Aortic perforation due to cardiac resynchronisation therapy defibrillator lead placement: Case report and medicolegal considerations

A 45-year-old woman with dilated cardiomyopathy was admitted for the upgrade of a previously implanted pacemaker. Echocardiography showed intraventricular dyssynchrony and a low ejection fraction (0.35). Treatment with a cardiac resynchronization therapy defibrillator (CRT-D) was selected and the de...

Descripción completa

Detalles Bibliográficos
Autores principales: Grande, Antonino M., Fiore, Antonio, Merlano, Maurizio, Buzzi, Fabio, Mazzola, Alessandro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4672031/
https://www.ncbi.nlm.nih.gov/pubmed/26702323
http://dx.doi.org/10.1016/j.joa.2015.05.002
_version_ 1782404488555921408
author Grande, Antonino M.
Fiore, Antonio
Merlano, Maurizio
Buzzi, Fabio
Mazzola, Alessandro
author_facet Grande, Antonino M.
Fiore, Antonio
Merlano, Maurizio
Buzzi, Fabio
Mazzola, Alessandro
author_sort Grande, Antonino M.
collection PubMed
description A 45-year-old woman with dilated cardiomyopathy was admitted for the upgrade of a previously implanted pacemaker. Echocardiography showed intraventricular dyssynchrony and a low ejection fraction (0.35). Treatment with a cardiac resynchronization therapy defibrillator (CRT-D) was selected and the device was implanted. CRT-D interrogation revealed proper function. Following procedure termination, the patient went into cardiac arrest and died despite resuscitation attempts. An autopsy revealed that the medial aspect of the right atrium was pierced by an active lead and that the aorta had a deep lesion, 2 mm in length, on its lateral aspect. We explain the probable pathogenesis of this patient׳s death.
format Online
Article
Text
id pubmed-4672031
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-46720312015-12-23 Aortic perforation due to cardiac resynchronisation therapy defibrillator lead placement: Case report and medicolegal considerations Grande, Antonino M. Fiore, Antonio Merlano, Maurizio Buzzi, Fabio Mazzola, Alessandro J Arrhythm Case Report A 45-year-old woman with dilated cardiomyopathy was admitted for the upgrade of a previously implanted pacemaker. Echocardiography showed intraventricular dyssynchrony and a low ejection fraction (0.35). Treatment with a cardiac resynchronization therapy defibrillator (CRT-D) was selected and the device was implanted. CRT-D interrogation revealed proper function. Following procedure termination, the patient went into cardiac arrest and died despite resuscitation attempts. An autopsy revealed that the medial aspect of the right atrium was pierced by an active lead and that the aorta had a deep lesion, 2 mm in length, on its lateral aspect. We explain the probable pathogenesis of this patient׳s death. Elsevier 2015-12 2015-06-16 /pmc/articles/PMC4672031/ /pubmed/26702323 http://dx.doi.org/10.1016/j.joa.2015.05.002 Text en © 2015 Japanese Heart Rhythm Society. Published by Elsevier B.V. All rights reserved. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Grande, Antonino M.
Fiore, Antonio
Merlano, Maurizio
Buzzi, Fabio
Mazzola, Alessandro
Aortic perforation due to cardiac resynchronisation therapy defibrillator lead placement: Case report and medicolegal considerations
title Aortic perforation due to cardiac resynchronisation therapy defibrillator lead placement: Case report and medicolegal considerations
title_full Aortic perforation due to cardiac resynchronisation therapy defibrillator lead placement: Case report and medicolegal considerations
title_fullStr Aortic perforation due to cardiac resynchronisation therapy defibrillator lead placement: Case report and medicolegal considerations
title_full_unstemmed Aortic perforation due to cardiac resynchronisation therapy defibrillator lead placement: Case report and medicolegal considerations
title_short Aortic perforation due to cardiac resynchronisation therapy defibrillator lead placement: Case report and medicolegal considerations
title_sort aortic perforation due to cardiac resynchronisation therapy defibrillator lead placement: case report and medicolegal considerations
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4672031/
https://www.ncbi.nlm.nih.gov/pubmed/26702323
http://dx.doi.org/10.1016/j.joa.2015.05.002
work_keys_str_mv AT grandeantoninom aorticperforationduetocardiacresynchronisationtherapydefibrillatorleadplacementcasereportandmedicolegalconsiderations
AT fioreantonio aorticperforationduetocardiacresynchronisationtherapydefibrillatorleadplacementcasereportandmedicolegalconsiderations
AT merlanomaurizio aorticperforationduetocardiacresynchronisationtherapydefibrillatorleadplacementcasereportandmedicolegalconsiderations
AT buzzifabio aorticperforationduetocardiacresynchronisationtherapydefibrillatorleadplacementcasereportandmedicolegalconsiderations
AT mazzolaalessandro aorticperforationduetocardiacresynchronisationtherapydefibrillatorleadplacementcasereportandmedicolegalconsiderations