Cargando…

Performance of the forward-view echoendoscope for pancreaticobiliary examination in patients with status post-upper gastrointestinal surgery

BACKGROUND AND OBJECTIVES: Failures of endoscopic ultrasound (EUS) imaging of the head of the pancreas (HOP) and the common bile duct (CBD) have been reported in up to 50% of patients with status postsurgery (e.g., Billroth II and Roux-en-Y). This is attributable to inability to intubate the afferen...

Descripción completa

Detalles Bibliográficos
Autores principales: Fusaroli, Pietro, Serrani, Marta, Lisotti, Andrea, D’Ercole, Maria Cristina, Ceroni, Liza, Caletti, Giancarlo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4672593/
https://www.ncbi.nlm.nih.gov/pubmed/26643703
http://dx.doi.org/10.4103/2303-9027.170427
_version_ 1782404601192906752
author Fusaroli, Pietro
Serrani, Marta
Lisotti, Andrea
D’Ercole, Maria Cristina
Ceroni, Liza
Caletti, Giancarlo
author_facet Fusaroli, Pietro
Serrani, Marta
Lisotti, Andrea
D’Ercole, Maria Cristina
Ceroni, Liza
Caletti, Giancarlo
author_sort Fusaroli, Pietro
collection PubMed
description BACKGROUND AND OBJECTIVES: Failures of endoscopic ultrasound (EUS) imaging of the head of the pancreas (HOP) and the common bile duct (CBD) have been reported in up to 50% of patients with status postsurgery (e.g., Billroth II and Roux-en-Y). This is attributable to inability to intubate the afferent limb or the duodenum. Recently, a forward-view (FV) echoendoscope has become available. The frontal endoscopic and ultrasound field of view theoretically allow easier manipulation throughout the gastrointestinal tract compared to the traditional echoendoscopes. The aim of our study was to evaluate the safety and performance of the FV echoendoscope for the investigation of the biliary tree and the pancreas, including fine-needle aspiration (FNA), in patients with surgically altered upper gastrointestinal anatomy. PATIENTS AND METHODS: This was a retrospective evaluation of a prospectively maintained database. All EUS procedures were performed at our institution by one experienced endosonographer from March to September 2009 under conscious sedation. The FV echoendoscope was used for all procedures. RESULTS: Twenty-five (25) out of 37 presented status post-Billroth II and 12 out of 37 with status post-Roux-en-Y surgery. Overall, HOP and CBD were adequately visualized in 28 out of 37 (75.7%). All the failures occurred in the Roux-en-Y patients. EUS-FNA was successfully performed in 16 patients. No adverse events were observed. CONCLUSIONS: The FV echoendoscope proved to be safe and effective in reaching the periampullary area in patients with previous Billroth II, allowing complete exploration of the HOP and the CBD and performance of EUS-FNA. However, FV EUS was unsuccessful in the majority of patients with Roux-en-Y, which still remains a challenging condition.
format Online
Article
Text
id pubmed-4672593
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-46725932015-12-17 Performance of the forward-view echoendoscope for pancreaticobiliary examination in patients with status post-upper gastrointestinal surgery Fusaroli, Pietro Serrani, Marta Lisotti, Andrea D’Ercole, Maria Cristina Ceroni, Liza Caletti, Giancarlo Endosc Ultrasound Original Article BACKGROUND AND OBJECTIVES: Failures of endoscopic ultrasound (EUS) imaging of the head of the pancreas (HOP) and the common bile duct (CBD) have been reported in up to 50% of patients with status postsurgery (e.g., Billroth II and Roux-en-Y). This is attributable to inability to intubate the afferent limb or the duodenum. Recently, a forward-view (FV) echoendoscope has become available. The frontal endoscopic and ultrasound field of view theoretically allow easier manipulation throughout the gastrointestinal tract compared to the traditional echoendoscopes. The aim of our study was to evaluate the safety and performance of the FV echoendoscope for the investigation of the biliary tree and the pancreas, including fine-needle aspiration (FNA), in patients with surgically altered upper gastrointestinal anatomy. PATIENTS AND METHODS: This was a retrospective evaluation of a prospectively maintained database. All EUS procedures were performed at our institution by one experienced endosonographer from March to September 2009 under conscious sedation. The FV echoendoscope was used for all procedures. RESULTS: Twenty-five (25) out of 37 presented status post-Billroth II and 12 out of 37 with status post-Roux-en-Y surgery. Overall, HOP and CBD were adequately visualized in 28 out of 37 (75.7%). All the failures occurred in the Roux-en-Y patients. EUS-FNA was successfully performed in 16 patients. No adverse events were observed. CONCLUSIONS: The FV echoendoscope proved to be safe and effective in reaching the periampullary area in patients with previous Billroth II, allowing complete exploration of the HOP and the CBD and performance of EUS-FNA. However, FV EUS was unsuccessful in the majority of patients with Roux-en-Y, which still remains a challenging condition. Medknow Publications & Media Pvt Ltd 2015 /pmc/articles/PMC4672593/ /pubmed/26643703 http://dx.doi.org/10.4103/2303-9027.170427 Text en Copyright: © 2015 Spring Media Publishing Co. Ltd http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Fusaroli, Pietro
Serrani, Marta
Lisotti, Andrea
D’Ercole, Maria Cristina
Ceroni, Liza
Caletti, Giancarlo
Performance of the forward-view echoendoscope for pancreaticobiliary examination in patients with status post-upper gastrointestinal surgery
title Performance of the forward-view echoendoscope for pancreaticobiliary examination in patients with status post-upper gastrointestinal surgery
title_full Performance of the forward-view echoendoscope for pancreaticobiliary examination in patients with status post-upper gastrointestinal surgery
title_fullStr Performance of the forward-view echoendoscope for pancreaticobiliary examination in patients with status post-upper gastrointestinal surgery
title_full_unstemmed Performance of the forward-view echoendoscope for pancreaticobiliary examination in patients with status post-upper gastrointestinal surgery
title_short Performance of the forward-view echoendoscope for pancreaticobiliary examination in patients with status post-upper gastrointestinal surgery
title_sort performance of the forward-view echoendoscope for pancreaticobiliary examination in patients with status post-upper gastrointestinal surgery
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4672593/
https://www.ncbi.nlm.nih.gov/pubmed/26643703
http://dx.doi.org/10.4103/2303-9027.170427
work_keys_str_mv AT fusarolipietro performanceoftheforwardviewechoendoscopeforpancreaticobiliaryexaminationinpatientswithstatuspostuppergastrointestinalsurgery
AT serranimarta performanceoftheforwardviewechoendoscopeforpancreaticobiliaryexaminationinpatientswithstatuspostuppergastrointestinalsurgery
AT lisottiandrea performanceoftheforwardviewechoendoscopeforpancreaticobiliaryexaminationinpatientswithstatuspostuppergastrointestinalsurgery
AT dercolemariacristina performanceoftheforwardviewechoendoscopeforpancreaticobiliaryexaminationinpatientswithstatuspostuppergastrointestinalsurgery
AT ceroniliza performanceoftheforwardviewechoendoscopeforpancreaticobiliaryexaminationinpatientswithstatuspostuppergastrointestinalsurgery
AT calettigiancarlo performanceoftheforwardviewechoendoscopeforpancreaticobiliaryexaminationinpatientswithstatuspostuppergastrointestinalsurgery