide (NO) mediated showing a maximal resistance increase of 29.2±4.8 ohms at 2g and 60.9±6.2 ohms at 4g vs. baseline values that was significantly suppressed by NO blockage (p = 0.011). CONCLUSION: In conclusion, short-term application of hyper-gravity caused a sustained improvement of endothelial barrier integrity, whereas simulated micro-gravity weakened the endothelium. In clear contrast, classical forces of shear stress and hydrostatic pressure induced either short-lived or no changes to the EC barrier. Here, ECIS has proven a powerful tool to characterize subtle and distinct EC gravity-responses due to its high temporal resolution, wherefore ECIS has a great potential for the study of gravity-responses such as in real space flights providing quantitative assessment of a variety of cell biological characteristics of any adherent growing cell type in an automated and continuous fashion. |
format | Online Article Text |
id | pubmed-4670102 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-46701022015-12-10 Transient Intervals of Hyper-Gravity Enhance Endothelial Barrier Integrity: Impact of Mechanical and Gravitational Forces Measured Electrically Szulcek, Robert van Bezu, Jan Boonstra, Johannes van Loon, Jack J. W. A. van Nieuw Amerongen, Geerten P. PLoS One Research Article BACKGROUND: Endothelial cells (EC) guard vascular functions by forming a dynamic barrier throughout the vascular system that sensitively adapts to ‘classical’ biomechanical forces, such as fluid shear stress and hydrostatic pressure. Alterations in gravitational forces might similarly affect EC integrity, but remain insufficiently studied. METHODS: In an unique approach, we utilized Electric Cell-substrate Impedance Sensing (ECIS) in the gravity-simulators at the European Space Agency (ESA) to study dynamic responses of human EC to simulated micro- and hyper-gravity as well as to classical forces. RESULTS: Short intervals of micro- or hyper-gravity evoked distinct endothelial responses. Stimulated micro-gravity led to decreased endothelial barrier integrity, whereas hyper-gravity caused sustained barrier enhancement by rapid improvement of cell-cell integrity, evidenced by a significant junctional accumulation of VE-cadherin (p = 0.011), significant enforcement of peripheral F-actin (p = 0.008) and accompanied by a slower enhancement of cell-matrix interactions. The hyper-gravity triggered EC responses were force dependent and nitric-oxide (NO) mediated showing a maximal resistance increase of 29.2±4.8 ohms at 2g and 60.9±6.2 ohms at 4g vs. baseline values that was significantly suppressed by NO blockage (p = 0.011). CONCLUSION: In conclusion, short-term application of hyper-gravity caused a sustained improvement of endothelial barrier integrity, whereas simulated micro-gravity weakened the endothelium. In clear contrast, classical forces of shear stress and hydrostatic pressure induced either short-lived or no changes to the EC barrier. Here, ECIS has proven a powerful tool to characterize subtle and distinct EC gravity-responses due to its high temporal resolution, wherefore ECIS has a great potential for the study of gravity-responses such as in real space flights providing quantitative assessment of a variety of cell biological characteristics of any adherent growing cell type in an automated and continuous fashion. Public Library of Science 2015-12-04 /pmc/articles/PMC4670102/ /pubmed/26637177 http://dx.doi.org/10.1371/journal.pone.0144269 Text en © 2015 Szulcek et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Szulcek, Robert van Bezu, Jan Boonstra, Johannes van Loon, Jack J. W. A. van Nieuw Amerongen, Geerten P. Transient Intervals of Hyper-Gravity Enhance Endothelial Barrier Integrity: Impact of Mechanical and Gravitational Forces Measured Electrically |
title | Transient Intervals of Hyper-Gravity Enhance Endothelial Barrier Integrity: Impact of Mechanical and Gravitational Forces Measured Electrically |
title_full | Transient Intervals of Hyper-Gravity Enhance Endothelial Barrier Integrity: Impact of Mechanical and Gravitational Forces Measured Electrically |
title_fullStr | Transient Intervals of Hyper-Gravity Enhance Endothelial Barrier Integrity: Impact of Mechanical and Gravitational Forces Measured Electrically |
title_full_unstemmed | Transient Intervals of Hyper-Gravity Enhance Endothelial Barrier Integrity: Impact of Mechanical and Gravitational Forces Measured Electrically |
title_short | Transient Intervals of Hyper-Gravity Enhance Endothelial Barrier Integrity: Impact of Mechanical and Gravitational Forces Measured Electrically |
title_sort | transient intervals of hyper-gravity enhance endothelial barrier integrity: impact of mechanical and gravitational forces measured electrically |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4670102/ https://www.ncbi.nlm.nih.gov/pubmed/26637177 http://dx.doi.org/10.1371/journal.pone.0144269 |
work_keys_str_mv | AT szulcekrobert transientintervalsofhypergravityenhanceendothelialbarrierintegrityimpactofmechanicalandgravitationalforcesmeasuredelectrically AT vanbezujan transientintervalsofhypergravityenhanceendothelialbarrierintegrityimpactofmechanicalandgravitationalforcesmeasuredelectrically AT boonstrajohannes transientintervalsofhypergravityenhanceendothelialbarrierintegrityimpactofmechanicalandgravitationalforcesmeasuredelectrically AT vanloonjackjwa transientintervalsofhypergravityenhanceendothelialbarrierintegrityimpactofmechanicalandgravitationalforcesmeasuredelectrically AT vannieuwamerongengeertenp transientintervalsofhypergravityenhanceendothelialbarrierintegrityimpactofmechanicalandgravitationalforcesmeasuredelectrically |