Frame-Based Stereotactic Biopsy of Canine Brain Masses: Technique and Clinical Results in 26 Cases

This report describes the methodology, diagnostic yield, and adverse events (AE) associated with frame-based stereotactic brain biopsies (FBSB) obtained from 26 dogs with solitary forebrain lesions. Medical records were reviewed from dogs that underwent FBSB using two stereotactic headframes designe...

Descripción completa

Detalles Bibliográficos
Autores principales: Rossmeisl, John Henry, Andriani, Rudy T., Cecere, Thomas E., Lahmers, Kevin, LeRoith, Tanya, Zimmerman, Kurt L., Gibo, Denise, Debinski, Waldemar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4672202/
https://www.ncbi.nlm.nih.gov/pubmed/26664949
http://dx.doi.org/10.3389/fvets.2015.00020
_version_ 1782404525942898688
author Rossmeisl, John Henry
Andriani, Rudy T.
Cecere, Thomas E.
Lahmers, Kevin
LeRoith, Tanya
Zimmerman, Kurt L.
Gibo, Denise
Debinski, Waldemar
author_facet Rossmeisl, John Henry
Andriani, Rudy T.
Cecere, Thomas E.
Lahmers, Kevin
LeRoith, Tanya
Zimmerman, Kurt L.
Gibo, Denise
Debinski, Waldemar
author_sort Rossmeisl, John Henry
collection PubMed
description This report describes the methodology, diagnostic yield, and adverse events (AE) associated with frame-based stereotactic brain biopsies (FBSB) obtained from 26 dogs with solitary forebrain lesions. Medical records were reviewed from dogs that underwent FBSB using two stereotactic headframes designed for use in small animals and compatible with computed tomographic (CT) and magnetic resonance (MR) imaging. Stereotactic plans were generated from MR and CT images using commercial software, and FBSB performed both with (14/26) and without intraoperative image guidance. Records were reviewed for diagnostic yield, defined as the proportion of biopsies producing a specific neuropathological diagnosis, AE associated with FBSB, and risk factors for the development of AE. Postprocedural AE were evaluated in 19/26 dogs that did not proceed to a therapeutic intervention immediately following biopsy. Biopsy targets included intra-axial telencephalic masses (24/26), one intra-axial diencephalic mass, and one extra-axial parasellar mass. The median target volume was 1.99 cm(3). No differences in patient, lesion, or outcome variables were observed between the two headframe systems used or between FBSB performed with or without intraoperative CT guidance. The diagnostic yield of FBSB was 94.6%. Needle placement error was a significant risk factor associated with procurement of non-diagnostic biopsy specimens. Gliomas were diagnosed in 24/26 dogs, and meningioma and granulomatous meningoencephalitis in 1 dog each. AE directly related to FBSB were observed in a total of 7/26 (27%) of dogs. Biopsy-associated clinical morbidity, manifesting as seizures and transient neurological deterioration, occurred in 3/19 (16%) of dogs. The case fatality rate was 5.2% (1/19 dogs), with death attributable to intracranial hemorrhage. FBSB using the described apparatus was relatively safe and effective at providing neuropathological diagnoses in dogs with focal forebrain lesions.
format Online
Article
Text
id pubmed-4672202
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-46722022015-12-10 Frame-Based Stereotactic Biopsy of Canine Brain Masses: Technique and Clinical Results in 26 Cases Rossmeisl, John Henry Andriani, Rudy T. Cecere, Thomas E. Lahmers, Kevin LeRoith, Tanya Zimmerman, Kurt L. Gibo, Denise Debinski, Waldemar Front Vet Sci Veterinary Science This report describes the methodology, diagnostic yield, and adverse events (AE) associated with frame-based stereotactic brain biopsies (FBSB) obtained from 26 dogs with solitary forebrain lesions. Medical records were reviewed from dogs that underwent FBSB using two stereotactic headframes designed for use in small animals and compatible with computed tomographic (CT) and magnetic resonance (MR) imaging. Stereotactic plans were generated from MR and CT images using commercial software, and FBSB performed both with (14/26) and without intraoperative image guidance. Records were reviewed for diagnostic yield, defined as the proportion of biopsies producing a specific neuropathological diagnosis, AE associated with FBSB, and risk factors for the development of AE. Postprocedural AE were evaluated in 19/26 dogs that did not proceed to a therapeutic intervention immediately following biopsy. Biopsy targets included intra-axial telencephalic masses (24/26), one intra-axial diencephalic mass, and one extra-axial parasellar mass. The median target volume was 1.99 cm(3). No differences in patient, lesion, or outcome variables were observed between the two headframe systems used or between FBSB performed with or without intraoperative CT guidance. The diagnostic yield of FBSB was 94.6%. Needle placement error was a significant risk factor associated with procurement of non-diagnostic biopsy specimens. Gliomas were diagnosed in 24/26 dogs, and meningioma and granulomatous meningoencephalitis in 1 dog each. AE directly related to FBSB were observed in a total of 7/26 (27%) of dogs. Biopsy-associated clinical morbidity, manifesting as seizures and transient neurological deterioration, occurred in 3/19 (16%) of dogs. The case fatality rate was 5.2% (1/19 dogs), with death attributable to intracranial hemorrhage. FBSB using the described apparatus was relatively safe and effective at providing neuropathological diagnoses in dogs with focal forebrain lesions. Frontiers Media S.A. 2015-07-27 /pmc/articles/PMC4672202/ /pubmed/26664949 http://dx.doi.org/10.3389/fvets.2015.00020 Text en Copyright © 2015 Rossmeisl, Andriani, Cecere, Lahmers, LeRoith, Zimmerman, Gibo and Debinski. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Veterinary Science
Rossmeisl, John Henry
Andriani, Rudy T.
Cecere, Thomas E.
Lahmers, Kevin
LeRoith, Tanya
Zimmerman, Kurt L.
Gibo, Denise
Debinski, Waldemar
Frame-Based Stereotactic Biopsy of Canine Brain Masses: Technique and Clinical Results in 26 Cases
title Frame-Based Stereotactic Biopsy of Canine Brain Masses: Technique and Clinical Results in 26 Cases
title_full Frame-Based Stereotactic Biopsy of Canine Brain Masses: Technique and Clinical Results in 26 Cases
title_fullStr Frame-Based Stereotactic Biopsy of Canine Brain Masses: Technique and Clinical Results in 26 Cases
title_full_unstemmed Frame-Based Stereotactic Biopsy of Canine Brain Masses: Technique and Clinical Results in 26 Cases
title_short Frame-Based Stereotactic Biopsy of Canine Brain Masses: Technique and Clinical Results in 26 Cases
title_sort frame-based stereotactic biopsy of canine brain masses: technique and clinical results in 26 cases
topic Veterinary Science
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4672202/
https://www.ncbi.nlm.nih.gov/pubmed/26664949
http://dx.doi.org/10.3389/fvets.2015.00020
work_keys_str_mv AT rossmeisljohnhenry framebasedstereotacticbiopsyofcaninebrainmassestechniqueandclinicalresultsin26cases
AT andrianirudyt framebasedstereotacticbiopsyofcaninebrainmassestechniqueandclinicalresultsin26cases
AT cecerethomase framebasedstereotacticbiopsyofcaninebrainmassestechniqueandclinicalresultsin26cases
AT lahmerskevin framebasedstereotacticbiopsyofcaninebrainmassestechniqueandclinicalresultsin26cases
AT leroithtanya framebasedstereotacticbiopsyofcaninebrainmassestechniqueandclinicalresultsin26cases
AT zimmermankurtl framebasedstereotacticbiopsyofcaninebrainmassestechniqueandclinicalresultsin26cases
AT gibodenise framebasedstereotacticbiopsyofcaninebrainmassestechniqueandclinicalresultsin26cases
AT debinskiwaldemar framebasedstereotacticbiopsyofcaninebrainmassestechniqueandclinicalresultsin26cases